{"id":13655,"date":"2026-10-20T18:31:52","date_gmt":"2026-10-20T10:31:52","guid":{"rendered":"https:\/\/www.daelimtransformer.com\/?p=13655"},"modified":"2026-10-24T21:17:38","modified_gmt":"2026-10-24T13:17:38","slug":"transformer-bushing-guide","status":"publish","type":"post","link":"https:\/\/www.daelimtransformer.com\/de\/transformer-bushing-guide\/","title":{"rendered":"Transformator-Durchf\u00fchrungen: Typen, Aufbau, Funktionsweise und Anwendungsbereiche"},"content":{"rendered":"<figure class=\"wp-block-image size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1500\" height=\"627\" src=\"https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/10\/transformer-bushing.webp\" alt=\"Transformatordurchf\u00fchrung\" class=\"wp-image-13677\" srcset=\"https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/10\/transformer-bushing.webp 1500w, https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/10\/transformer-bushing-768x321.webp 768w, https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/10\/transformer-bushing-18x8.webp 18w, https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/10\/transformer-bushing-598x250.webp 598w\" sizes=\"(max-width: 1500px) 100vw, 1500px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Elektrische Transformatoren sind beeindruckende Ger\u00e4te, die mithilfe der in ihrem Geh\u00e4use befindlichen Komponenten elektrische Leistung im Megawattbereich regulieren. Transformator-Durchf\u00fchrungen dienen dazu, diese internen Komponenten sicher mit externen Stromkreisen zu verbinden.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In diesem Artikel werden wir uns sehr ausf\u00fchrlich mit Transformator-Durchf\u00fchrungen befassen. Wir werden untersuchen, was eine Durchf\u00fchrung ist, welche verschiedenen Bauarten es gibt und nach welchem Prinzip sie funktioniert.<\/p>\n\n\n\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button quoteModal\"><a class=\"wp-block-button__link wp-element-button\">Kontaktieren Sie Daelim Transformer<\/a><\/div>\n<\/div>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"What_is_Transformer_Bushing\"><\/span>Was ist eine Transformator-Durchf\u00fchrung?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Die Durchf\u00fchrung des elektrischen Transformators ist ein entscheidendes Isolierbauteil des elektrischen Transformators. Sie erm\u00f6glicht es, elektrische Anschl\u00fcsse sicher und zuverl\u00e4ssig durch den geerdeten Transformatorbeh\u00e4lter zu f\u00fchren, um interne und externe Teile miteinander zu verbinden.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Entsprechend der Konstruktion und Funktionsweise eines elektrischen Transformators ist der Transformatorbeh\u00e4lter aus Sicherheitsgr\u00fcnden geerdet. Die Transformator-Durchf\u00fchrung sorgt f\u00fcr die erforderliche elektrische Isolierung, mechanische Abst\u00fctzung und Feldsteuerung, um eine zuverl\u00e4ssige Verbindung zwischen den externen und internen elektrischen Komponenten des Transformators zu gew\u00e4hrleisten.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"How_Transformer_Bushing_Works\"><\/span>Wie funktioniert eine Transformator-Durchf\u00fchrung?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Bei elektrischen Transformatoren muss ein stromf\u00fchrender Leiter (in der Regel Kupferdr\u00e4hte oder -b\u00e4nder) geerdete metallische Transformatorbeh\u00e4lter durchqueren. Die Durchf\u00fchrung erm\u00f6glicht diese Verbindung auf sichere und zuverl\u00e4ssige Weise, indem sie den Leiter in einer sorgf\u00e4ltig konstruierten <a href=\"https:\/\/www.daelimtransformer.com\/de\/transformer-insulation.html\">D\u00e4mmsystem<\/a>. Das System ist so ausgelegt, dass jeglicher Stromverlust aus eingehenden oder ausgehenden Stromleitungen verhindert wird.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Die Durchf\u00fchrungen sind so konstruiert, dass das Leitermaterial im Zentrum verbleibt, w\u00e4hrend der umgebende Teil der Durchf\u00fchrung aus hochwertigem Isoliermaterial besteht. Dieses Isoliermaterial gew\u00e4hrleistet eine ausreichende Durchschlagfestigkeit zwischen dem Leiter und dem geerdeten Beh\u00e4lter.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Transformer_Bushing_Diagram\"><\/span>Schema der Transformator-Durchf\u00fchrungen<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<div class=\"wp-block-media-text has-media-on-the-right is-stacked-on-mobile\"><div class=\"wp-block-media-text__content\">\n<p class=\"wp-block-paragraph\">Eine herk\u00f6mmliche Transformator-Durchf\u00fchrung besteht aus f\u00fcnf Hauptkomponenten. Die erste und wichtigste Komponente der Transformator-Durchf\u00fchrung ist der zentrale stromf\u00fchrende Leiter. Er ist das Bauteil, das die externen und internen elektrischen Komponenten miteinander verbindet.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Dieser stromf\u00fchrende Leiter ist von der Isolierfl\u00fcssigkeit oder einem festen Isolator umgeben, der als internes Isolationssystem bezeichnet wird. Das interne Isolationssystem stellt sicher, dass das Verbindungsmaterial ordnungsgem\u00e4\u00df von allen anderen Teilen der Durchf\u00fchrung und des Transformatorbeh\u00e4lters isoliert ist.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Das interne Isolationssystem befindet sich im Inneren des Durchf\u00fchrungsgeh\u00e4uses, das als \u00e4u\u00dferes Isolationsgeh\u00e4use bezeichnet wird. Das \u00e4u\u00dfere Geh\u00e4use ist f\u00fcr die Gesamtisolierung der Anlage verantwortlich. Es stellt sicher, dass kein Strom aus dem Transformator in das leitende Material entweicht, das durch die Durchf\u00fchrung verl\u00e4uft.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Die Transformator-Durchf\u00fchrung verf\u00fcgt au\u00dferdem \u00fcber Flansche zur Befestigung und Erdung der Durchf\u00fchrung. Um die internen elektrischen Komponenten des Transformators mit der externen elektrischen Anlage zu verbinden, verf\u00fcgt die Durchf\u00fchrung \u00fcber Anschl\u00fcsse, sodass eine ordnungsgem\u00e4\u00dfe elektrische Verbindung hergestellt werden kann.<\/p>\n<\/div><figure class=\"wp-block-media-text__media\"><img decoding=\"async\" width=\"1024\" height=\"1536\" src=\"https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/10\/transformer-bushing-diagram.webp\" alt=\"Beschriftete Darstellung einer Transformator-Durchf\u00fchrung mit dem oberen Anschluss, dem Wetterschutzisolator, dem Leiter, dem Kondensatorkern, dem Pr\u00fcfanschluss, der \u00d6lf\u00fcllung, dem \u00d6lendisolator, dem Befestigungsflansch und den Dichtungen\" class=\"wp-image-13656 size-full\" srcset=\"https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/10\/transformer-bushing-diagram.webp 1024w, https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/10\/transformer-bushing-diagram-768x1152.webp 768w, https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/10\/transformer-bushing-diagram-8x12.webp 8w, https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/10\/transformer-bushing-diagram-600x900.webp 600w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure><\/div>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Importance_of_Bushing_Insulation_Grading_System\"><\/span>Bedeutung des Klassifizierungssystems f\u00fcr die Isolierung von Durchf\u00fchrungen<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Bei Arbeiten an Transformator-Durchf\u00fchrungen f\u00fchrt ein Anstieg der elektrischen Spannung zu einer Zunahme dieser durch das elektrische Feld erzeugten Spannungen. Bei h\u00f6heren Spannungen werden diese Spannungen ungleichm\u00e4\u00dfig verteilt und konzentrieren sich stark in der N\u00e4he des Leiters.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Um dies zu kontrollieren, werden moderne Maschinen mit abgestuften Isolationssystemen hergestellt, die die elektrische Feldst\u00e4rke regulieren und eine lokale \u00dcberbeanspruchung verhindern k\u00f6nnen.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Dieses Isolationsklassifizierungssystem gew\u00e4hrleistet, dass die Durchf\u00fchrung des elektrischen Transformators folgende Eigenschaften aufweist:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Gleichm\u00e4\u00dfige Spannungsverteilung im Durchf\u00fchrungsbereich, wenn Hochspannungsstrom durch die Durchf\u00fchrung flie\u00dft<\/li>\n\n\n\n<li>Es sorgt f\u00fcr eine geringere Teilentladungsaktivit\u00e4t im Bereich der Transformator-Durchf\u00fchrungen.<\/li>\n\n\n\n<li>Au\u00dferdem verhindert es die Zersetzung des Isoliermaterials und sorgt f\u00fcr eine l\u00e4ngere Lebensdauer der Durchf\u00fchrungen.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Durch eine gleichm\u00e4\u00dfige Spannungsverteilung werden Teilentladungen reduziert und die Lebensdauer der Durchf\u00fchrungen verl\u00e4ngert. Die Isolationsklassifizierungssysteme sorgen f\u00fcr eine verbesserte Betriebssicherheit des elektrischen Transformators und der Transformator-Durchf\u00fchrungen.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Transformer_Bushing_Material\"><\/span>Material f\u00fcr Transformator-Durchf\u00fchrungen<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Elektrische Transformator-Durchf\u00fchrungen werden aus einer Vielzahl von Werkstoffen hergestellt. Die Wahl des Werkstoffs h\u00e4ngt weitgehend von der Konstruktion der Durchf\u00fchrung und dem Einsatzzweck ab, f\u00fcr den sie vorgesehen ist. Wir haben alle m\u00f6glichen Werkstoffe, die bei der Herstellung von Transformator-Durchf\u00fchrungen zum Einsatz kommen, ausf\u00fchrlich behandelt.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Porcelain_Bushings\"><\/span>Porzellanbuchsen<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1170\" height=\"917\" src=\"https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/10\/Porcelain-Bushings.webp\" alt=\"Porzellanbuchsen\" class=\"wp-image-13675\" srcset=\"https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/10\/Porcelain-Bushings.webp 1170w, https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/10\/Porcelain-Bushings-767x601.webp 767w, https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/10\/Porcelain-Bushings-15x12.webp 15w, https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/10\/Porcelain-Bushings-600x470.webp 600w\" sizes=\"(max-width: 1170px) 100vw, 1170px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Das am h\u00e4ufigsten verwendete Zusatzmaterial bei der Herstellung von Transformator-Durchf\u00fchrungen ist Porzellan. Diese Porzellan-Durchf\u00fchrungen werden traditionell in allen Anwendungsbereichen eingesetzt, in denen eine hohe mechanische Festigkeit bei hervorragenden dielektrischen Eigenschaften erforderlich ist. Sie sind bekannt f\u00fcr ihre lange Lebensdauer; allerdings ist Porzellan ein spr\u00f6des Material, und es kann zu katastrophalen Ausf\u00e4llen kommen, wenn die mechanische Belastung seine Bruchgrenze \u00fcberschreitet.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Polymer_and_Composite_Materials\"><\/span>Polymere und Verbundwerkstoffe<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1300\" height=\"975\" src=\"https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/10\/Polymer-and-Composite-bushing.webp\" alt=\"Buchsen aus Polymer und Verbundwerkstoff\" class=\"wp-image-13681\" srcset=\"https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/10\/Polymer-and-Composite-bushing.webp 1300w, https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/10\/Polymer-and-Composite-bushing-16x12.webp 16w, https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/10\/Polymer-and-Composite-bushing-768x576.webp 768w, https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/10\/Polymer-and-Composite-bushing-600x450.webp 600w\" sizes=\"(max-width: 1300px) 100vw, 1300px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Um das Problem katastrophaler Ausf\u00e4lle bei Porzellanbuchsen zu beheben, wurden Polymere und Verbundwerkstoffe in die Buchsenherstellung eingef\u00fchrt. Diese Polymere und Verbundwerkstoffe sind sehr leicht und weisen eine hervorragende Best\u00e4ndigkeit gegen alle Arten von elektrischen und thermischen Belastungen auf. Die Polymere und Verbundwerkstoffe zeichnen sich durch eine deutlich bessere Verschmutzungsbest\u00e4ndigkeit aus und sind widerstandsf\u00e4hig gegen alle Arten von Vandalismus und Rissbildung.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Bushing_Internal_Insulation_Materials\"><\/span>Isoliermaterialien f\u00fcr Buchseninnenseiten<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Zur Herstellung der \u00e4u\u00dferen oder Gesamtform der Buchse werden Porzellan sowie Polymer- oder Verbundwerkstoffe verwendet. Auch die inneren Bestandteile der Buchse m\u00fcssen isoliert werden, wof\u00fcr separates Buchsenmaterial zum Einsatz kommt.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Zu den Materialien f\u00fcr Innenbuchsen geh\u00f6ren<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Mit \u00d6l getr\u00e4nktes Papier<\/li>\n\n\n\n<li>Mit Harz impr\u00e4gniertes Papier<\/li>\n\n\n\n<li>Synthetisches D\u00e4mmmaterial<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Bushing_Material_Selection_Criteria\"><\/span>Kriterien f\u00fcr die Materialauswahl von Buchsen<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Die Kriterien f\u00fcr die Materialauswahl der Transformator-Durchf\u00fchrung h\u00e4ngen von einer Reihe von Faktoren ab, darunter unter anderem:;<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Typ, Bauart, Gr\u00f6\u00dfe und Nennleistung von elektrischen Transformatoren<\/li>\n\n\n\n<li>Der maximale Spannungspegel, der unter Spitzenlastbedingungen auftreten kann<\/li>\n\n\n\n<li>Die nationalen und internationalen Normen und Gesetze zur Regelung von Transformatoren und deren Konstruktion<\/li>\n\n\n\n<li>Die Umgebungsbedingungen, unter denen die Durchf\u00fchrungen eingebaut werden<\/li>\n\n\n\n<li>Jede Art von mechanischer Belastung der Transformator-Durchf\u00fchrung<\/li>\n\n\n\n<li>Die Wartungskriterien und die Gesamtprojektkosten<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Types_of_Transformer_Bushing\"><\/span>Arten von Transformator-Durchf\u00fchrungen<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Je nach Anwendungsbereich und Typ des elektrischen Transformators gibt es verschiedene Arten von Transformator-Durchf\u00fchrungen, die speziell f\u00fcr die jeweiligen Anforderungen entwickelt wurden. Dar\u00fcber hinaus kann jeder Transformator je nach Bauart und Einsatzzweck \u00fcber mehr als eine Durchf\u00fchrung verf\u00fcgen. Im Folgenden werden einige der grundlegenden Typen von Transformator-Durchf\u00fchrungen vorgestellt.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"High_Voltage_Bushing\"><\/span>Hochvoltstecker<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1183\" height=\"745\" src=\"https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/10\/High-Voltage-Bushing.webp\" alt=\"Hochvoltstecker\" class=\"wp-image-13676\" srcset=\"https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/10\/High-Voltage-Bushing.webp 1183w, https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/10\/High-Voltage-Bushing-767x483.webp 767w, https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/10\/High-Voltage-Bushing-18x11.webp 18w, https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/10\/High-Voltage-Bushing-599x377.webp 599w\" sizes=\"(max-width: 1183px) 100vw, 1183px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Hochspannungsdurchf\u00fchrungen werden am Hochspannungsanschluss bzw. auf der Hochspannungsseite des elektrischen Transformators eingesetzt. Diese Durchf\u00fchrungen verf\u00fcgen \u00fcber eine kondensatorartige Isolierung und sind so ausgelegt, dass sie das elektrische Feld kontrollieren und somit hohen elektrischen Belastungen standhalten.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Low_Voltage_Bushing\"><\/span>Niederspannungsdurchf\u00fchrung<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1300\" height=\"893\" src=\"https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/10\/Low-Voltage-Bushing.webp\" alt=\"Niederspannungsdurchf\u00fchrung\" class=\"wp-image-13680\" srcset=\"https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/10\/Low-Voltage-Bushing.webp 1300w, https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/10\/Low-Voltage-Bushing-17x12.webp 17w, https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/10\/Low-Voltage-Bushing-767x527.webp 767w, https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/10\/Low-Voltage-Bushing-600x412.webp 600w\" sizes=\"(max-width: 1300px) 100vw, 1300px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Niederspannungsdurchf\u00fchrungen oder der Einsatz von Durchf\u00fchrungen auf der Niederspannungsseite des elektrischen Transformators. Aufgrund der Niederspannungsanwendungen sind diese Durchf\u00fchrungen recht einfach aufgebaut und stellen im Grunde solide dielektrische Durchf\u00fchrungen dar, die relativ geringen chemischen Belastungen ausgesetzt sind.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Neutral_Bushing\"><\/span>Neutrale Buchse<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Neutrale Durchf\u00fchrungen sind ein wesentlicher Bestandteil von elektrischen Transformatoren und werden, \u00e4hnlich wie Niederspannungsdurchf\u00fchrungen, bei relativ niedrigen Spannungen eingesetzt. Diese Durchf\u00fchrungen sind f\u00fcr Erdungssysteme und das Fehlerstrommanagement unverzichtbar.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Dead_Front_Bushing\"><\/span>Isolator mit toter Vorderseite<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1920\" height=\"1280\" src=\"https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/10\/dead-front-bushing.webp\" alt=\"\" class=\"wp-image-13682\" srcset=\"https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/10\/dead-front-bushing.webp 1920w, https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/10\/dead-front-bushing-18x12.webp 18w, https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/10\/dead-front-bushing-768x512.webp 768w, https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/10\/dead-front-bushing-600x400.webp 600w, https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/10\/dead-front-bushing-1536x1024.webp 1536w\" sizes=\"(max-width: 1920px) 100vw, 1920px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Eine \u201eDead-Front\u201c-Buchse ist eine spezielle Art von Buchse, die speziell f\u00fcr die <a href=\"https:\/\/www.daelimtransformer.com\/de\/pad-mounted-transformer.html\"><strong>Transformatoren mit Sockel<\/strong><\/a>. Bei diesen Buchsen sind alle elektrisch leitenden Teile durch Gummi oder ein epoxidharz\u00e4hnliches Material gut isoliert.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Dies erh\u00f6ht die Sicherheit erheblich, minimiert das Unfallrisiko und erleichtert die Inspektion und den Austausch in dicht best\u00fcckten Anlagen. \u201eDead-Front\u201c-Durchf\u00fchrungen sind die g\u00e4ngige Wahl bei Transformatoren, die f\u00fcr den amerikanischen Markt konzipiert und entwickelt wurden.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Live_Front_Bushing\"><\/span>Isolator mit lebender Vorderseite<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1536\" height=\"818\" src=\"https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/10\/live-front-bushing.webp\" alt=\"Live-Frontbuchse\" class=\"wp-image-13684\" srcset=\"https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/10\/live-front-bushing.webp 1536w, https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/10\/live-front-bushing-18x10.webp 18w, https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/10\/live-front-bushing-768x409.webp 768w, https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/10\/live-front-bushing-599x319.webp 599w\" sizes=\"(max-width: 1536px) 100vw, 1536px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Die \u201eLive Front\u201c-Buchse ist eine speziell entwickelte Buchsenkonstruktion, die f\u00fcr <a href=\"https:\/\/www.daelimtransformer.com\/de\/live-front-pad-mounted-transformer.html\"><strong>Transformatoren in offener Ausf\u00fchrung<\/strong><\/a>. Diese Buchsen verf\u00fcgen \u00fcber freiliegende Anschl\u00fcsse, die zwar das Unfallrisiko erh\u00f6hen, jedoch wesentlich einfacher zu handhaben sind und weniger kosten. Bei der Arbeit mit diesen Buchsen m\u00fcssen Sicherheitsstandards und -verfahren strikt eingehalten werden.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Plug_in_Bushing\"><\/span>Steckbuchse<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Steckbare Transformator-Durchf\u00fchrungen sind moderne Alternativen zu Durchf\u00fchrungen mit isolierter und spannungsf\u00fchrender Vorderseite. Sie stellen zudem eine sichere Alternative zu herk\u00f6mmlichen Durchf\u00fchrungen dar und sind f\u00fcr den schnellen Anschluss mittels eines abgeschirmten, trennbaren Steckverbinders ausgelegt. Bei Transformatoren, die f\u00fcr den europ\u00e4ischen Markt oder nach europ\u00e4ischen Normen konzipiert und entwickelt wurden, wird dieser Stecktyp bevorzugt.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Solid_Bushings\"><\/span>Massive Buchsen<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Massive Durchf\u00fchrungen geh\u00f6ren zu den traditionellsten Ausf\u00fchrungen von Durchf\u00fchrungen, bei deren Herstellung in der Regel ein homogenes Isoliermaterial zum Einsatz kommt. Diese Durchf\u00fchrungen sind f\u00fcr Niederspannungsanwendungen konzipiert und entwickelt worden.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Condenser_Bushing\"><\/span>Kondensator-Durchf\u00fchrung<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Die Kondensator-Durchf\u00fchrung wird f\u00fcr Hochspannungsanwendungen eingesetzt. Diese Durchf\u00fchrungen wurden mit leitf\u00e4higen Schichten konstruiert und entwickelt, um das elektrische Feld zu gl\u00e4tten und die durch starke elektrische Felder verursachten Spannungen zu minimieren.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Types_of_Bushing_Terminals\"><\/span>Arten von H\u00fclsenklemmen<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Die Durchf\u00fchrungsanschl\u00fcsse des Transformators sind die Stellen, an denen die Durchf\u00fchrung mit dem elektrischen Transformator verbunden wird. Je nach Bauart gibt es drei Haupttypen von Durchf\u00fchrungsanschl\u00fcssen. Der erste Typ ist der Bolzenanschluss, der zweite Typ sind Palm-Anschl\u00fcsse und der dritte Typ ist der Klemmanschluss.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Diese Klemme stellt die mechanische und elektrische Verbindung zwischen dem elektrischen Transformator und der Transformator-Durchf\u00fchrung her. Diese Verbindung sollte daher sicherstellen, dass die Verbindung zwischen der Durchf\u00fchrung und dem Transformator<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Ordnungsgem\u00e4\u00df gesichert und mechanisch befestigt, sodass jede Art von mechanischer, thermischer und elektrischer Beanspruchung angemessen bew\u00e4ltigt werden kann<\/li>\n\n\n\n<li>Anschluss mit m\u00f6glichst geringem elektrischen Widerstand, da ein hoher Kontaktwiderstand zu \u00dcberhitzung f\u00fchren und einen Ausfall der Durchf\u00fchrung oder des Transformators verursachen kann.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Common_Transformer_Bushing_Failures_and_Maintenance\"><\/span>H\u00e4ufige Ausf\u00e4lle von Transformator-Durchf\u00fchrungen und deren Wartung<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Wie jede andere Komponente eines elektrischen Transformators ist auch die Transformator-Durchf\u00fchrung anf\u00e4llig f\u00fcr Ausf\u00e4lle und <a href=\"https:\/\/www.daelimtransformer.com\/de\/transformer-maintenance.html\">Wartungsprobleme<\/a> die f\u00fcr einen ordnungsgem\u00e4\u00dfen Betrieb des Transformators ber\u00fccksichtigt werden m\u00fcssen. Im Folgenden sind einige der h\u00e4ufigsten Ausf\u00e4lle von Transformator-Durchf\u00fchrungen sowie Wartungsma\u00dfnahmen aufgef\u00fchrt, die Sie durchf\u00fchren m\u00fcssen, um eine effiziente Leistung zu erzielen.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Partial_Discharge\"><\/span>Teilentladung<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Da die Transformator-Durchf\u00fchrung f\u00fcr die Isolierung der elektrischen Leiter konzipiert und entwickelt wurde, die in diese Transformatoren hinein- und aus ihnen herausf\u00fchren, geh\u00f6rt dies zu den h\u00e4ufigsten M\u00e4ngeln, die bei der Wartung des Transformators festgestellt werden. Die Durchf\u00fchrung versagt nicht vollst\u00e4ndig, sondern es wird davon ausgegangen, dass aufgrund kleinerer Defekte ein geringer elektrischer Strom austritt.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Insulation_Breakdown\"><\/span>Isolationsdurchschlag<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Ein weiterer sehr h\u00e4ufiger Ausfallgrund bei Transformator-Durchf\u00fchrungen ist der <a href=\"https:\/\/www.daelimtransformer.com\/de\/transformer-insulation-failure.html\">Isolationsdurchschlag<\/a>. Ein dauerhafter Ausfall der Isolierh\u00fclse, bei dem die Isolierh\u00fclse des Transformators die Isolierung des elektrischen Leiters, der in den elektrischen Transformator hinein- oder aus ihm herausf\u00fchrt, nicht mehr gew\u00e4hrleistet.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Der Isolationsdurchschlag wurde tats\u00e4chlich durch anhaltende elektrische und thermische Belastungen verursacht. Diese Belastungen entstehen durch \u00fcberm\u00e4\u00dfige Hitze im Transformator. Diese elektrischen und thermischen Belastungen k\u00f6nnen zu einem Versagen des dielektrischen Materials f\u00fchren.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Oil_Leakage_and_Moisture_Ingress\"><\/span>\u00d6laustritt und Eindringen von Feuchtigkeit<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Eine der Ausfallarten der Transformator-Durchf\u00fchrung tritt auf, wenn die Transformator-Durchf\u00fchrung beginnt <a href=\"https:\/\/www.daelimtransformer.com\/de\/transformer-oil-leaks.html\">aus dem die interne Isolier\u00f6l austritt<\/a>. Das \u00d6lleck ist tats\u00e4chlich entweder auf mangelhafte Fertigungsverfahren oder auf eine Besch\u00e4digung der Transformator-Durchf\u00fchrung zur\u00fcckzuf\u00fchren. Das aus der Transformator-Durchf\u00fchrung austretende \u00d6l erh\u00f6ht zudem die Gefahr des Eindringens von Feuchtigkeit, was zu einer Feuchtigkeitskontamination der Transformator-Durchf\u00fchrung f\u00fchrt.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Inspection_and_Diagnostic_Methods\"><\/span>Pr\u00fcf- und Diagnosemethoden<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Da die Transformator-Durchf\u00fchrung ein wesentlicher Bestandteil des elektrischen Transformators ist, werden im Rahmen der planm\u00e4\u00dfigen Wartung des elektrischen Transformators auch die Inspektion und die Diagnose der Transformator-Durchf\u00fchrung durchgef\u00fchrt. Es gibt vier verschiedene <a href=\"https:\/\/www.daelimtransformer.com\/de\/diagnostic-methods-for-power-transformer-insulation.html\">Diagnoseverfahren<\/a> an der Inspektion und Diagnose der Transformator-Durchf\u00fchrungen beteiligt und\/oder wie folgt.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Die Sichtpr\u00fcfung der Transformator-Durchf\u00fchrung dient dazu, etwaige \u00e4u\u00dferlich erkennbare Sch\u00e4den ausschlie\u00dflich am \u00e4u\u00dferen Teil der Transformator-Durchf\u00fchrung sowie jegliche Art von Leckagen der internen Isolierfl\u00fcssigkeit festzustellen.<\/li>\n\n\n\n<li>Die Infrarot-Thermografiepr\u00fcfung dient dazu, die Transformator-Durchf\u00fchrung thermisch zu untersuchen und Anzeichen einer \u00dcberhitzung zu erkennen, die die Transformator-Durchf\u00fchrung beeintr\u00e4chtigen k\u00f6nnten.<\/li>\n\n\n\n<li>An der Transformator-Durchf\u00fchrung wird eine Teilentladungspr\u00fcfung durchgef\u00fchrt, um eventuelle Stromlecks an der Durchf\u00fchrung festzustellen.<\/li>\n\n\n\n<li>Die Kapazit\u00e4ts- und Tangens-Delta-Messung dient dazu, die Isolationsf\u00e4higkeit der Transformator-Durchf\u00fchrung zu pr\u00fcfen, die den in den Transformatorbeh\u00e4lter hinein- oder aus ihm herausf\u00fchrenden elektrischen Leiter isoliert.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"FAQ\"><\/span><span id=\"FAQ\" class=\"ez-toc-section\"><\/span><strong>H\u00e4ufig gestellte Fragen<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<div class=\"saswp-faq-block-section\">\n<ol style=\"list-style-type: none;\">\n<li style=\"list-style-type: none;\">\n<h5 class=\"saswp-faq-question-title\"><span class=\"ez-toc-section\" id=\"Why_do_transformers_need_bushings\"><\/span><span id=\"Why_do_transformers_need_bushings\" class=\"ez-toc-section\"><\/span><strong>Warum ben\u00f6tigen Transformatoren Durchf\u00fchrungen?<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h5>\n<p class=\"saswp-faq-answer-text\">Elektrische Transformatoren ben\u00f6tigen Durchf\u00fchrungen, um eine isolierte elektrische Verbindung zwischen externen und internen elektrischen Bauteilen herzustellen. Au\u00dferdem dienen sie der mechanischen Abst\u00fctzung und der druckdichten Abdichtung der elektrischen Leiter.<\/p>\n<\/li>\n<li style=\"list-style-type: none;\">\n<h5 class=\"saswp-faq-question-title\"><span class=\"ez-toc-section\" id=\"What_causes_bushing_failure\"><\/span><span id=\"What_causes_bushing_failure\" class=\"ez-toc-section\"><\/span><strong>Was f\u00fchrt zum Ausfall von Buchsen?<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h5>\n<p class=\"saswp-faq-answer-text\">Faktoren wie das Eindringen von Feuchtigkeit, die Alterung der Isolierung, thermische Beanspruchung und Oberfl\u00e4chenverunreinigungen sind Hauptursachen, die zu einem vollst\u00e4ndigen Ausfall der Durchf\u00fchrung f\u00fchren k\u00f6nnen.<\/p>\n<\/li>\n<li style=\"list-style-type: none;\">\n<h5 class=\"saswp-faq-question-title\"><span class=\"ez-toc-section\" id=\"What_happens_when_a_bushing_fails\"><\/span><span id=\"What_happens_when_a_bushing_fails\" class=\"ez-toc-section\"><\/span><strong>Was passiert, wenn eine Buchse ausf\u00e4llt?<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h5>\n<p class=\"saswp-faq-answer-text\">Ein Ausfall einer Transformator-Durchf\u00fchrung kann zu einem vollst\u00e4ndigen oder teilweisen Ausfall des Transformators, zu Explosionen oder Br\u00e4nden am betroffenen Teil oder zumindest zu einer vor\u00fcbergehenden Unterbrechung der Stromversorgung f\u00fchren.<\/p>\n<\/li>\n<li style=\"list-style-type: none;\">\n<h5 class=\"saswp-faq-question-title\"><span class=\"ez-toc-section\" id=\"How_much_does_it_cost_to_replace_a_bushing\"><\/span><span id=\"How_much_does_it_cost_to_replace_a_bushing\" class=\"ez-toc-section\"><\/span><strong>Wie viel kostet der Austausch einer Buchse?<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h5>\n<p class=\"saswp-faq-answer-text\">Das h\u00e4ngt ganz von der Art, der Gr\u00f6\u00dfe und der Nennleistung des Transformators ab. Eine Niederspannungs-Verteiltransformator-Durchf\u00fchrung kann zwischen $100 und $350 pro St\u00fcck kosten, eine Hochspannungs-Durchf\u00fchrung zwischen einigen Tausend und $30.000. Bei den Gesamtkosten f\u00fcr den Austausch werden auch die Versand- und Installationskosten ber\u00fccksichtigt.<\/p>\n<\/li>\n<li style=\"list-style-type: none;\">\n<h5 class=\"saswp-faq-question-title\"><span class=\"ez-toc-section\" id=\"What_is_the_difference_between_a_transformer_bushing_and_an_insulator\"><\/span><span id=\"What_is_the_difference_between_a_transformer_bushing_and_an_insulator\" class=\"ez-toc-section\"><\/span><strong>Was ist der Unterschied zwischen einer Transformator-Durchf\u00fchrung und einem Isolator?<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h5>\n<p class=\"saswp-faq-answer-text\">Transformator-Durchf\u00fchrungen sind ein wesentlicher Bestandteil eines Transformators, da sie eine isolierte und sichere Verbindung zwischen den internen und externen elektrischen Bauteilen des Transformators gew\u00e4hrleisten. Der Begriff \u201eIsolator\u201c im weiteren Sinne bezieht sich hingegen auf das Material, das zur Isolierung interner Komponenten wie Wicklungen, Kern und anderer interner Teile verwendet wird.<\/p>\n<\/li>\n<li style=\"list-style-type: none;\">\n<h5 class=\"saswp-faq-question-title\"><span class=\"ez-toc-section\" id=\"What_are_the_signs_of_a_bad_transformer_bushing\"><\/span><span id=\"What_are_the_signs_of_a_bad_transformer_bushing\" class=\"ez-toc-section\"><\/span><strong>Was sind die Anzeichen f\u00fcr eine defekte Transformator-Durchf\u00fchrung?<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h5>\n<p class=\"saswp-faq-answer-text\">Die Transformator-Durchf\u00fchrung ist ein externes Bauteil, und Anzeichen f\u00fcr einen Defekt der Durchf\u00fchrung lassen sich bei einer Sichtpr\u00fcfung feststellen. Zu diesen Anzeichen z\u00e4hlen Risse an der Au\u00dfenfl\u00e4che, \u00d6laustritt, hohe Temperaturwerte bei der Thermografie sowie abnormale Messwerte bei der Kapazit\u00e4ts- und Tan-Delta-Pr\u00fcfung.<\/p>\n<\/li>\n<li style=\"list-style-type: none;\">\n<h5 class=\"saswp-faq-question-title\"><span class=\"ez-toc-section\" id=\"What_is_the_life_expectancy_of_a_transformer_bushing\"><\/span><span id=\"What_is_the_life_expectancy_of_a_transformer_bushing\" class=\"ez-toc-section\"><\/span><strong>Wie hoch ist die Lebensdauer einer Transformator-Durchf\u00fchrung?<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h5>\n<p class=\"saswp-faq-answer-text\">Transformator-Durchf\u00fchrungen sind so konzipiert, dass sie w\u00e4hrend der gesamten Lebensdauer des Transformators, an dem sie installiert sind, eine effiziente Leistung erbringen. F\u00fcr jede Transformator-Durchf\u00fchrung betr\u00e4gt die normale Lebensdauer 10 bis 25 Jahre. <a href=\"https:\/\/www.daelimtransformer.com\/de\/transformer-lifespan.html\">Nutzungsdauer<\/a> in der es die beste Leistung erbringt.<\/p>\n<\/li>\n<\/ol>\n<\/div>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Conclusion\"><\/span>Fazit<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"2508\" height=\"1412\" src=\"https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/04\/daelim-transformer-manufacturer.webp\" alt=\"daelim-transformer-manufacturer\" class=\"wp-image-12466\" srcset=\"https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/04\/daelim-transformer-manufacturer.webp 2508w, https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/04\/daelim-transformer-manufacturer-768x432.webp 768w, https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/04\/daelim-transformer-manufacturer-1536x865.webp 1536w, https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/04\/daelim-transformer-manufacturer-2048x1153.webp 2048w, https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/04\/daelim-transformer-manufacturer-600x338.webp 600w\" sizes=\"(max-width: 2508px) 100vw, 2508px\" \/><figcaption class=\"wp-element-caption\">daelim-transformer-manufacturer<\/figcaption><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Transformator-Durchf\u00fchrungen sorgen f\u00fcr eine sichere und zuverl\u00e4ssige Verbindung zwischen den inneren und \u00e4u\u00dferen Teilen eines Transformators. Die Auswahl der richtigen Art, Gr\u00f6\u00dfe und des richtigen Materials f\u00fcr Transformator-Durchf\u00fchrungen ist entscheidend f\u00fcr die Effizienz und die Einhaltung internationaler Normen. Bei Daelim Belefic sorgen unsere Ingenieure mit jahrzehntelanger Erfahrung daf\u00fcr, dass jeder Transformator mit dem richtigen Durchf\u00fchrungstyp konstruiert und gebaut wird. Wenn Sie Hilfe ben\u00f6tigen oder Fragen zur Konstruktion, Dimensionierung und Lieferung von Transformator-Durchf\u00fchrungen haben, <a href=\"https:\/\/www.daelimtransformer.com\/de\/contact-us\/\">Kontaktieren Sie uns<\/a> jetzt!<\/p>","protected":false},"excerpt":{"rendered":"<p>Electrical Transformers are an amazing piece of equipment that work to regulate megawatts of electrical power using components present inside its tank. Transformer bushing is used to safely connect these internal components with external electrical circuits. In this article we will discuss Transformer bushing in a very comprehensive manner. We will study what bushing is, [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":13677,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[279],"tags":[],"class_list":["post-13655","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articles-news"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/posts\/13655","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/comments?post=13655"}],"version-history":[{"count":8,"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/posts\/13655\/revisions"}],"predecessor-version":[{"id":13695,"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/posts\/13655\/revisions\/13695"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/media\/13677"}],"wp:attachment":[{"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/media?parent=13655"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/categories?post=13655"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/tags?post=13655"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}