{"id":7234,"date":"2026-01-05T08:03:23","date_gmt":"2026-01-05T08:03:23","guid":{"rendered":"https:\/\/daelimtransformer.com\/?p=7234"},"modified":"2026-03-23T11:26:45","modified_gmt":"2026-03-23T11:26:45","slug":"basic-guide-for-grounding-transformer","status":"publish","type":"post","link":"https:\/\/www.daelimtransformer.com\/de\/grounding-transformer.html","title":{"rendered":"Grundlegender Leitfaden zur Erdung des Transformators"},"content":{"rendered":"<div id=\"contentMain\" class=\"article-content\">\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 18px;\"><span style=\"font-family: Calibri;\"><span style=\"font-family: Calibri;\">Im dreiphasigen Stromsystem spielt der Erdungstransformator die Rolle und Funktion eines Hilfstransformators. Die Funktion eines Erdungstransformators besteht darin, den Erdungsmodus f\u00fcr ungenutzte Delta- oder Sternverbindungen bereitzustellen. Daher ist ein Erdungstransformator auch ein sehr wichtiger Teil des Erdungssystems des Stromnetzes.<\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 18px;\"><span style=\"font-family: Calibri;\"><span style=\"font-family: Calibri;\"><a href=\"https:\/\/www.daelimtransformer.com\/de\/\" target=\"_blank\" rel=\"noopener\">Daelim Transformer<\/a>\u00a0ist ein Transformatorenhersteller mit mehr als 20 Jahren Erfahrung in der Transformatorproduktion und im Export. Die Hauptprodukte von Daelim umfassen <a href=\"https:\/\/www.daelimtransformer.com\/de\/pad-mounted-transformer.html\">Pad-Montierter Transformator<\/a>, <a href=\"https:\/\/www.daelimtransformer.com\/de\/single-phase-pad-mounted-transformer.html\" target=\"_blank\" rel=\"noopener\">Einphasen-Mastenmontierter Transformator<\/a>, <a href=\"https:\/\/www.daelimtransformer.com\/de\/substation-transformer.html\" target=\"_blank\" rel=\"noopener\">Umspannungstransformator<\/a> und der <a href=\"https:\/\/www.daelimtransformer.com\/de\/power-transformer.html\" target=\"_blank\" rel=\"noopener\">Leistungstransformator.<\/a> Die von DAELIM produzierten und verkauften Transformatoren unterliegen strengen Inspektionen und Tests, um die hohe Qualit\u00e4t der Transformatoren sicherzustellen. <a href=\"https:\/\/www.daelimtransformer.com\/de\/contact.html\" target=\"_blank\" rel=\"noopener\">Willkommen, Kunden, die Transformatoren kaufen m\u00f6chten, um Rat zu suchen.<\/a><\/span><\/span><\/span><\/p>\n<h2 style=\"margin-top: 0.0000pt; margin-bottom: 0.0000pt; text-align: justify;\"><\/h2>\n<h2 style=\"margin-top: 0.0000pt; margin-bottom: 0.0000pt; text-align: justify;\"><span class=\"ez-toc-section\" id=\"What_is_a_grounding_transformer\"><\/span><span style=\"font-size: 16pt;\"><span style=\"line-height: 173%;\"><span style=\"font-family: Cambria;\"><span style=\"font-weight: bold;\"><b><span style=\"font-size: 16.0000pt;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"font-weight: bold;\"><span style=\"font-family: Cambria;\"><a id=\"1\" name=\"1\"><\/a>W<\/span><\/span><\/span><\/span><\/b><b><span style=\"font-size: 16.0000pt;\"><span style=\"font-family: Cambria;\"><span style=\"font-weight: bold;\">was ist <\/span><\/span><\/span><\/b><b><span style=\"font-size: 16.0000pt;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"font-weight: bold;\"><span style=\"font-family: Cambria;\">a <\/span><\/span><\/span><\/span><\/b><b><span style=\"font-size: 16.0000pt;\"><span style=\"font-family: Cambria;\"><span style=\"font-weight: bold;\">Erdungstransformator<\/span><\/span><\/span><\/b><\/span><\/span><\/span><\/span><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 18px;\">Der Erdungstransformator schafft einen k\u00fcnstlichen Neutralpunkt zum Anschluss des Erdungswiderstands. Im Falle eines Erdungsfehlers innerhalb des Systems zeigt er eine hohe Impedanz gegen\u00fcber positiven und negativen Stromfolgen, w\u00e4hrend er eine niedrige Impedanz gegen\u00fcber nullfolgen Stromfolgen bietet. Diese Eigenschaft gew\u00e4hrleistet einen zuverl\u00e4ssigen Betrieb des Erdungsschutzsystems.<\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 10.5pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 10.5000pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-family: Times New Roman,Times,serif;\"><strong><span style=\"font-size: 16px;\"><span style=\"color: #e74c3c;\">Mehr lesen:\u00a0<\/span><a href=\"https:\/\/www.daelimtransformer.com\/de\/3-phase-pad-mounted-transformer.html\" target=\"_blank\" rel=\"noopener\"><span style=\"color: #2ecc71;\">3-Phasen-Pad-Montierter Transformator-Daelim Belefic<\/span><\/a><\/span><\/strong><\/span><\/span><\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><img decoding=\"async\" style=\"width: 650px; height: 594px; border-width: 3px; border-style: solid; margin: 5px;\" title=\"grounding-transformer1\" src=\"\/media\/115\/grounding-transformer1.png\" alt=\"grounding-transformer1\" \/><\/p>\n<h2 style=\"margin-top: 0.0000pt; margin-bottom: 0.0000pt; text-align: justify;\"><span class=\"ez-toc-section\" id=\"Types_of_grounding_transformer\"><\/span><span style=\"font-size: 16pt;\"><span style=\"line-height: 173%;\"><span style=\"font-family: Cambria;\"><span style=\"font-weight: bold;\"><b><span style=\"font-size: 16.0000pt;\"><span style=\"font-family: Cambria;\"><span style=\"font-weight: bold;\"><a id=\"2\" name=\"2\"><\/a>Arten von Erdungstransformatoren<\/span><\/span><\/span><\/b><\/span><\/span><\/span><\/span><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 18px;\"><span style=\"font-family: Calibri;\"><span style=\"font-family: Calibri;\">Generell gesagt umfassen Erdungstransformatoren zwei Typen:<\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 18px;\"><span style=\"font-family: Calibri;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"font-family: Calibri;\">1.<\/span><\/span> <span style=\"font-family: \u5b8b\u4f53;\"><span style=\"font-family: Calibri;\">eine sternf\u00f6rmige (Ynd)-verbundene Wicklung<\/span><span style=\"font-family: \u5b8b\u4f53;\">\uff1b<\/span><\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 18px;\"><span style=\"font-family: Calibri;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"font-family: Calibri;\">2.<\/span><\/span> <span style=\"font-family: \u5b8b\u4f53;\"><span style=\"font-family: Calibri;\">eine Zickzack (Zn)-verbundene Wicklung<\/span><span style=\"font-family: \u5b8b\u4f53;\">\uff1b<\/span><\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 18px;\"><span style=\"font-family: Calibri;\"><span style=\"font-family: Calibri;\">Darunter eine<\/span>\u00a0<span style=\"font-family: Calibri;\">2<\/span><span style=\"font-family: \u5b8b\u4f53;\">\u00a0<span style=\"font-family: Calibri;\">w<\/span><\/span><span style=\"font-family: Calibri;\">Wye-verbundene Erdtransformatoren werden aus mehreren Gr\u00fcnden h\u00e4ufiger und beliebter bei Kunden eingesetzt:<\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 18px;\"><span style=\"font-family: Calibri;\"><span style=\"font-family: Calibri;\">1. Es wird allgemein angenommen, dass die Teile des Doppelwicklungs-Transformators leichter auszutauschen oder aufzur\u00fcsten sind, nachdem sie besch\u00e4digt wurden.<\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 18px;\"><span style=\"font-family: Calibri;\"><span style=\"font-family: Calibri;\">2. Die Designer sind mit dem Design von Doppelwicklungs-Transformatoren vertrauter, aber weniger vertraut mit dem Design der Zickzack-Konfiguration. Daher wird der Doppelwicklungs-Transformer beliebter und verbreiteter sein.<\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 18px;\"><span style=\"font-family: Calibri;\"><span style=\"font-family: Calibri;\">3. Wye- <\/span><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"font-family: Calibri;\">\u2013<\/span><\/span><span style=\"font-family: Calibri;\">verbundene Doppelwicklungs-Transformatoren k\u00f6nnen f\u00fcr sekund\u00e4re Lasten und Messungen verwendet werden, w\u00e4hrend das Zickzack-Design dies nicht kann.<\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 18px;\"><span style=\"font-family: Calibri;\"><span style=\"font-family: Calibri;\">4. Nicht alle Hersteller werden <strong><a href=\"https:\/\/www.daelimtransformer.com\/de\/zig-zag-grounding-transformer.html\">Zickzack-Erdtransformatoren bereitstellen.<\/a><\/strong>.<\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-family: Times New Roman,Times,serif;\"><strong><span style=\"font-size: 16px;\"><span style=\"color: #e74c3c;\">Vielleicht genie\u00dfen:\u00a0<\/span><a href=\"https:\/\/www.daelimtransformer.com\/de\/2500-kva-transformer.html\" target=\"_blank\" rel=\"noopener\"><span style=\"color: #2ecc71;\">Der umfassende Leitfaden f\u00fcr 2500KVA Transformatoren<\/span><\/a><\/span><\/strong><\/span><\/p>\n<h2 style=\"margin-top: 0.0000pt; margin-bottom: 0.0000pt; text-align: justify;\"><span class=\"ez-toc-section\" id=\"What_is_the_purpose_of_grounding_transformer\"><\/span><span style=\"font-size: 16pt;\"><span style=\"line-height: 173%;\"><span style=\"font-family: Cambria;\"><span style=\"font-weight: bold;\"><b><span style=\"font-size: 16.0000pt;\"><span style=\"font-family: Cambria;\"><span style=\"font-weight: bold;\"><a id=\"3\" name=\"3\"><\/a>Was ist der Zweck eines Erdungstransformators?<\/span><\/span><\/span><\/b><\/span><\/span><\/span><\/span><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 18px;\"><span style=\"font-family: Calibri;\"><span style=\"font-family: Calibri;\">Erdtransformatoren k\u00f6nnen einen Erdungsweg f\u00fcr ungeerdete Systeme bereitstellen oder verwendet werden, wenn die Neutralleitung des Systems ausf\u00e4llt und nicht verf\u00fcgbar ist. Der Zweck der Verwendung von Erdtransformatoren oder deren Funktionen sind wie folgt:<\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 18px;\"><span style=\"font-family: Calibri;\"><span style=\"font-family: Calibri;\">1. Wenn der Transformator geerdet ist, die Amplitude der transienten \u00dcberspannung begrenzen;<\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 18px;\"><span style=\"font-family: Calibri;\"><span style=\"font-family: Calibri;\">2. Einen relativ niederohmigen Erdungsweg f\u00fcr den Transformator bereitstellen, um den Neutralpunkt des Systems auf oder nahe dem Erdpotential zu halten;<\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 18px;\"><span style=\"font-family: Calibri;\"><span style=\"font-family: Calibri;\">3. Stromquelle w\u00e4hrend eines Erdschlusses bereitstellen;<\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 18px;\"><span style=\"font-family: Calibri;\"><span style=\"font-family: Calibri;\">4. Unter speziellen Umst\u00e4nden die Phase-Neutral-Last verbinden.<\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><strong><span style=\"font-size: 10.5pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 10.5000pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 16px;\"><span style=\"font-family: Times New Roman,Times,serif;\"><span style=\"color: #e74c3c;\">Jetzt erh\u00e4ltlich:<\/span><a href=\"https:\/\/www.daelimtransformer.com\/de\/a-high-voltage-transformer-price.html\" target=\"_blank\" rel=\"noopener\"><span style=\"color: #2ecc71;\">Leitfaden f\u00fcr Hochspannungstransformatoren im Jahr 2022<\/span><\/a><\/span><\/span><\/span><\/span><\/span><\/span><\/strong><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><img decoding=\"async\" style=\"width: 600px; height: 451px; border-width: 4px; border-style: solid; margin: 5px;\" title=\"erd-transformator2.\" src=\"\/media\/115\/grounding-transformer2.png\" alt=\"erd-transformator2.\" \/><\/p>\n<h2 style=\"margin-top: 0.0000pt; margin-bottom: 0.0000pt; text-align: justify;\"><span class=\"ez-toc-section\" id=\"Disadvantages_of_transformer_neutral_point_ungrounded_operation\"><\/span><span style=\"font-size: 16pt;\"><span style=\"line-height: 173%;\"><span style=\"font-family: Cambria;\"><span style=\"font-weight: bold;\"><b><span style=\"font-size: 16.0000pt;\"><span style=\"font-family: Cambria;\"><span style=\"font-weight: bold;\"><a id=\"4\" name=\"4\"><\/a>Nachteile des ungenutzten Betriebs des Transformator-Neutralpunkts<\/span><\/span><\/span><\/b><\/span><\/span><\/span><\/span><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 18px;\"><span style=\"font-family: Calibri;\"><span style=\"font-family: Calibri;\">Es gibt einen Punkt in der Wicklung des Transformators, der dem Absolutwert der Spannung zwischen den externen Anschl\u00fcssen entspricht, und dieser Punkt wird als Neutralpunkt bezeichnet. Der Betriebsmodus des Neutralpunkts des Transformators wird in geerdeten und ungeerdeten Neutralpunktbetrieb unterteilt, die folgende Nachteile aufweisen:<\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 18px;\"><span style=\"font-family: Calibri;\"><span style=\"font-family: Calibri;\">1. <\/span><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"font-family: Calibri;\">I<\/span><\/span><span style=\"font-family: Calibri;\">Anforderungen an das Isolationsniveau und hohe Kosten.<\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 18px;\"><span style=\"font-family: Calibri;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"font-family: Calibri;\">Wenn eine einphasige Erdung auftritt, steigt die nicht fehlerhafte Spannung um <\/span><span style=\"font-family: \u5b8b\u4f53;\">\u221a<\/span><span style=\"font-family: Calibri;\">3 Mal. Daher ist das Isolationsniveau der Ger\u00e4te in diesem Stromnetz hoch und die Kosten sind hoch.<\/span><\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 18px;\"><span style=\"font-family: Calibri;\"><span style=\"font-family: Calibri;\">2. Es besteht die Gefahr von Lichtbogen-Erd\u00fcberspannung.<\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 18px;\"><span style=\"font-family: Calibri;\"><span style=\"font-family: Calibri;\">Wenn der einphasige Erdungsstrom nicht gro\u00df ist, wird der Lichtbogen erl\u00f6schen und der Fehler wird verschwinden, wenn der Strom durch den Nullwert flie\u00dft. Wenn der einphasige Erdungsstrom gr\u00f6\u00dfer als 30 Ampere ist, wird ein stabiler Lichtbogen erzeugt, der einen kontinuierlichen Lichtbogen-Erdung bildet, was die Ger\u00e4te besch\u00e4digt und zu einem Zwei- oder sogar Dreiphasen-Kurzschluss f\u00fchren kann. <\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 18px;\"><span style=\"font-family: Calibri;\"><span style=\"font-family: Calibri;\">3. Die Auswahl des Erdungsrelais-Schutzes ist schwierig.<\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 18px;\"><span style=\"font-family: Calibri;\"><span style=\"font-family: Calibri;\">Da es schwierig ist, empfindlichen und selektiven Schutz zu realisieren, insbesondere in dem mit Lichtbogend\u00e4mpfer geerdeten Stromnetz.<\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 18px;\"><span style=\"font-family: Calibri;\"><span style=\"font-family: Calibri;\">4. Die Unterbrechung kann Resonanz\u00fcberspannung verursachen.<\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 18px;\"><span style=\"font-family: Calibri;\"><span style=\"font-family: Calibri;\">Das Brechen des Drahts, das Schalten zu verschiedenen Zeitpunkten und das Schmelzen der Sicherung zu verschiedenen Zeitpunkten f\u00fchren zu Ferroresonanz\u00fcberspannung. Die durch die Unterbrechung verursachte Resonanz\u00fcberspannung kann zur Explosion des \u00dcberspannungsableiters, zur Umkehrung der Phasensequenz des Transformatorenlasts und zum Isolationsdurchschlag elektrischer Ger\u00e4te f\u00fchren.<\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 18px;\"><span style=\"font-family: Calibri;\"><span style=\"font-family: Calibri;\">5. Resonanz\u00fcberspannung des elektromagnetischen Spannungstransformators<\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 18px;\"><span style=\"font-family: Calibri;\"><span style=\"font-family: Calibri;\">Aufgrund der Asymmetrie der Netzparameter f\u00fchrt die Ablenkung des Neutralpunkts h\u00e4ufig zu ferro magnetischer Resonanz\u00fcberspannung, die h\u00e4ufig die Hochvoltfusion des elektromagnetischen Spannungstransformators ausl\u00f6st oder den Transformator selbst besch\u00e4digt.<\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><strong><span style=\"font-size: 16px;\"><span style=\"font-family: Times New Roman,Times,serif;\"><span style=\"color: #e74c3c;\">Erfahren Sie mehr:<\/span><a href=\"https:\/\/www.daelimtransformer.com\/de\/electrical-transformer.html\" target=\"_blank\" rel=\"noopener\"><span style=\"color: #2ecc71;\">Grundlagen des elektrischen Transformators<\/span><\/a><\/span><\/span><\/strong><\/p>\n<h2 style=\"margin-top: 0.0000pt; margin-bottom: 0.0000pt; text-align: justify;\"><img decoding=\"async\" style=\"width: 500px; height: 376px; border-width: 5px; border-style: solid; margin: 5px;\" title=\"grounding-transformer3\" src=\"\/media\/115\/grounding-transformer3.png\" alt=\"grounding-transformer3\" \/><\/h2>\n<h2 style=\"margin-top: 0.0000pt; margin-bottom: 0.0000pt; text-align: justify;\"><span class=\"ez-toc-section\" id=\"Advantages_of_transformer_neutral_point_ungrounded_operation\"><\/span><span style=\"font-size: 16pt;\"><span style=\"line-height: 173%;\"><span style=\"font-family: Cambria;\"><span style=\"font-weight: bold;\"><b><span style=\"font-size: 16.0000pt;\"><span style=\"font-family: Cambria;\"><span style=\"font-weight: bold;\"><a id=\"5\" name=\"5\"><\/a>Vorteile des ungenutzten Betriebs des Transformator-Neutralpunkts<\/span><\/span><\/span><\/b><\/span><\/span><\/span><\/span><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 18px;\"><span style=\"font-family: Calibri;\"><span style=\"font-family: Calibri;\">1. Hohe Zuverl\u00e4ssigkeit der Stromversorgung<\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 18px;\"><span style=\"font-family: Calibri;\"><span style=\"font-family: Calibri;\">Wenn ein einphasiger Erdschluss im Stromnetz auftritt, ist die \u00c4nderung der Dreiphasenspannung und der Phasenstr\u00f6me sehr gering. Da es keinen Kurzschluss darstellt, hat der einphasige Erdungsstrom nur wenig Einfluss auf die Stromversorgung der Nutzer. Der Fehler muss jedoch in kurzer Zeit (normalerweise 2 Stunden) schnell beseitigt werden, um eine Ausweitung zu vermeiden. Da es in kurzer Zeit nicht ausl\u00f6st, ist die Zuverl\u00e4ssigkeit der Stromversorgung hoch.<\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 18px;\"><span style=\"font-family: Calibri;\"><span style=\"font-family: Calibri;\">2. Die St\u00f6rung des Kommunikations- und Signalsystems ist gering.<\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 18px;\"><span style=\"font-family: Calibri;\"><span style=\"font-family: Calibri;\">Wenn der dreiphasige Betrieb im Wesentlichen symmetrisch ist, ist das von der Leitungen zum umgebenden Raum gebildete elektromagnetische Feld nicht gro\u00df und st\u00f6rt die Kommunikations- und Signalsysteme nicht. Ebenso ist der einphasige Erdungsstrom des Stromkreises mit ungrounded Neutralpunkt des Transformators aufgrund seiner geringen St\u00e4rke ebenfalls gering, sodass die Schwachstromst\u00f6rung benachbarter Kommunikationsleitungen und Signalsysteme ebenfalls gering ist. Der einphasige Erdungsbogen kann f\u00fcr kleine Systeme mit ungrounded Zentrum in l\u00e4ndlichen Stromnetzen automatisch gel\u00f6scht werden.<\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 18px;\"><strong><span style=\"font-family: Times New Roman,Times,serif;\"><span style=\"color: #e74c3c;\">Vielleicht genie\u00dfen:<\/span><a href=\"https:\/\/www.daelimtransformer.com\/de\/what-kind-of-distribution-is-best-for-you.html\" target=\"_blank\" rel=\"noopener\">\u00a0<span style=\"color: #2ecc71;\">Wie w\u00e4hlt man den besten Verteilungstransformator aus?<\/span><\/a><\/span><\/strong><\/span><\/p>\n<h2 style=\"margin-top: 0.0000pt; margin-bottom: 0.0000pt; text-align: justify;\"><span class=\"ez-toc-section\" id=\"What_is_neutral_grounding_transformer\"><\/span><span style=\"font-size: 16pt;\"><span style=\"line-height: 173%;\"><span style=\"font-family: Cambria;\"><span style=\"font-weight: bold;\"><b><span style=\"font-size: 16.0000pt;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"font-weight: bold;\"><span style=\"font-family: Cambria;\"><a id=\"6\" name=\"6\"><\/a>W<\/span><\/span><\/span><\/span><\/b><b><span style=\"font-size: 16.0000pt;\"><span style=\"font-family: Cambria;\"><span style=\"font-weight: bold;\">Was ist ein Neutral-Erdungstransformator<\/span><\/span><\/span><\/b><\/span><\/span><\/span><\/span><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 18px;\"><span style=\"font-family: Calibri;\"><span style=\"font-family: Calibri;\">Die Neutral-Erdung des Transformators besteht darin, den Anschluss eines der Wicklungen des Transformators fest mit der Erde zu verbinden. Er dient haupts\u00e4chlich dazu, \u00dcberspannungen im Stromsystem zu verhindern, die die Isolierung der Transformatorwicklungen besch\u00e4digen k\u00f6nnten. Meistens bezieht sich dies auf die Erdung des Neutralpunkts auf der Hochspannungseite. Die Niederspannungsneutral-Erdung wird normalerweise im Verteilernetz verwendet.<\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><strong><span style=\"font-family: Times New Roman,Times,serif;\"><span style=\"font-size: 16px;\"><span style=\"color: #e74c3c;\">Lese meinen Artikel \u00fcber:\u00a0<\/span><a href=\"https:\/\/www.daelimtransformer.com\/de\/skid-mount-transformer-solution-with3-phase-pad-mounted-transformer-inside.html\" target=\"_blank\" rel=\"noopener\"><span style=\"color: #2ecc71;\">Skid-mount Transformatorl\u00f6sung mit einem 3-phasigen pad-mounted Transformator im Inneren.<\/span><\/a><\/span><\/span><\/strong><\/p>\n<h2 style=\"margin-top: 0.0000pt; margin-bottom: 0.0000pt; text-align: justify;\"><span class=\"ez-toc-section\" id=\"Characteristics_of_grounding_transformer\"><\/span><span style=\"font-size: 16pt;\"><span style=\"line-height: 173%;\"><span style=\"font-family: Cambria;\"><span style=\"font-weight: bold;\"><b><span style=\"font-size: 16.0000pt;\"><span style=\"font-family: Cambria;\"><span style=\"font-weight: bold;\"><a id=\"7\" name=\"7\"><\/a>Eigenschaften von Erdungstransformatoren<\/span><\/span><\/span><\/b><\/span><\/span><\/span><\/span><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 18px;\"><span style=\"font-family: Calibri;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"font-family: Calibri;\">1.<\/span><\/span><span style=\"font-family: Calibri;\">\u00a0Wenn das Stromnetz im normalen Betrieb ist, ist es lange Zeit im Leerlaufzustand; Wenn der Erdschluss auftritt, wird es f\u00fcr kurze Zeit \u00fcberlastet;<\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 18px;\"><span style=\"font-family: Calibri;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"font-family: Calibri;\">2.<\/span><\/span><span style=\"font-family: Calibri;\">Der Laststrom, der durch die Transformatorwicklung flie\u00dft, ist Nullfolgenstrom, sodass die Nullfolgeimpedanz des Transformators wichtiger ist.<\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><strong><span style=\"font-size: 16px;\"><span style=\"font-family: Times New Roman,Times,serif;\"><span style=\"color: #e74c3c;\">Erfahren Sie mehr:\u00a0<\/span><a href=\"https:\/\/www.daelimtransformer.com\/de\/different-types-of-transformers.html\" target=\"_blank\" rel=\"noopener\"><span style=\"color: #2ecc71;\">Wie viel wissen Sie \u00fcber die verschiedenen Arten von Transformatoren?<\/span><\/a><\/span><\/span><\/strong><\/p>\n<h2 style=\"margin-top: 0.0000pt; margin-bottom: 0.0000pt; text-align: justify;\"><span class=\"ez-toc-section\" id=\"Harm_and_treatment_measures_of_oil_leakage_in_grounding_transformer\"><\/span><span style=\"font-size: 16pt;\"><span style=\"line-height: 173%;\"><span style=\"font-family: Cambria;\"><span style=\"font-weight: bold;\"><b><span style=\"font-size: 16.0000pt;\"><span style=\"font-family: Cambria;\"><span style=\"font-weight: bold;\"><a id=\"8\" name=\"8\"><\/a>Sch\u00e4den und Ma\u00dfnahmen zur Behandlung von \u00d6lverlusten in Erdungstransformatoren<\/span><\/span><\/span><\/b><\/span><\/span><\/span><\/span><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 18px;\"><span style=\"font-family: Calibri;\"><span style=\"font-family: Calibri;\">1. Spezifische Gefahren des \u00d6lverlusts von Erdungstransformatoren:<\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 18px;\"><span style=\"font-family: Calibri;\"><span style=\"font-family: Calibri;\"><span style=\"color: #000000;\">(1) Der \u00d6lverlust des Erdungstransformators wirkt sich zun\u00e4chst auf das Erscheinungsbild aus und macht den Transformator unattraktiv; Zweitens, da der Transformator gestoppt werden muss, um das Leckageproblem zu beseitigen, verursacht dies bestimmte wirtschaftliche Verluste. Schlie\u00dflich kann, wenn sich viele \u00d6lflecken auf dem Boden des Erdungstransformators befinden, eine Brandgefahr entstehen und die Lebenssicherheit der Arbeiter gef\u00e4hrden.<\/span><\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 18px;\"><span style=\"font-family: Calibri;\"><span style=\"font-family: Calibri;\"><span style=\"color: #000000;\">(2) In gewissem Ma\u00dfe wird der \u00d6lverlust des Erdungstransformators die Inspektion und Beurteilung des Wartungspersonals bez\u00fcglich des Dichtheitszustands im Transformator\u00f6lbeh\u00e4lter st\u00f6ren.<\/span><\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 18px;\"><span style=\"font-family: Calibri;\"><span style=\"font-family: Calibri;\"><span style=\"color: #000000;\">(3) Wenn der \u00d6lstand aufgrund von Leckagen sinkt, kann das Betreiben der stromf\u00fchrenden Verbindung und des Schalters ohne Eintauchen in Isolier\u00f6l zu Durchschl\u00e4gen, Kurzschl\u00fcssen, Verbrennungen und sogar zum Explodieren von Ger\u00e4ten f\u00fchren.<\/span><\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 18px;\"><span style=\"font-family: Calibri;\"><span style=\"font-family: Calibri;\"><span style=\"color: #000000;\">(4) Nach dem \u00d6laustritt des Erdungstransformators wird das Eindringen von Au\u00dfenluft und Feuchtigkeit die Isolierleistung verringern, die Alterung beschleunigen und den sicheren und zuverl\u00e4ssigen Betrieb des Transformators beeintr\u00e4chtigen.<\/span><\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 18px;\"><span style=\"font-family: Calibri;\"><span style=\"font-family: Calibri;\">(5) Au\u00dferdem kann es, wenn am oberen Ende des \u00d6ltanks, wie am L\u00fcftungsstopfen und am leitenden Kopf des Geh\u00e4uses, ein Dichtungsdefekt vorliegt oder wenn sich Sandl\u00f6cher am oberen Ende des \u00d6ltanks und dessen Kopf befinden, selbst wenn kein \u00d6laustritt aufgrund der hohen Position vorliegt, zu einem Eindringen von Regen und Feuchtigkeit kommen, was zu einer Verschlechterung der Isolierleistung und sogar zu einem Isolationsdurchbruch und einem Windungsbrand f\u00fchren kann.<\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 18px;\"><span style=\"font-family: Calibri;\"><span style=\"font-family: Calibri;\">2. Ma\u00dfnahmen zur Kontrolle des \u00d6laustritts des Erdungstransformators<\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 18px;\"><span style=\"font-family: Calibri;\"><span style=\"font-family: Calibri;\">Vor der Behandlung von \u00d6laustritten muss eine sorgf\u00e4ltige Analyse durchgef\u00fchrt werden, um die Ursache des Austritts und den genauen Austrittsort zu ermitteln. F\u00fcr die vorhandenen \u00d6lflecken sollten diese zun\u00e4chst mit Waschmittel gr\u00fcndlich gereinigt, dann mit sauberem Wasser abgesp\u00fclt und schlie\u00dflich wiederholt mit einem sauberen Tuch gereinigt werden, um den genauen Standort des Austritts zu finden.<\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 18px;\"><span style=\"font-family: Calibri;\"><span style=\"font-family: Calibri;\">Wenn ein \u00d6laustritt im oberen Teil des \u00d6ltanks des Erdtransformators festgestellt wird, muss nur eine kleine Menge \u00d6l abgelassen werden, um geschwei\u00dft zu werden. Wird ein Leck im unteren Teil des \u00d6ltanks gefunden, kann aufgrund der Abfallmenge an \u00d6l, die aus dem h\u00e4ngenden Kern abflie\u00dft, und der Einschr\u00e4nkung der Standortbedingungen Schwei\u00dfen mit \u00d6l angewendet werden. Das Reparaturschwei\u00dfen mit \u00d6l sollte unter der Bedingung durchgef\u00fchrt werden, dass der \u00d6laustritt nicht signifikant ist, andernfalls sollte durch Vakuumieren und \u00d6lablassen ein Unterdruck erzeugt werden, und der Vakuumgrad des Unterdrucks sollte nicht zu hoch sein. Es ist ratsam, den inneren und \u00e4u\u00dferen Druck gleich zu halten, um das Einsaugen von geschmolzenem Eisen zu vermeiden. Bei Reparaturarbeiten sollte der \u00d6lfleck am Schwei\u00dfplatz entfernt werden, und es ist am besten, mit alkalischem Wasser abzusp\u00fclen und dann zu trocknen; Achten Sie darauf, w\u00e4hrend des Schwei\u00dfens das Eindringen und Feuer zu verhindern, und die Schwei\u00dfposition muss unterhalb des \u00d6lstandes liegen; Intermittierendes und schnelles Punkteschwei\u00dfen sollte beim Schwei\u00dfen angewendet werden, und die Lichtbogenbrenndauer <\/span><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"font-family: Calibri;\">die Zeit sollte auf 10 Sekunden begrenzt werden<\/span><span style=\"font-family: \u5b8b\u4f53;\">\uff5e<\/span><span style=\"font-family: Calibri;\">20s. Dauerhaftes Schwei\u00dfen \u00fcber l\u00e4ngere Zeit ist absolut nicht erlaubt.<\/span><\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 18px;\"><span style=\"font-family: Calibri;\"><span style=\"font-family: Calibri;\">Beim Schwei\u00dfen von Poren mit schwerem \u00d6lverlust sollten diese vor dem Schwei\u00dfen mit Eisendraht verschlossen oder genietet werden; Beim Schwei\u00dfen in der N\u00e4he der Dichtgummi-Dichtungen oder anderer empfindlicher Teile sollten K\u00fchl- und Schutzma\u00dfnahmen ergriffen werden.<\/span><\/span><\/span><\/p>\n<p><strong><span style=\"font-size: 16px;\"><span style=\"font-family: Times New Roman,Times,serif;\"><span style=\"color: #e74c3c;\">Weiterlesen:<\/span>\u00a0<a href=\"https:\/\/www.daelimtransformer.com\/de\/substation-transformer-daelim-belefic.html\" target=\"_blank\" rel=\"noopener\"><span style=\"color: #2ecc71;\">Was Sie 2022 \u00fcber Transformatoren von Umspannwerken wissen m\u00fcssen\u00a0<\/span><\/a><\/span><\/span><\/strong><\/p>\n<p><iframe title=\"YouTube Video-Player\" src=\"https:\/\/www.youtube.com\/embed\/vnNLzecd1hM\" width=\"100%\" height=\"315\" frameborder=\"0\" allowfullscreen=\"allowfullscreen\"><\/iframe><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 10.5pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 10.5000pt;\"><span style=\"font-family: Calibri;\">Daelim Transformatoren stellt hochwertige Erdtransformatoren her. Die von Daelim produzierten Transformatoren haben die Vorteile eines sch\u00f6nen Erscheinungsbildes und einer hervorragenden Qualit\u00e4t und erf\u00fcllen viele internationale Standards wie <a href=\"https:\/\/www.daelimtransformer.com\/de\/certificate.html\">CSA, ANSI\/IEEE, IEC, UL<\/a>, usw. <a href=\"https:\/\/www.daelimtransformer.com\/de\/pole-mounted-single-phase-transformer.html\">Einphasen-Mastenmontierter Transformator<\/a>, <a href=\"https:\/\/www.daelimtransformer.com\/de\/product-single-phase-pad-mounted-transformer.html\">Einphasen-Bodenmontierter Transformator<\/a>, Drehstrom-Pad-Montage-Transformator und <a href=\"https:\/\/www.daelimtransformer.com\/de\/substation-transformer.html\">Umspannungstransformator<\/a>sind allesamt Bestseller, die in gro\u00dfen Mengen in die USA, nach Kanada, Mexiko und viele andere amerikanische L\u00e4nder und Regionen verkauft werden.<\/span><\/span><\/span><\/span><\/p>\n<p><!-- \u5de6\u53f3\u56fe\u6587--><\/p>\n<p><!-- \u8c46\u8150\u5757\u56fe\u6587\u4e0a\u4e0b--><\/p>\n<p><!--\u6587\u5b57\u6a21\u5757--><\/p>\n<p><!-- \u5de6\u53f3\u56fe\u6587--><\/p>\n<p><!--\u6587\u5b57\u6a21\u5757--><\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>In the three-phase power system, grounding transformer plays the role and function of auxiliary transformer. The function of a grounding transformer is to provide grounding mode for ungrounded delta connect or wye connect. Therefore, a ground transformer is also a very important part of the power grid grounding system. Daelim Transformer\u00a0is a transformer manufacturer with [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":7235,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[279],"tags":[],"class_list":["post-7234","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articles-news"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/posts\/7234","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/comments?post=7234"}],"version-history":[{"count":0,"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/posts\/7234\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/media\/7235"}],"wp:attachment":[{"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/media?parent=7234"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/categories?post=7234"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/tags?post=7234"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}