{"id":7014,"date":"2026-01-05T03:49:09","date_gmt":"2026-01-05T03:49:09","guid":{"rendered":"https:\/\/daelimtransformer.com\/?p=7014"},"modified":"2026-03-08T08:22:27","modified_gmt":"2026-03-08T08:22:27","slug":"what-is-a-substation-transformer","status":"publish","type":"post","link":"https:\/\/www.daelimtransformer.com\/de\/a-substation-transformer.html","title":{"rendered":"Was ist ein Umspanntransformator?"},"content":{"rendered":"<div id=\"contentMain\" class=\"article-content\">\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><img decoding=\"async\" src=\"\/media\/115\/2000kva%2033kv%20substation%20transformer.jpg\" \/><\/p>\n<h2><span class=\"ez-toc-section\" id=\"1What_is_substation_transformer\"><\/span>1.Was ist ein Umspanntransformator?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><a href=\"https:\/\/www.daelimtransformer.com\/de\/1500-kva-substation-transformer.html\"><img decoding=\"async\" style=\"float: right; width: 340px; height: 340px;\" src=\"\/media\/115\/1500-kva-substation-transformer.webp\" \/><\/a><a href=\"https:\/\/www.daelimtransformer.com\/de\/substation-transformer.html\">Umspannertransformatoren<\/a> sind f\u00fcr die Installation in gro\u00dfen oder kleinen dreiphasigen \u00dcbertragungs- und Verteilungssystemen konzipiert. Der Installationsort ist \u00fcblich und muss auf dem Innen- oder Au\u00dfenbetonfundament liegen, das in der fr\u00fchen Phase der Projektplanung von dem Elektroingenieur entworfen werden muss.<\/p>\n<p>Gleichzeitig werden die Kabel auf der Hochspannungs- oder Niederspannungsseite des Umspanntransformators durch die Durchf\u00fchrungen am Halsseiteneingang oder der Durchf\u00fchrungen oben angeschlossen, um den Strom direkt in den Betriebsraum anderer Umstationstechnik zu leiten, wie zum Beispiel den Schaltschrank und andere Ger\u00e4te.<\/p>\n<p>Zus\u00e4tzlich sind Umspanntransformatoren in der Regel \u00f6lgetaucht. Mineral\u00f6l, Pflanzen\u00f6l oder kiesels\u00e4urehaltiges Transformator\u00f6l. Weit verbreitet in verschiedenen Versorgungs- oder kleinen industriellen Anwendungen. Die Konstruktionsstandards basieren in der Regel auf IEC, IEEE oder anderen internationalen Standards. Lassen Sie uns \u00fcber die Spannungsstufen von Transformatoren in Umspannwerken sprechen. Die Prim\u00e4rspannung von Transformatoren in Umspannwerken betr\u00e4gt normalerweise mindestens 2,4 kV und maximal 69 kV, was auf dem IEEE-Standard basiert. Die Mindestleistung betr\u00e4gt 150 kVA bis maximal <a href=\"https:\/\/www.daelimtransformer.com\/de\/20-mva-substation-transformer.html\">20MVA<\/a>, und die Sekund\u00e4rspannung kann ebenfalls eine Mindestspannung von 0,6 kV und einen maximalen Spannungswert von 35 kV aufweisen.<\/p>\n<p>Gleichzeitig k\u00f6nnen Umspanntransformatoren hinsichtlich der Nutzungsszenarien in \u00f6ffentliche Umspanntransformatoren und pers\u00f6nliche industrielle Umspanntransformatoren unterteilt werden:<\/p>\n<h3><span class=\"ez-toc-section\" id=\"_Utility_substation_transformers\"><\/span>* Netzumspanntransformatoren:<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 10.5pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 10.5000pt;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"font-family: Calibri;\">In diesem Fall wird es von Industrieunternehmen zur Stromverteilung genutzt, und die Ausgangsspannung wird schlie\u00dflich von privaten Endverbrauchern verwendet. Es wird sowohl einphasiger als auch dreiphasiger Wechselstrom bereitgestellt. Einige g\u00e4ngige Werte sind 120 V, 240 V, 400 V usw. Verwendung in st\u00e4dtischen oder l\u00e4ndlichen Stromverteilungssystemen. Dann wird in mehrere oder einzelne kleine Leistungstransformatoren f\u00fcr Niederspannung eingespeist. Die Transformatoren von st\u00e4dtischen Umspannwerken werden normalerweise mit Ziegeln gebaut, um eine Schutzmauer zu bilden, w\u00e4hrend die Transformatoren von l\u00e4ndlichen Umspannwerken in der Regel an Freileitungen und T\u00fcrmen auftreten.<\/span><\/span><\/span><\/span><\/span><\/p>\n<p><strong>Sie k\u00f6nnten genie\u00dfen:\u00a0<a href=\"https:\/\/www.daelimtransformer.com\/de\/utility-transformer.html\">Ultimative Anleitung zum Transformator f\u00fcr Versorgungsunternehmen<\/a><\/strong><\/p>\n<h3><span class=\"ez-toc-section\" id=\"Personal_substation_transformers\"><\/span>* Pers\u00f6nliche Umspanntransformatoren<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Wir verstehen, dass der Umspanntransformator, der vom Endbenutzer verwendet wird, f\u00fcr den pers\u00f6nlichen Gebrauch des Endbenutzers gedacht ist. In der Regel wird er von Netzen mit Mittel- und Niederspannungspegeln gespeist und in Schulen, Krankenh\u00e4usern, Restaurants usw. eingesetzt.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Underground_substation_transformer\"><\/span>* Unterirdischer Umspanntransformator<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Manchmal wird aufgrund von Platzbeschr\u00e4nkungen ein unterirdischer Umspanntransformator speziell entworfen, um den Umweltanforderungen gerecht zu werden. Es sind nur die speziellen Anforderungen des Untergrunds, auf die wir achten m\u00fcssen:<\/p>\n<p>F\u00fcr Installationen mit eingeschr\u00e4nktem Platz m\u00fcssen spezielle Medien und spezielle \u00d6le hinsichtlich der Sicherheit ber\u00fccksichtigt werden, und in Bezug auf die Qualit\u00e4t muss die h\u00f6chste Qualit\u00e4t ber\u00fccksichtigt werden, um die Betriebsrisiken und wirtschaftlichen Vorteile des Maschinenbetriebs zu minimieren.<\/p>\n<p><strong>Sie k\u00f6nnten genie\u00dfen:\u00a0<a href=\"https:\/\/www.daelimtransformer.com\/de\/pad-mounted-transformer.html\">Bodenmontierter Transformator<\/a><\/strong><\/p>\n<h2><span class=\"ez-toc-section\" id=\"2How_does_a_substation_transformer_work\"><\/span>2.Wie funktioniert ein Umspanntransformator?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 10.5pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 10.5000pt;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"font-family: Calibri;\">Die Hauptstromquelle des Transformators im Umspannwerk basiert auf dem Eingangsstrom des Verteilungsnetzes. Ein einfaches Verst\u00e4ndnis des Prinzips ist, dass das Transformatoren\u00f6l im Umspannwerk aus zwei benachbarten Wicklungswicklungen besteht. Ein magnetisches Feld entsteht, wenn eine Spannung \u00fcber eine der Wicklungswicklungen fluktuiert. Das hier entstehende magnetische Feld koppelt an die unmittelbar benachbarte Wicklung, erh\u00e4lt eine Spannung und reagiert darauf. <\/span><\/span><\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 10.5pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 10.5000pt;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"font-family: Calibri;\">Das Verh\u00e4ltnis der induzierten Spannung des Umspannwerktransformators zur Schlaufe der Wicklung wird zum vorw\u00e4rtsproportionalen Kriterium. Zum Beispiel, wenn 10.000 Wicklungen \u00fcbertragen werden, werden 1.000 Wicklungen im Verteilungstest erzeugt, und die Spannung, die durch den Verteilungstest erzeugt wird, wird um das Zehnfache reduziert. Dieses Prinzip ist gut verst\u00e4ndlich, sodass wir je nach Bedarf an elektrischer Energie Druck aufbauen oder abbauen k\u00f6nnen, um sicherzustellen, dass die Leistungsf\u00e4higkeit jedes Teils des Stromnetzes gut erf\u00fcllt wird und die Sicherheit sowie Wirtschaftlichkeit jedes Stromkreises gew\u00e4hrleistet sind.<\/span><\/span><\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><img decoding=\"async\" src=\"\/media\/115\/Oil%20immersed%20distribution%20transformer.jpg\" \/><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 10.5pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 10.5000pt;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"font-family: Calibri;\">Gleichzeitig umfassen Umspannwerktransformatoren auch Ger\u00e4te, die das gesamte \u00dcbertragungs- und Verteilungsnetz steuern. Zum Beispiel ist der Leistungsschaltertransformator ein kleiner Transformator, der haupts\u00e4chlich zur \u00dcberwachung der Sicherheitsleistung und zur Erfassung des Stroms und der Leistung verwendet wird. Auf diese Weise kann der sichere Betrieb der gesamten Umspannwerkausr\u00fcstung erreicht werden, wodurch die Umspannwerktransformatoren erg\u00e4nzt werden. Abh\u00e4ngig von den \u00dcbertragungs- und Verteilungsverlusten kann die Spannung im Netz au\u00dferhalb des akzeptablen Bereichs schwanken.<\/span><\/span><\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 10.5pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 10.5000pt;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"font-family: Calibri;\">Tats\u00e4chlich ist das Stromsystem und sogar der Umspannwerktransformator aus vielen Perspektiven und Aspekten ein gro\u00dfes Ger\u00e4tesystem, das mit dem Leben eines jeden von uns verbunden sein kann. Ob es sich um grundlegende Ger\u00e4te oder den t\u00e4glichen Stromverbrauch handelt, Strom wird ben\u00f6tigt, insbesondere zuverl\u00e4ssiger und sicherer Strom. Obwohl die Gr\u00f6\u00dfe des Einsatzortes und die Spannungsebene des verwendeten Stroms variieren.<\/span><\/span><\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 10.5pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 10.5000pt;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"font-family: Calibri;\">Jeder Umspannwerktransformator ist einzigartig und ma\u00dfgeschneidert. Mit der Intelligenzsteigerung von Stromger\u00e4ten und der rasanten Entwicklung verschiedener nachhaltiger und umweltfreundlicher Energieerzeugung wird davon ausgegangen, dass Umspannwerktransformatoren in unserem zuk\u00fcnftigen Leben mehr Herausforderungen mit sich bringen werden. Und die M\u00f6glichkeit, mehr Sicherheit und Zuverl\u00e4ssigkeit zu entwickeln.<\/span><\/span><\/span><\/span><\/span><\/p>\n<h2><span class=\"ez-toc-section\" id=\"3What_types_of_substation_transformer_are_there\"><\/span>3.Welche Arten von Umspanntransformatoren gibt es?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<\/div>\n<div><a href=\"https:\/\/www.daelimtransformer.com\/de\/69kv-transformer.html\"><img decoding=\"async\" class=\"alignright\" style=\"width: 264px; height: 279px; float: right;\" src=\"\/media\/115\/canada-69-kv-transformer.webp\" \/><\/a><\/div>\n<div class=\"article-content\">\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 10.5pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 10.5000pt;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"font-weight: normal;\"><span style=\"font-family: Calibri;\">Wir k\u00f6nnen es in viele Ebenen unterteilen, um die verschiedenen Arten von Umspannwerktransformatoren zu verstehen:<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 10.5pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 10.5000pt;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"font-weight: normal;\"><span style=\"font-family: Calibri;\">* Unterscheidung nach Spannungsniveau:<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 10.5pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 10.5000pt;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"font-weight: normal;\"><span style=\"font-family: Calibri;\">Hochspannungs-Umspannwerktransformator<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 10.5pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 10.5000pt;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"font-weight: normal;\"><span style=\"font-family: Calibri;\">Der Spannungsbereich betr\u00e4gt mindestens <a href=\"https:\/\/www.daelimtransformer.com\/de\/69kv-power-transformer.html\" target=\"_blank\" rel=\"noopener\">11 kV bis maximal 69 kV.<\/a><\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 10.5pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 10.5000pt;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"font-weight: normal;\"><span style=\"font-family: Calibri;\">EHV-Umspannwerk<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 10.5pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 10.5000pt;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"font-weight: normal;\"><span style=\"font-family: Calibri;\">Spannungsbereiche von mindestens <a href=\"https:\/\/www.daelimtransformer.com\/de\/138kv-power-transformer.html\" target=\"_blank\" rel=\"noopener\">132 kV bis maximal 440 kV.<\/a><\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 10.5pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 10.5000pt;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"font-weight: normal;\"><span style=\"font-family: Calibri;\">Es gibt einen Hochspannungstransformator, der von Niederspannung auf Hochspannung hochtransformiert und einen Schritt-Down-Transformator von Hochspannung auf Niederspannung.<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 10.5pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 10.5000pt;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"font-weight: normal;\"><span style=\"font-family: Calibri;\">* Gleichzeitig gibt es einen Umspannwerktransformator, der die Spannung nicht \u00e4ndert, was sich auf einen Umspannwerktransformator bezieht, der Strom in kurzer Zeit isoliert und eine Rolle bei Isolation und Sicherheit im Falle eines Stromausfalls spielt.<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 10.5pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 10.5000pt;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"font-weight: normal;\"><span style=\"font-family: Calibri;\">* Es gibt auch einen Umspannwerktransformator, der die Frequenz \u00e4ndert.<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 10.5pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 10.5000pt;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"font-weight: normal;\"><span style=\"font-family: Calibri;\">Da er die Frequenz \u00e4ndert, wird er als variabler Frequenzumspannwerktransformator bezeichnet, der von einzelnen Haushalten weniger genutzt wird und haupts\u00e4chlich in industriellen Umspannwerken Verwendung findet.<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 10.5pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 10.5000pt;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"font-weight: normal;\"><span style=\"font-family: Calibri;\">Direkter gibt es einen Umspannwerktransformator, der die <a href=\"https:\/\/en.wikipedia.org\/wiki\/Power_supply\" target=\"_blank\" rel=\"noopener\">AC\/DC-Stromversorgung \u00e4ndert.<\/a>. Haupts\u00e4chlich verwendet in der Elektroplattierung.<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 10.5pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 10.5000pt;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"font-weight: normal;\"><span style=\"font-family: Calibri;\">*Es gibt auch einen Unterschied basierend auf dem Verteilungsort des Stromnetzes: Es gibt zwei Haupttypen.<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 10.5pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 10.5000pt;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"font-weight: normal;\"><span style=\"font-family: Calibri;\">Netztyp-Umspannwerke, die haupts\u00e4chlich zur \u00dcbertragung von Hochspannungsstrom mit gro\u00dfer Kapazit\u00e4t verwendet werden, k\u00f6nnen nur in Au\u00dfengeb\u00e4uden eingesetzt werden und sind.<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 10.5pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 10.5000pt;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"font-weight: normal;\"><span style=\"font-family: Calibri;\">Der andere ist h\u00e4ufiger in unserer Lebensumgebung anzutreffen, das sind st\u00e4dtische und l\u00e4ndliche Transformatoren der Umspannwerke. Die Hauptanwendung besteht darin, bei Nieder- und Mittelspannungen von 10KV bis 33KV zu arbeiten.<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 10.5pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 10.5000pt;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"font-weight: normal;\"><span style=\"font-family: Calibri;\">Das oben Genannte ist, wie man verschiedene Transformatoren der Umspannwerke unterscheiden kann. Wir k\u00f6nnen es aus verschiedenen Perspektiven und Kontexten verstehen.<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<h2><span class=\"ez-toc-section\" id=\"4How_much_does_a_substation_transformer_weight\"><\/span>4.Wie viel wiegt ein Umspanntransformator?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<table align=\"center\">\n<tbody>\n<tr>\n<td rowspan=\"2\" valign=\"center\" width=\"7.0000%\">\n<p align=\"center\">(KVA)<\/p>\n<p align=\"center\">Nenn<\/p>\n<p align=\"center\">Leistung<\/p>\n<\/td>\n<td rowspan=\"2\" valign=\"center\" width=\"8.0600%\">\n<p align=\"center\">(KV)<\/p>\n<p align=\"center\">Hoch<\/p>\n<p align=\"center\">Spannung<\/p>\n<\/td>\n<td rowspan=\"2\" valign=\"center\" width=\"8.2800%\">\n<p align=\"center\">(V)<\/p>\n<p align=\"center\">Niedrig<\/p>\n<p align=\"center\">Spannung<\/p>\n<\/td>\n<td rowspan=\"2\" valign=\"center\" width=\"12.2200%\">\n<p align=\"center\">Verbindung<\/p>\n<p align=\"center\">Symbol<\/p>\n<\/td>\n<td rowspan=\"2\" valign=\"center\" width=\"13.0400%\">\n<p align=\"center\">(%)<\/p>\n<p align=\"center\">Kurz<\/p>\n<p align=\"center\">Stromkreis<\/p>\n<p align=\"center\">Impedanz<\/p>\n<\/td>\n<td colspan=\"2\" valign=\"center\" width=\"17.3800%\">\n<p align=\"center\">(W)<\/p>\n<p align=\"center\">Verlust<\/p>\n<\/td>\n<td rowspan=\"2\" valign=\"center\" width=\"17.5400%\">\n<p align=\"center\">Referenz<\/p>\n<p align=\"center\">Dimension<\/p>\n<p align=\"center\">(B*H*T)<\/p>\n<p align=\"center\">mm<\/p>\n<\/td>\n<td rowspan=\"2\" valign=\"center\" width=\"16.4000%\">\n<p align=\"center\">Referenz<\/p>\n<p align=\"center\">Gewicht<\/p>\n<p align=\"center\">kg<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"8.5400%\">\n<p align=\"center\">(W)<\/p>\n<p align=\"center\">Leerlaufverlust<\/p>\n<\/td>\n<td valign=\"center\" width=\"8.8200%\">\n<p align=\"center\">\u00a0(W)<\/p>\n<p align=\"center\">Lastverlust<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"7.0000%\">\n<p align=\"center\">800<\/p>\n<\/td>\n<td rowspan=\"10\" valign=\"center\" width=\"8.0600%\">\n<p align=\"center\">4.16<\/p>\n<p align=\"center\">12.00<\/p>\n<p align=\"center\">12.47<\/p>\n<p align=\"center\">13.2<\/p>\n<p align=\"center\">13.8<\/p>\n<p align=\"center\">14.4<\/p>\n<p align=\"center\">23.0<\/p>\n<p align=\"center\">24.94<\/p>\n<p align=\"center\">34.5<\/p>\n<p align=\"center\">34.8\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a044 \u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0oder andere<\/p>\n<\/td>\n<td rowspan=\"10\" valign=\"center\" width=\"8.2800%\">\n<p align=\"justify\">208\/120<\/p>\n<p align=\"center\">415\/240<\/p>\n<p align=\"center\">480\/277<\/p>\n<p align=\"center\">400<\/p>\n<p align=\"center\">600<\/p>\n<p align=\"center\">12000<\/p>\n<p align=\"center\">12470<\/p>\n<p align=\"center\">13200<\/p>\n<p align=\"center\">13800<\/p>\n<p align=\"center\">oder andere<\/p>\n<\/td>\n<td rowspan=\"10\" valign=\"center\" width=\"12.2200%\">\n<p align=\"center\">Dyn1<\/p>\n<p align=\"center\">Ynyn0<\/p>\n<p align=\"center\">Dyn11<\/p>\n<p align=\"center\">Dd0<\/p>\n<p align=\"center\">Ynd11<\/p>\n<p align=\"center\">oder<\/p>\n<p align=\"center\">andere<\/p>\n<\/td>\n<td rowspan=\"10\" valign=\"center\" width=\"13.0400%\">\n<p align=\"center\">2.7<\/p>\n<p align=\"center\">3.1<\/p>\n<p align=\"center\">4.35<\/p>\n<p align=\"center\">5.75<\/p>\n<p align=\"center\">6.0<\/p>\n<\/td>\n<td valign=\"center\" width=\"8.5400%\">\n<p align=\"center\">980<\/p>\n<\/td>\n<td valign=\"center\" width=\"8.8200%\">\n<p align=\"center\">9350<\/p>\n<\/td>\n<td valign=\"center\" width=\"17.5400%\">\n<p align=\"center\">1060*1500*1780<\/p>\n<\/td>\n<td valign=\"center\" width=\"16.4000%\">\n<p align=\"center\">2050<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"7.0000%\">\n<p align=\"center\">1000<\/p>\n<\/td>\n<td valign=\"center\" width=\"8.5400%\">\n<p align=\"center\">1160<\/p>\n<\/td>\n<td valign=\"center\" width=\"8.8200%\">\n<p align=\"center\">11500<\/p>\n<\/td>\n<td valign=\"center\" width=\"17.5400%\">\n<p align=\"center\">1085*1570*1800<\/p>\n<\/td>\n<td valign=\"center\" width=\"16.4000%\">\n<p align=\"center\">2450<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"7.0000%\">\n<p align=\"center\">1250<\/p>\n<\/td>\n<td valign=\"center\" width=\"8.5400%\">\n<p align=\"center\">1380<\/p>\n<\/td>\n<td valign=\"center\" width=\"8.8200%\">\n<p align=\"center\">13900<\/p>\n<\/td>\n<td valign=\"center\" width=\"17.5400%\">\n<p align=\"center\">1160*1610*1890<\/p>\n<\/td>\n<td valign=\"center\" width=\"16.4000%\">\n<p align=\"center\">2900<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"7.0000%\">\n<p align=\"center\">1600<\/p>\n<\/td>\n<td valign=\"center\" width=\"8.5400%\">\n<p align=\"center\">1660<\/p>\n<\/td>\n<td valign=\"center\" width=\"8.8200%\">\n<p align=\"center\">16600<\/p>\n<\/td>\n<td valign=\"center\" width=\"17.5400%\">\n<p align=\"center\">1190*1630*1950<\/p>\n<\/td>\n<td valign=\"center\" width=\"16.4000%\">\n<p align=\"center\">3400<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"7.0000%\">\n<p align=\"center\">2000<\/p>\n<\/td>\n<td valign=\"center\" width=\"8.5400%\">\n<p align=\"center\">2030<\/p>\n<\/td>\n<td valign=\"center\" width=\"8.8200%\">\n<p align=\"center\">18300<\/p>\n<\/td>\n<td valign=\"center\" width=\"17.5400%\">\n<p align=\"center\">1260*1700*2090<\/p>\n<\/td>\n<td valign=\"center\" width=\"16.4000%\">\n<p align=\"center\">4100<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"7.0000%\">\n<p align=\"center\">2500<\/p>\n<\/td>\n<td valign=\"center\" width=\"8.5400%\">\n<p align=\"center\">2450<\/p>\n<\/td>\n<td valign=\"center\" width=\"8.8200%\">\n<p align=\"center\">19600<\/p>\n<\/td>\n<td valign=\"center\" width=\"17.5400%\">\n<p align=\"center\">1150*2150*2250<\/p>\n<\/td>\n<td valign=\"center\" width=\"16.4000%\">\n<p align=\"center\">4750<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"7.0000%\">\n<p align=\"center\">3000<\/p>\n<\/td>\n<td valign=\"center\" width=\"8.5400%\">\n<p align=\"center\">3240<\/p>\n<\/td>\n<td valign=\"center\" width=\"8.8200%\">\n<p align=\"center\">26500<\/p>\n<\/td>\n<td valign=\"center\" width=\"17.5400%\">\n<p align=\"center\">1900*2600*2150<\/p>\n<\/td>\n<td valign=\"center\" width=\"16.4000%\">\n<p align=\"center\">6500<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"7.0000%\">\n<p align=\"center\">5000<\/p>\n<\/td>\n<td valign=\"center\" width=\"8.5400%\">\n<p align=\"center\">4500<\/p>\n<\/td>\n<td valign=\"center\" width=\"8.8200%\">\n<p align=\"center\">27000<\/p>\n<\/td>\n<td valign=\"center\" width=\"17.5400%\">\n<p align=\"center\">2500*2210*3180<\/p>\n<\/td>\n<td valign=\"center\" width=\"16.4000%\">\n<p align=\"center\">9500<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"7.0000%\">\n<p align=\"center\">7500<\/p>\n<\/td>\n<td valign=\"center\" width=\"8.5400%\">\n<p align=\"center\">7200<\/p>\n<\/td>\n<td valign=\"center\" width=\"8.8200%\">\n<p align=\"center\">32000<\/p>\n<\/td>\n<td valign=\"center\" width=\"17.5400%\">\n<p align=\"center\">3660*3100*5100<\/p>\n<\/td>\n<td valign=\"center\" width=\"16.4000%\">\n<p align=\"center\">13600<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"7.0000%\">\n<p align=\"center\">10000<\/p>\n<\/td>\n<td valign=\"center\" width=\"8.5400%\">\n<p align=\"center\">8500<\/p>\n<\/td>\n<td valign=\"center\" width=\"8.8200%\">\n<p align=\"center\">35500<\/p>\n<\/td>\n<td valign=\"center\" width=\"17.5400%\">\n<p align=\"center\">3830*2640*2216<\/p>\n<\/td>\n<td valign=\"center\" width=\"16.4000%\">\n<p align=\"center\">15800<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>* Dimension, Gewicht und Verlust sind zur Referenz. Wird basierend auf dem tats\u00e4chlichen Projekt, Design und Standard sein.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"5Substation_transformer_testing\"><\/span>5.\u00dcberpr\u00fcfung von Umspanntransformatoren?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><img decoding=\"async\" class=\"alignright\" style=\"width: 339px; height: 314px; float: right;\" src=\"\/media\/115\/power-transformer-routine-tests.webp\" \/><span style=\"font-size: 10.5pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 10.5000pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-weight: normal;\">Die Transformatorpr\u00fcfung hat sich \u00fcber einen langen Zeitraum entwickelt und entwickelt sich seit der Entstehung des Transformators weiter. Vom Anfang der einfachen Testdaten, die nicht zufriedenstellend sind, bis hin zu den Testdaten, die die komplexen Daten und Strukturen des Transformators von au\u00dfen nach innen zeigen k\u00f6nnen, was zweifellos beweist, dass der Transformator eine sichere und zuverl\u00e4ssige professionelle Rolle in der gesamten Stromentwicklung gespielt hat. Jetzt k\u00f6nnen wir \u00fcber die gleichen und unterschiedlichen Testinhalte unter den am h\u00e4ufigsten verwendeten IEC- und IEEE-Standards diskutieren.<\/span><\/span><\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 10.5pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 10.5000pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-weight: normal;\">\u00a0Es gibt Testinhalte unter dem IEC-Standard:<\/span><\/span><\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 10.5pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 10.5000pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-weight: normal;\">\u2013 Dielektrischer Test<\/span><\/span><\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 10.5pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 10.5000pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-weight: normal;\">\u2013 Impulstest<\/span><\/span><\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 10.5pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 10.5000pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-weight: normal;\">\u2013 Blitzimpulstest<\/span><\/span><\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 10.5pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 10.5000pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-weight: normal;\">\u2013 Drucktest<\/span><\/span><\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 10.5pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 10.5000pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-weight: normal;\">\u2013 Teilentladungsmessung, Vollentladungspr\u00fcfung, Harmonische Entladungspr\u00fcfung<\/span><\/span><\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 10.5pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 10.5000pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-weight: normal;\">\u2013 Erzeugter AC-Spannungstest,<\/span><\/span><\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 10.5pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 10.5000pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-weight: normal;\">- Verlusttest im Leerlauf, Verlusttest unter Last<\/span><\/span><\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 10.5pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 10.5000pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-weight: normal;\">- Temperaturanstiegstest<\/span><\/span><\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 10.5pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 10.5000pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-weight: normal;\">Diese Tests k\u00f6nnen verpflichtend oder nicht verpflichtend sein, k\u00f6nnen jedoch gem\u00e4\u00df den tats\u00e4chlichen Versuchsbedingungen des Herstellers und den Kundenbed\u00fcrfnissen verhandelt werden.<\/span><\/span><\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"color: #27ae60;\"><strong><span style=\"font-size: 18px;\"><span style=\"font-family: Calibri;\">Mehr lesen \u00fcber <\/span><\/span><\/strong><\/span><strong><span style=\"font-size: 18px;\"><span style=\"font-family: Calibri;\"><a href=\"https:\/\/www.daelimtransformer.com\/de\/test-of-power-transformer.html\"><span style=\"color: #c0392b;\">Transformator-Test<\/span><\/a><\/span><\/span><\/strong><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><img decoding=\"async\" src=\"\/media\/115\/furnace%20transformer%20drawings.jpg\" \/><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 10.5pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 10.5000pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-weight: normal;\">Testinhalte unter IEEE-Standards<\/span><\/span><\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 10.5pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 10.5000pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-weight: normal;\">Wir sollten zun\u00e4chst den Widerstandstest, Polarity-Test, Phasenbeziehungstest, Ratio-Test, Verlusttest im Leerlauf, Verlusttest unter Last und Eignungstemperaturanstiegstest, dielektrischen Test in Betracht ziehen. Gleichzeitig, um die Sicherheit des Tests und die Sch\u00e4den am Transformator zu gew\u00e4hrleisten, sollte der Spannungsteil, der mit dem Strom verbunden ist, zuerst getestet werden.<\/span><\/span><\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 10.5pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 10.5000pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-weight: normal;\">Dar\u00fcber hinaus ist der Blitztest kein Pflichttest, insbesondere unter der Bedingung kleiner Kapazit\u00e4t und Spannung kann ein Blitztest katastrophale Verluste f\u00fcr den Transformator verursachen, wir k\u00f6nnen den Stichproben-Test unter diesen Bedingungen in Betracht ziehen.<\/span><\/span><\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 10.5pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 10.5000pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-weight: normal;\">Gleichzeitig gibt es Niedrigfrequenztests, induzierte Spannungstests usw.<\/span><\/span><\/span><\/span><\/span><\/p>\n<h2><span class=\"ez-toc-section\" id=\"Substation_Transformer_Manufacturer\"><\/span>Hersteller von Umspanntransformatoren<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><a href=\"https:\/\/www.daelimtransformer.com\/de\/substation-transformer.html\"><img decoding=\"async\" src=\"\/media\/115\/daelim-substation-transformer-skid-mounted-transformer.webp\" \/><\/a><\/p>\n<p><span style=\"font-size: 10.5pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 10.5000pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-weight: normal;\">Daelim Transformer ist Ihre erste Wahl f\u00fcr hochwertige Umspannungsstationstransformatoren. Als f\u00fchrender Hersteller und Lieferant bieten wir Transformatoren an, die den neuesten internationalen Standards entsprechen, einschlie\u00dflich IEEE, ANSI, CSA, IEC und AS. Unsere Produkte sind zertifiziert von <span style=\"font-size: 16px;\"><strong><a href=\"https:\/\/www.daelimtransformer.com\/de\/certificate.html\"><span style=\"color: #c0392b;\">UL, cUL, CSA, CE<\/span><\/a><\/strong><\/span>, und FM, was unvergleichliche Zuverl\u00e4ssigkeit und Leistung gew\u00e4hrleistet.<\/span><\/span><\/span><\/span><\/span><\/p>\n<p><span style=\"font-size: 10.5pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 10.5000pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-weight: normal;\">Daelim Transformer verf\u00fcgt \u00fcber umfangreiche Erfahrungen bei Projekten mit Umspannungsstationstransformatoren in Nordamerika, Lateinamerika und Australien. Wir bieten ma\u00dfgeschneiderte L\u00f6sungen, die auf Ihre spezifischen technischen Anforderungen zugeschnitten sind. Unser Fachwissen reicht \u00fcber die Fertigung hinaus und umfasst eine umfassende Palette von Dienstleistungen, wie fachgerechte Installation, laufende Wartung und reaktionsschnelle Unterst\u00fctzung vor Ort, die alle darauf ausgelegt sind, dass Ihre Abl\u00e4ufe reibungslos laufen.<\/span><\/span><\/span><\/span><\/span><\/p>\n<p><span style=\"font-size: 10.5pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 10.5000pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-weight: normal;\">Mit Servicestationen in den Vereinigten Staaten, Kanada, Spanien und anderen L\u00e4ndern verpflichtet sich Daelim Transformer, die besten Transformatorenl\u00f6sungen weltweit anzubieten. W\u00e4hlen Sie Daelim Transformer f\u00fcr Ihr n\u00e4chstes Projekt und erleben Sie den Unterschied, den Effizienz und Fachwissen ausmachen k\u00f6nnen.<\/span><\/span><\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><a href=\"https:\/\/www.daelimtransformer.com\/de\/contact.html\" target=\"_blank\" rel=\"noopener\"><u><em><strong><span style=\"font-size: 10.5pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 10.5000pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-weight: normal;\">Anfragen sind willkommen, klicken Sie hier, um mehr zu erfahren!<\/span><\/span><\/span><\/span><\/span><\/strong><\/em><\/u><\/a><\/p>\n<p><!-- \u5de6\u53f3\u56fe\u6587--><\/p>\n<p><!-- \u8c46\u8150\u5757\u56fe\u6587\u4e0a\u4e0b--><\/p>\n<p><!--\u6587\u5b57\u6a21\u5757--><\/p>\n<p><!-- \u5de6\u53f3\u56fe\u6587--><\/p>\n<p><!--\u6587\u5b57\u6a21\u5757--><\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>1.What is substation transformer? Substation transformers are designed for installation in large or small three-phase transmission and distribution power systems. The installation location is common and must be on the indoor or outdoor concrete base, which needs to be designed by the power engineer in the early stage of project planning. At the same time, [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":7015,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[277],"tags":[],"class_list":["post-7014","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/posts\/7014","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/comments?post=7014"}],"version-history":[{"count":0,"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/posts\/7014\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/media\/7015"}],"wp:attachment":[{"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/media?parent=7014"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/categories?post=7014"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/tags?post=7014"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}