{"id":7404,"date":"2026-01-05T08:41:34","date_gmt":"2026-01-05T08:41:34","guid":{"rendered":"https:\/\/daelimtransformer.com\/?p=7404"},"modified":"2026-03-13T07:55:02","modified_gmt":"2026-03-13T07:55:02","slug":"csa-c88-standard-for-power-transformers","status":"publish","type":"post","link":"https:\/\/www.daelimtransformer.com\/de\/csa-c88-standard-for-power-transformers.html","title":{"rendered":"CSA C88 Standard f\u00fcr Leistungstransformatoren"},"content":{"rendered":"<div id=\"contentMain\" class=\"article-content\">\n<p class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">CSA C88 ist ein umfassender Standard f\u00fcr Leistungstransformatoren und Reaktoranschl\u00fcsse in Kanada und weltweit.<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><img decoding=\"async\" style=\"width: 450px; height: 450px;\" title=\"csa c88 Standardtransformator\" src=\"\/media\/115\/csa-c88-standard-power-transformer.webp\" alt=\"csa c88 Standardtransformator\" \/><br \/>\n<span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\"><span style=\"font-family: Arial, Helvetica, sans-serif;\">Da<\/span><\/span><\/span><\/span><\/span><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\"><span style=\"font-family: Arial, Helvetica, sans-serif;\">elim <\/span><\/span><\/span><\/span><\/span><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\"><span style=\"font-family: Arial, Helvetica, sans-serif;\">ist ein professioneller Anbieter von CSA-Standardtransformatoren. CSA hat nicht nur eine Produktzertifizierung, sondern ist auch cUL-gelistet. Es kann CSA- und cUL-Beschriftungsdienste f\u00fcr Ihren Transformator bereitstellen.<\/span><\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Dieser Standard ist f\u00fcr Blitzimpuls-Isolationsraten von 110 kV bis 1950 kV geeignet, die h\u00e4ufig in Freiluftbushings vorkommen. Die Transformatoren und Reaktoren sind speziell f\u00fcr diese Art von Ger\u00e4ten konzipiert.<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><a href=\"https:\/\/www.daelimtransformer.com\/de\/contact.html\" target=\"_blank\" rel=\"noopener\"><img decoding=\"async\" style=\"float: right; width: 300px; height: 442px;\" title=\"csa Transformator\" src=\"\/media\/115\/csa-transformer_1.webp\" alt=\"csa Transformator\" \/><\/a><br \/>\n<span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Es bietet Spezifikationen f\u00fcr:<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<ol>\n<li class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">fl\u00fcssigkeitsgef\u00fcllte Transformatoren<\/span><\/span><\/span><\/span><\/span><\/span><\/li>\n<li class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Autotransformatoren<\/span><\/span><\/span><\/span><\/span><\/span><\/li>\n<li class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Booster-Transformatoren<\/span><\/span><\/span><\/span><\/span><\/span><\/li>\n<li class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Lastumschalttransformatoren<\/span><\/span><\/span><\/span><\/span><\/span><\/li>\n<\/ol>\n<p class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Erfahren Sie mehr \u00fcber die C88-Spezifikationen und Verfahren der CSA. Dieser Standard wird speziell Transformatoren und Reaktoren behandeln.<\/span><\/span><\/span><\/span>\u00a0<\/span><\/span><\/p>\n<p class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Wir bekommen einen Einblick, wie diese Regeln sorgf\u00e4ltig von der Canadian Standards Association entwickelt wurden. Wir werden auch \u00fcber die g\u00e4ngige Praxis der Verwendung von Transformatoren und Reaktoren sprechen.<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Mit Hilfe dieses Leitfadens werden wir ein besseres Verst\u00e4ndnis des kanadischen Stromnetzes haben.<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<h2 style=\"margin-bottom: 13px; text-align: left;\"><span class=\"ez-toc-section\" id=\"What_is_CSA_C88_Standard\"><\/span><span style=\"font-size: 18pt;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"font-weight: bold;\"><b><span style=\"font-size: 17.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-weight: bold;\"><span style=\"font-style: normal;\"><a id=\"1\" name=\"1\"><\/a>Was ist der CSA C88 Standard?<\/span><\/span><\/span><\/span><\/span><\/b><\/span><\/span><\/span><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><img decoding=\"async\" style=\"width: 650px; height: 433px;\" title=\"csa c88\" src=\"\/media\/115\/csa-c88.webp\" alt=\"csa c88\" \/><br \/>\n<span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Die CSA C88-Normen sind eine Reihe von Regeln zur \u00dcberpr\u00fcfung und Pr\u00fcfung von Durchf\u00fchrungen in Leistungstransformatoren und Reaktoren in Kanada und weltweit.\u00a0<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Historisch gesehen wurde es 2016 von der CSA \u00f6ffentlich zug\u00e4nglich gemacht.<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Die technischen Standards der CSA C88 umfassen die folgenden Bereiche:<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<ul>\n<li class=\"p\" style=\"margin-bottom: 13px; text-align: left;\" value=\"50\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">\u00f6lgef\u00fcllte Transformatoren.<\/span><\/span><\/span><\/span><\/span><\/span><\/li>\n<li class=\"p\" style=\"margin-bottom: 13px; text-align: left;\" value=\"50\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">geerdete Transformatoren<\/span><\/span><\/span><\/span><\/span><\/span><\/li>\n<li class=\"p\" style=\"margin-bottom: 13px; text-align: left;\" value=\"50\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">lastver\u00e4ndernde Transformatoren<\/span><\/span><\/span><\/span><\/span><\/span><\/li>\n<li class=\"p\" style=\"margin-bottom: 13px; text-align: left;\" value=\"50\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Phasenverschiebungs-Transformatoren<\/span><\/span><\/span><\/span><\/span><\/span><\/li>\n<li class=\"p\" style=\"margin-bottom: 13px; text-align: left;\" value=\"50\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Autotransformatoren<\/span><\/span><\/span><\/span><\/span><\/span><\/li>\n<li class=\"p\" style=\"margin-bottom: 13px; text-align: left;\" value=\"50\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Booster-Transformatoren<\/span><\/span><\/span><\/span><\/span><\/span><\/li>\n<li class=\"p\" style=\"margin-bottom: 13px; text-align: left;\" value=\"50\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Serien-Spannungsregler<\/span><\/span><\/span><\/span><\/span><\/span><\/li>\n<li class=\"p\" style=\"margin-bottom: 13px; text-align: left;\" value=\"50\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Shunt-Reaktoren<\/span><\/span><\/span><\/span><\/span><\/span><\/li>\n<\/ul>\n<p class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Der Technische Ausschuss f\u00fcr Leistungstransformatoren ist f\u00fcr diesen Standard verantwortlich. Daher wurde er vom Strategischen Lenkungsausschuss f\u00fcr Elektrotechnik und EMV weitgehend genehmigt.<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Laut der Richtlinie der CSA zur Standardisierung - Verhaltenskodex f\u00fcr gute Praxis in der Standardisierung, ist \u201csubstantial agreement\u201d die Definition von Konsens, die bei der Entwicklung des C88-Richtlinienhandbuchs verwendet wird.<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><b><span style=\"font-size: 16.0000pt;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"color: #00b050;\"><span style=\"font-weight: bold;\"><span style=\"font-style: normal;\"><span style=\"font-family: Arial, Helvetica, sans-serif;\">Erfahren Sie mehr \u00fcber <\/span><\/span><\/span><\/span><\/span><\/span><\/b><a href=\"https:\/\/www.daelimtransformer.com\/de\/csa-c227.4-national-standard-of-canada.html\" target=\"_blank\" rel=\"noopener\"><b><u><span class=\"15\" style=\"font-size: 16.0000pt;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"color: #ff0000;\"><span style=\"font-weight: bold;\"><span style=\"text-decoration: underline;\"><span style=\"text-underline: single;\"><span style=\"font-style: normal;\"><span style=\"font-family: Arial, Helvetica, sans-serif;\">CSA-Standards<\/span><\/span><\/span><\/span><\/span><\/span><\/span><\/span><\/u><\/b><\/a><b><span style=\"font-size: 16.0000pt;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"color: #ff0000;\"><span style=\"font-weight: bold;\"><span style=\"font-style: normal;\"><span style=\"font-family: Arial, Helvetica, sans-serif;\">.<\/span><\/span><\/span><\/span><\/span><\/span><\/b><\/span><\/span><\/p>\n<h2 style=\"margin-bottom: 13px; text-align: left;\"><span class=\"ez-toc-section\" id=\"Who_is_CANCSA\"><\/span><span style=\"font-size: 18pt;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"font-weight: bold;\"><b><span style=\"font-size: 17.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-weight: bold;\"><span style=\"font-style: normal;\"><a id=\"2\" name=\"2\"><\/a>Wer ist CAN\/CSA?<\/span><\/span><\/span><\/span><\/span><\/b><\/span><\/span><\/span><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Die Canadian Standards Association (CSA) verantwortete die Erstellung dieses nationalen Standards.\u00a0<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Die CSA wurde traditionell im Jahr 1919 gegr\u00fcndet. Folglich erkannte der Standards Rat von Kanada 1973 die CSA als Mitglied des Nationalen Standardsystems an.\u00a0<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Da ihre Mitglieder alle unbezahlte Freiwillige sind, erhebt sie von der Industrie, die sie reguliert, keinen Cent f\u00fcr das Privileg, Standards zu erstellen und zu zertifizieren.<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Die Vereinigung bietet Zertifizierung und Tests zus\u00e4tzlich zu ihren Aktivit\u00e4ten zur Standardsetzung an. Produkte mit dem CSA-Zeichen werden regelm\u00e4\u00dfig gr\u00fcndlich \u00fcberpr\u00fcft und inspiziert, um sicherzustellen, dass die Zertifizierung weiterhin g\u00fcltig ist.<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Der Standards Rat von Kanada (SCC) ist die oberste Beh\u00f6rde, die f\u00fcr Kanadas Nationales Standardsystem zust\u00e4ndig ist, ein lockerer Zusammenschluss autonomer Gruppen, die auf die Verbesserung des kanadischen Systems der freiwilligen Standardisierung hinarbeiten.<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Nationale Standards von Kanada sollten zun\u00e4chst ein Dokument \u00fcberpr\u00fcfen, bevor es vom Standards Rat von Kanada (SCC) akzeptiert und allgemein anerkannt wird.\u00a0<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Die Genehmigung eines Standards \u00e4ndert nicht den technischen Inhalt des Standards, der weiterhin in der Zust\u00e4ndigkeit des akkreditierten Normungsorgans bleibt.<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Insgesamt verf\u00fcgt die CSA \u00fcber umfangreiche Kenntnisse in der Durchf\u00fchrung von Tests gem\u00e4\u00df wichtigen Branchenstandards wie C88 f\u00fcr Leistungstransformatoren und Reaktoren.<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><b><span style=\"font-size: 16.0000pt;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"color: #00b050;\"><span style=\"font-weight: bold;\"><span style=\"font-style: normal;\"><span style=\"font-family: Arial, Helvetica, sans-serif;\">Weiterlesen: <\/span><\/span><\/span><\/span><\/span><\/span><\/b><a href=\"https:\/\/www.daelimtransformer.com\/de\/3000kva-transformer.html\" target=\"_blank\" rel=\"noopener\"><b><u><span class=\"15\" style=\"font-size: 16.0000pt;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"color: #ff0000;\"><span style=\"font-weight: bold;\"><span style=\"text-decoration: underline;\"><span style=\"text-underline: single;\"><span style=\"font-style: normal;\"><span style=\"font-family: Arial, Helvetica, sans-serif;\">Wie kaufe ich einen 3000kVA Transformator in den USA und Kanada?<\/span><\/span><\/span><\/span><\/span><\/span><\/span><\/span><\/u><\/b><\/a><\/span><\/span><\/p>\n<h2 style=\"margin-bottom: 13px; text-align: left;\"><\/h2>\n<h2 style=\"margin-bottom: 13px; text-align: left;\"><span class=\"ez-toc-section\" id=\"What_is_CSAs_C88-M90_Standard_Version_CSA_Standard_C88-M90_Power_Transformers_and_Reactors_spans_91_pages_and_was_finally_released_in_August_1990\"><\/span><span style=\"font-size: 18pt;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"font-weight: bold;\"><b><span style=\"font-size: 17.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-weight: bold;\"><span style=\"font-style: normal;\"><a id=\"3\" name=\"3\"><\/a>Was ist die C88-M90-Standardschnittstelle von CSA?<\/span><\/span><\/span><\/span><\/span><\/b><\/span><\/span><\/span><br \/>\n<img decoding=\"async\" style=\"width: 650px; height: 433px;\" title=\"csa c88-m90\" src=\"\/media\/115\/csa-c88-m90.webp\" alt=\"csa c88-m90\" \/><br \/>\n<span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Der CSA Standard C88-M90 f\u00fcr Leistungstransformatoren und Reaktoren umfasst 91 Seiten und wurde schlie\u00dflich im August 1990 ver\u00f6ffentlicht.<\/span><\/span><\/span><\/span><\/span><\/span><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Dies ist die neueste Version der Leistungstransformatoren und Reaktoren der Canadian Standards Association.\u00a0<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Es handelt sich um die vierte Auflage (CSA Standard C88). Diese aktualisierte Version ersetzt die \u00e4lteren Modelle von 1947, 1968 und 1979.<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><span style=\"font-size: 18px;\"><span style=\"color: #00b050;\"><strong>Sie k\u00f6nnten genie\u00dfen:<\/strong><\/span><strong><a href=\"https:\/\/www.daelimtransformer.com\/de\/pad-mounted-transformer.html\"><span style=\"color: #c0392b;\"> Bodenmontierter Transformator<\/span><\/a><\/strong><\/span><\/p>\n<h3 style=\"margin-top: 17px; margin-bottom: 17px; text-align: justify;\"><span class=\"ez-toc-section\" id=\"What_are_the_Major_changes_and_revisions_for_this_type_of_Standard\"><\/span><span style=\"font-size: 14pt;\"><span style=\"line-height: 172%;\"><span style=\"font-family: Calibri;\"><b><span style=\"font-size: 14.0000pt;\"><span style=\"font-family: Calibri;\"><a id=\"3.1\" name=\"3.1\"><\/a>Was sind die wesentlichen \u00c4nderungen und \u00dcberarbeitungen f\u00fcr diesen Standardtyp?<\/span><\/span><\/b><\/span><\/span><\/span><span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">a) Gehackte Wellentests wurden nun eliminiert und \u00e4u\u00dfere Luftabst\u00e4nde wurden auch f\u00fcr induzierte, angelegte und Impulstests eingef\u00fchrt.<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">b) Messungen von RIV und scheinbarer Ladung sind nun erforderlich f\u00fcr Transformatoren mit Leistungen \u00fcber 245 Kilovolt. Bei Verwendung eines gezwungenen gerichteten \u00d6lflusses erlaubt dieser Standard einen Temperaturanstieg von 70 \u00b0C bei Wicklungen im Durchschnitt.<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">c) Dieser Standard wurde urspr\u00fcnglich f\u00fcr Zweuwicklungstransformatoren entwickelt, kann jedoch allgemein mit anderen Transformator-Konfigurationen verwendet werden.\u00a0<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Dazu geh\u00f6ren:\u00a0<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<ul>\n<li class=\"p\" style=\"margin-bottom: 13px; text-align: left;\" value=\"50\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Autotransformatoren<\/span><\/span><\/span><\/span><\/span><\/span><\/li>\n<li class=\"p\" style=\"margin-bottom: 13px; text-align: left;\" value=\"50\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Lastumschalttransformatoren<\/span><\/span><\/span><\/span><\/span><\/span><\/li>\n<li class=\"p\" style=\"margin-bottom: 13px; text-align: left;\" value=\"50\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Shunt-Reaktoren<\/span><\/span><\/span><\/span><\/span><\/span><\/li>\n<li class=\"p\" style=\"margin-bottom: 13px; text-align: left;\" value=\"50\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Serien-Spannungsregler<\/span><\/span><\/span><\/span><\/span><\/span><\/li>\n<\/ul>\n<h2 style=\"margin-bottom: 13px; text-align: left;\"><\/h2>\n<h2 style=\"margin-bottom: 13px; text-align: left;\"><span class=\"ez-toc-section\" id=\"What_is_CSAs_C88-16_Standard_Version\"><\/span><span style=\"font-size: 18pt;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"font-weight: bold;\"><b><span style=\"font-size: 17.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-weight: bold;\"><span style=\"font-style: normal;\"><a id=\"4\" name=\"4\"><\/a>Was ist die CSA C88-16 Standardversion?<\/span><\/span><\/span><\/span><\/span><\/b><\/span><\/span><\/span><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><img decoding=\"async\" style=\"width: 650px; height: 433px;\" title=\"csa c88-16\" src=\"\/media\/115\/csa-c88-16.webp\" alt=\"csa c88-16\" \/><\/p>\n<p class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Die C88-16-Version ist die f\u00fcnfte Version des CSA-Standards f\u00fcr Leistungstransformatoren und Reaktoren, die 2016 ver\u00f6ffentlicht wurde.<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Diese Ausgabe ersetzt die Version von 1990 sowie die Versionen von 1979, 1968 und 1947 davor.<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Obwohl dieser Standard speziell mit Blick auf Zweuwicklungstransformatoren verfasst wurde, gelten viele seiner Anforderungen auch f\u00fcr andere Transformatorarten wie Autotransformatoren, Lastabgriffwechsel-Transformatoren, Shuntreaktoren und Reihen-Spannungsregler.<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><span style=\"color: #00b050;\"><strong><span style=\"font-size: 18px;\"><span style=\"font-family: Calibri;\"><span style=\"font-family: Arial;\"><span style=\"font-style: normal;\">Erfahren Sie mehr \u00fcber <\/span><\/span><\/span><\/span><\/strong><\/span><strong><span style=\"font-size: 18px;\"><span style=\"font-family: Calibri;\"><span style=\"font-family: Arial;\"><span style=\"font-style: normal;\"><a href=\"https:\/\/www.daelimtransformer.com\/de\/csa-c802:-minimum-efficiency-values-for-power-transformers.html\"><span style=\"color: #c0392b;\">CSA Std<\/span><\/a><\/span><\/span><\/span><\/span><\/strong><\/p>\n<h3 style=\"margin-top: 17px; margin-bottom: 17px; text-align: justify;\"><span class=\"ez-toc-section\" id=\"What_are_the_Major_changes_and_revisions_for_this_type_of_Standard-2\"><\/span><span style=\"font-size: 14pt;\"><span style=\"line-height: 172%;\"><span style=\"font-family: Calibri;\"><b><span style=\"font-size: 14.0000pt;\"><span style=\"font-family: Calibri;\"><a id=\"4.1\" name=\"4.1\"><\/a>Was sind die wesentlichen \u00c4nderungen und \u00dcberarbeitungen f\u00fcr diesen Standardtyp?<\/span><\/span><\/b><\/span><\/span><\/span><span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Wesentliche \u00c4nderungen aus vorherigen Ausgaben wurden jetzt in diese aktualisierte Version des Standards integriert, einschlie\u00dflich Folgendem:<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">a) Referenzb\u00fccher und Definitionen werden regelm\u00e4\u00dfig aktualisiert, um neue Daten und neue oder ge\u00e4nderte Definitionen einzubeziehen.<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">b) Das Kaltstartverfahren und Hintergrundmaterial sind nun enthalten.\u00a0<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">c) Eine Isolierfl\u00fcssigkeit mit einem Schmelzpunkt von \u00fcber 300 Grad Celsius wurde ebenfalls eingef\u00fchrt.\u00a0<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">d) Die maximal zul\u00e4ssigen Temperaturen wurden aufgrund hei\u00dfer Regionen angepasst.<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">e) Neue Standards f\u00fcr die Stabilisierung von Wicklungen wurden gr\u00fcndlich umgesetzt.<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">f) Zus\u00e4tzliche Bestimmungen f\u00fcr Dichtungsmaterialien wurden hinzugef\u00fcgt.\u00a0<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">g) Als Ergebnis der steigenden Nachfrage wurden auch neue Spezifikationen f\u00fcr Schaltschilder festgelegt.<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">h) Folgende Tests wurden umfassend aktualisiert:<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<ul>\n<li class=\"p\" style=\"margin-bottom: 13px; text-align: left;\" value=\"50\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">induzierter Potential\u00a0<\/span><\/span><\/span><\/span><\/span><\/span><\/li>\n<li class=\"p\" style=\"margin-bottom: 13px; text-align: left;\" value=\"50\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Blitzimpuls\u00a0<\/span><\/span><\/span><\/span><\/span><\/span><\/li>\n<li class=\"p\" style=\"margin-bottom: 13px; text-align: left;\" value=\"50\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Schaltimpuls\u00a0<\/span><\/span><\/span><\/span><\/span><\/span><\/li>\n<li class=\"p\" style=\"margin-bottom: 13px; text-align: left;\" value=\"50\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Verlust und Impedanz\u00a0<\/span><\/span><\/span><\/span><\/span><\/span><\/li>\n<li class=\"p\" style=\"margin-bottom: 13px; text-align: left;\" value=\"50\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Tankdruck\u00a0<\/span><\/span><\/span><\/span><\/span><\/span><\/li>\n<li class=\"p\" style=\"margin-bottom: 13px; text-align: left;\" value=\"50\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Gasansammlung\u00a0<\/span><\/span><\/span><\/span><\/span><\/span><\/li>\n<\/ul>\n<p class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">i) Es gibt jetzt eine neue Bestimmung bez\u00fcglich HVDC-Umrichtertransformatoren.<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">j) Hinzuf\u00fcgung einer neuen Bestimmung zur Regelung von hochtemperaturisolierten Transformatoren.\u00a0<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">k) Vorschrift f\u00fcr Toleranz bei Lastverlusten.<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">l) Eine Zusammenfassungstabelle der inkludierten Tests.<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\">\u00a0<b><span style=\"font-size: 16.0000pt;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"color: #00b050;\"><span style=\"font-weight: bold;\"><span style=\"font-style: normal;\"><span style=\"font-family: Arial, Helvetica, sans-serif;\">Jetzt kostenlos ausprobieren: <\/span><\/span><\/span><\/span><\/span><\/span><\/b><a href=\"https:\/\/www.daelimtransformer.com\/de\/3-phase-pad-mounted-transformer.html\"><b><u><span class=\"15\" style=\"font-size: 16.0000pt;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"color: #ff0000;\"><span style=\"font-weight: bold;\"><span style=\"text-decoration: underline;\"><span style=\"text-underline: single;\"><span style=\"font-style: normal;\"><span style=\"font-family: Arial, Helvetica, sans-serif;\">Dreiphasen-Sockelmontierter Transformator<\/span><\/span><\/span><\/span><\/span><\/span><\/span><\/span><\/u><\/b><\/a><\/span><\/span><\/p>\n<h2 style=\"margin-bottom: 13px; text-align: left;\"><span class=\"ez-toc-section\" id=\"What_Are_The_Preparation_Of_Specifications_For_Single-Phase_Transformers_And_3-Phase_Transformers\"><\/span><span style=\"font-size: 18pt;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"font-weight: bold;\"><b><span style=\"font-size: 17.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-weight: bold;\"><span style=\"font-style: normal;\"><a id=\"5\" name=\"5\"><\/a>Was sind die Vorbereitung von Spezifikationen f\u00fcr einphasige Transformatoren und dreiphasige Transformatoren?<\/span><\/span><\/span><\/span><\/span><\/b><\/span><\/span><\/span><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><img decoding=\"async\" style=\"width: 650px; height: 433px;\" title=\"Einphasen-3-Phasen-Transformator\" src=\"\/media\/115\/single-phase-3-phase-transformer.webp\" alt=\"Einphasen-3-Phasen-Transformator\" \/><br \/>\n<span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Einer der ersten Schritte zur Sicherstellung der langfristigen Zuverl\u00e4ssigkeit von <\/span><\/span><\/span><\/span><strong><a href=\"https:\/\/www.daelimtransformer.com\/de\/pole-mounted-single-phase-transformer.html\"><u><span class=\"15\" style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0000ff;\"><span style=\"text-decoration: underline;\"><span style=\"text-underline: single;\"><span style=\"font-style: normal;\">einphasigen Transformatoren.<\/span><\/span><\/span><\/span><\/span><\/span><\/u><\/a><\/strong><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">\u00a0und 3-Phasen-Transformator besteht darin, detaillierte Spezifikationen zu erstellen.\u00a0<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Sofern sie gem\u00e4\u00df dem Handbuch korrekt verwendet werden und in gutem Zustand gehalten werden, um zu verhindern, dass die Isolierung zu schnell altert, sind Transformatoren zuverl\u00e4ssig und bieten einen st\u00f6rungsfreien Betrieb.<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Dies sind die Kriterien, nach denen die Bewertung erheblich bestimmt wird, gem\u00e4\u00df CSA-C88-M90. Sie entspricht der MV-nominalen Last zusammen mit der Spannung, dem Strom und der Frequenz des Herstellers.\u00a0<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Im Kontext dieser Norm wird sie daher als Bewertung zu Testzwecken verstanden, die die maximale Leistung definiert, die immer unter den angegebenen Testbedingungen aus dem Ger\u00e4t entnommen werden kann.<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><b><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-weight: bold;\"><span style=\"font-style: normal;\">NORMEN<\/span><\/span><\/span><\/span><\/span><\/b><\/span><\/span><\/p>\n<p class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Es ist wichtig zu beachten, dass Normen wie CSA-C88-M90 leicht unterschiedliche Definitionen und Anforderungen haben.\u00a0<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<ul>\n<li class=\"p\" style=\"margin-bottom: 13px; text-align: left;\" value=\"50\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">betriebliche Standardverfahren<\/span><\/span><\/span><\/span><\/span><\/span><\/li>\n<li class=\"p\" style=\"margin-bottom: 13px; text-align: left;\" value=\"50\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Nennleistung<\/span><\/span><\/span><\/span><\/span><\/span><\/li>\n<li class=\"p\" style=\"margin-bottom: 13px; text-align: left;\" value=\"50\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Zustand bei \u00fcberm\u00e4\u00dfiger Spannung<\/span><\/span><\/span><\/span><\/span><\/span><\/li>\n<li class=\"p\" style=\"margin-bottom: 13px; text-align: left;\" value=\"50\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">hohe Tragf\u00e4higkeit bei gefrierenden Temperaturen<\/span><\/span><\/span><\/span><\/span><\/span><\/li>\n<li class=\"p\" style=\"margin-bottom: 13px; text-align: left;\" value=\"50\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Vorschl\u00e4ge f\u00fcr Impedanzen<\/span><\/span><\/span><\/span><\/span><\/span><\/li>\n<li class=\"p\" style=\"margin-bottom: 13px; text-align: left;\" value=\"50\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">der Bewertungsprozess und Skalen<\/span><\/span><\/span><\/span><\/span><\/span><\/li>\n<li class=\"p\" style=\"margin-bottom: 13px; text-align: left;\" value=\"50\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Durchmesserdimensionen und Isolierung<\/span><\/span><\/span><\/span><\/span><\/span><\/li>\n<li class=\"p\" style=\"margin-bottom: 13px; text-align: left;\" value=\"50\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Anstieg der \u00d6stemperatur.<\/span><\/span><\/span><\/span><\/span><\/span><\/li>\n<li class=\"p\" style=\"margin-bottom: 13px; text-align: left;\" value=\"50\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Zapfspektrum<\/span><\/span><\/span><\/span><\/span><\/span><\/li>\n<li class=\"p\" style=\"margin-bottom: 13px; text-align: left;\" value=\"50\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Gr\u00f6\u00dfe des Magnetisierungsstroms, Verluste und Impedanz<\/span><\/span><\/span><\/span><\/span><\/span><\/li>\n<\/ul>\n<p class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Wie bereits erw\u00e4hnt, wurde die Ver\u00f6ffentlichung von CSA C88-M90 im Jahr 1990 2009 erneut best\u00e4tigt, hat jedoch keine Standards festgelegt.<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">In den meisten F\u00e4llen unterliegen IEEE- und IEC-Standards alle zehn Jahre einer umfassenden \u00dcberarbeitung oder Aktualisierung. Die Benutzer sollten die Spezifikationen ihrer Einheit f\u00fcr die Transformatoren an die Anforderungen von CSA-C88-M90 anpassen.<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p style=\"margin-top: 7px; margin-bottom: 7px; text-align: justify;\"><span style=\"font-size: 10.5pt;\"><span style=\"vertical-align: baseline;\"><span style=\"font-family: Calibri;\"><b><span style=\"font-size: 16.0000pt;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"color: #00b050;\"><span style=\"font-weight: bold;\"><span style=\"font-style: normal;\"><span style=\"font-family: Arial, Helvetica, sans-serif;\">Erfahren Sie mehr \u00fcber<\/span><\/span><\/span><\/span><\/span><\/span><\/b><b>\u00a0<\/b><a href=\"https:\/\/www.daelimtransformer.com\/de\/ieee-c57-standard.html\"><b><u><span class=\"15\" style=\"font-size: 16.0000pt;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"color: #ff0000;\"><span style=\"font-weight: bold;\"><span style=\"text-decoration: underline;\"><span style=\"text-underline: single;\"><span style=\"font-style: normal;\"><span style=\"font-family: Arial, Helvetica, sans-serif;\">IEEE-Standard<\/span><\/span><\/span><\/span><\/span><\/span><\/span><\/span><\/u><\/b><\/a><\/span><\/span><\/span><\/p>\n<h2 style=\"margin-bottom: 13px; text-align: left;\"><span class=\"ez-toc-section\" id=\"What_are_the_System_Requirements_for_Single-Phase_and_Three-Phase_Transformers\"><\/span><span style=\"font-size: 18pt;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"font-weight: bold;\"><b><span style=\"font-size: 17.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-weight: bold;\"><span style=\"font-style: normal;\"><a id=\"6\" name=\"6\"><\/a>Was sind die Systemanforderungen f\u00fcr einphasige und dreiphasige Transformatoren?<\/span><\/span><\/span><\/span><\/span><\/b><\/span><\/span><\/span><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Ob ein einphasiger oder dreiphasiger Transformator notwendig ist, h\u00e4ngt weitgehend von Faktoren wie der Gr\u00f6\u00dfe und den Gewichtsbeschr\u00e4nkungen des Standorts, den Kosten und der Verf\u00fcgbarkeit von Ersatzteilen sowie dem Bedarf an zuverl\u00e4ssigem Betrieb ab.<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<h3 style=\"margin-top: 17px; margin-bottom: 17px; text-align: justify;\"><span class=\"ez-toc-section\" id=\"Transportation\"><\/span><span style=\"font-size: 14pt;\"><span style=\"line-height: 172%;\"><span style=\"font-family: Calibri;\"><b><span style=\"font-size: 14.0000pt;\"><span style=\"font-family: Calibri;\"><a id=\"6.1\" name=\"6.1\"><\/a>Transport<\/span><\/span><\/b><\/span><\/span><\/span><span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Es ist m\u00f6glich, dass hydraulische Stationen aufgrund logistischer und Einrichtungskomplikationen nur einphasige Transformatoren verwenden k\u00f6nnen. Die meisten Unterstationen verwenden dreiphasige Transformatoren, da sie bis 500 am kosteneffektivsten sind.<\/span><\/span><\/span><\/span><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\"><span style=\"font-family: Arial, Helvetica, sans-serif;\">k<\/span><\/span><\/span><\/span><\/span><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">V verarbeiten.<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<h3 style=\"margin-top: 17px; margin-bottom: 17px; text-align: justify;\"><span class=\"ez-toc-section\" id=\"Winding_Connections\"><\/span><span style=\"font-size: 14pt;\"><span style=\"line-height: 172%;\"><span style=\"font-family: Calibri;\"><b><span style=\"font-size: 14.0000pt;\"><span style=\"font-family: Calibri;\"><a id=\"6.2\" name=\"6.2\"><\/a>Wickelverbindungen<\/span><\/span><\/b><\/span><\/span><\/span><span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Die Wicklungen in einem dreiphasigen Transformator k\u00f6nnen im Allgemeinen in einem Stern-, Delta- oder Zickzack-Muster verbunden werden. Transformatoren, die auf einer einzigen Phase arbeiten, haben ihre Verbindungen au\u00dferhalb der Lagertanks.\u00a0<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<h3 style=\"margin-top: 17px; margin-bottom: 17px; text-align: justify;\"><span class=\"ez-toc-section\" id=\"Vector_Group\"><\/span><span style=\"font-size: 14pt;\"><span style=\"line-height: 172%;\"><span style=\"font-family: Calibri;\"><b><span style=\"font-size: 14.0000pt;\"><span style=\"font-family: Calibri;\"><a id=\"6.3\" name=\"6.3\"><\/a>Vektorguppe<\/span><\/span><\/b><\/span><\/span><\/span><span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Der CSA-C88-M90 Standard der Vektorgroup definiert den Winkelausdruck als die Zeitverz\u00f6gerung zwischen der Linien-neutralen Spannung am Hochspannungsterminal (H1) und der am Niederspannungsterminal.<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Die Winkelausdr\u00fccke der meisten handels\u00fcblichen dreiphasigen Transformatoren sind entweder 0 (Uhrensystem) oder 30 (Grad) (Phasenausgleich).<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<h3 style=\"margin-top: 17px; margin-bottom: 17px; text-align: justify;\"><span class=\"ez-toc-section\" id=\"Levels_Of_Insulation\"><\/span><span style=\"font-size: 14pt;\"><span style=\"line-height: 172%;\"><span style=\"font-family: Calibri;\"><b><span style=\"font-size: 14.0000pt;\"><span style=\"font-family: Calibri;\"><a id=\"6.4\" name=\"6.4\"><\/a>Isolationsniveaus<\/span><\/span><\/b><\/span><\/span><\/span><span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Laut CSA-C88-M90 ist der akzeptable gr\u00f6\u00dfte Spannungsspitzenwert das Blitzimpulsniveau.<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Die systemweite Isolationskoordination ist entscheidend f\u00fcr eine optimale Isolationsleistung. Die Standards legen erhebliche Betonung auf das Vorhandensein verschiedener Isolationsniveaus bei gleichzeitiger Beibehaltung der Systemspannung (BILs).<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<h3 style=\"margin-top: 17px; margin-bottom: 17px; text-align: justify;\"><span class=\"ez-toc-section\" id=\"Terminals\"><\/span><span style=\"font-size: 14pt;\"><span style=\"line-height: 172%;\"><span style=\"font-family: Calibri;\"><b><span style=\"font-size: 14.0000pt;\"><span style=\"font-family: Calibri;\"><a id=\"6.5\" name=\"6.5\"><\/a>Anschl\u00fcsse<\/span><\/span><\/b><\/span><\/span><\/span><span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Ein Terminal, wie von CSA-C88-M90 festgelegt, ist ein Ger\u00e4t, das eine interne Wicklung mit einem externen Leiter verbindet.<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Die elektrischen Eigenschaften und physischen Merkmale des Terminals sollten immer in den vom Benutzer bereitgestellten Spezifikationen detailliert beschrieben werden.<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<ul>\n<li class=\"p\" style=\"margin-bottom: 13px; text-align: left;\" value=\"50\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Isolierstoff\u00a0<\/span><\/span><\/span><\/span><\/span><\/span><\/li>\n<li class=\"p\" style=\"margin-bottom: 13px; text-align: left;\" value=\"50\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Grad der Isolierung f\u00fcr Leitung und Neutralleiter.<\/span><\/span><\/span><\/span><\/span><\/span><\/li>\n<li class=\"p\" style=\"margin-bottom: 13px; text-align: left;\" value=\"50\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">\u00dcberm\u00e4\u00dfige Spannung<\/span><\/span><\/span><\/span><\/span><\/span><\/li>\n<li class=\"p\" style=\"margin-bottom: 13px; text-align: left;\" value=\"50\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\"><span style=\"font-family: Arial, Helvetica, sans-serif;\">E<\/span><\/span><\/span><\/span><\/span><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">\u00dcberm\u00e4\u00dfige Lasten<\/span><\/span><\/span><\/span><\/span><\/span><\/li>\n<li class=\"p\" style=\"margin-bottom: 13px; text-align: left;\" value=\"50\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Terminaltyp<\/span><\/span><\/span><\/span><\/span><\/span><\/li>\n<li class=\"p\" style=\"margin-bottom: 13px; text-align: left;\" value=\"50\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">\u00d6lwartungsmechanismus<\/span><\/span><\/span><\/span><\/span><\/span><\/li>\n<li class=\"p\" style=\"margin-bottom: 13px; text-align: left;\" value=\"50\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">CTs und deren Merkmale, die die L\u00e4nge des Erdschutzes der Dichtungen berechnen k\u00f6nnen.<\/span><\/span><\/span><\/span><\/span><\/span><\/li>\n<li class=\"p\" style=\"margin-bottom: 13px; text-align: left;\" value=\"50\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Ein Deckel, der horizontal platziert oder aufgesetzt ist.<\/span><\/span><\/span><\/span><\/span><\/span><\/li>\n<li class=\"p\" style=\"margin-bottom: 13px; text-align: left;\" value=\"50\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Standorte<\/span><\/span><\/span><\/span><\/span><\/span><\/li>\n<li class=\"p\" style=\"margin-bottom: 13px; text-align: left;\" value=\"50\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Anordnung und Identifizierung der Terminals<\/span><\/span><\/span><\/span><\/span><\/span><\/li>\n<li class=\"p\" style=\"margin-bottom: 13px; text-align: left;\" value=\"50\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">10 Anforderungen f\u00fcr die Einhaltung von CSA\/EEMAC<\/span><\/span><\/span><\/span><\/span><\/span><\/li>\n<\/ul>\n<p style=\"margin-top: 7px; margin-bottom: 7px; text-align: justify;\"><span style=\"font-size: 10.5pt;\"><span style=\"vertical-align: baseline;\"><span style=\"font-family: Calibri;\"><b><span style=\"font-size: 16.0000pt;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"color: #00b050;\"><span style=\"font-weight: bold;\"><span style=\"font-style: normal;\"><span style=\"font-family: Arial, Helvetica, sans-serif;\">Erfahren Sie mehr: <\/span><\/span><\/span><\/span><\/span><\/span><\/b><a href=\"https:\/\/www.daelimtransformer.com\/de\/single-phase-pad-mounted-transformer.html\"><b><u><span class=\"15\" style=\"font-size: 16.0000pt;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"color: #ff0000;\"><span style=\"font-weight: bold;\"><span style=\"text-decoration: underline;\"><span style=\"text-underline: single;\"><span style=\"font-style: normal;\"><span style=\"font-family: Arial, Helvetica, sans-serif;\">Einphasen-Bodenmontierter Transformator<\/span><\/span><\/span><\/span><\/span><\/span><\/span><\/span><\/u><\/b><\/a><\/span><\/span><\/span><\/p>\n<h2 style=\"margin-bottom: 13px; text-align: left;\"><\/h2>\n<h2 style=\"margin-bottom: 13px; text-align: left;\"><span class=\"ez-toc-section\" id=\"What_Are_The_Special_Requirements_For_Power_Transformers_and_Reactors_Of_CSA_C88\"><\/span><span style=\"font-size: 18pt;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"font-weight: bold;\"><b><span style=\"font-size: 17.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-weight: bold;\"><span style=\"font-style: normal;\"><a id=\"7\" name=\"7\"><\/a>Was sind die besonderen Anforderungen f\u00fcr Leistungs-transformatoren und Reaktoren? <\/span><\/span><\/span><\/span><\/span><\/b><b><span style=\"font-size: 17.0000pt;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"color: #0e101a;\"><span style=\"font-weight: bold;\"><span style=\"font-style: normal;\"><span style=\"font-family: Arial, Helvetica, sans-serif;\">Von CSA C88<\/span><\/span><\/span><\/span><\/span><\/span><\/b><b><span style=\"font-size: 17.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-weight: bold;\"><span style=\"font-style: normal;\">?<\/span><\/span><\/span><\/span><\/span><\/b><\/span><\/span><\/span><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Die Spezifikationen sollten Informationen zu verschiedenen nicht-standardisierten Anforderungen zus\u00e4tzlich zu den typischen Transformatorrichtlinien enthalten.<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Einige davon sind MV.A, Volt, Isolationsniveaus, Widerstand, Verlustbewertungswerte und Abgriffsinformationen.<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Hier sind einige der besonderen Anforderungen f\u00fcr Leistungs-transformatoren und Reaktoren:<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<ul>\n<li class=\"p\" style=\"margin-bottom: 13px; text-align: left;\" value=\"50\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Eine Erh\u00f6hung von MV in einer Weise anzugeben, die den IEEE-Standards von den s\u00fcdlichen Vereinigten Staaten entspricht, wird Ihnen helfen, die kosteng\u00fcnstigsten Transformatoren zu erhalten.<\/span><\/span><\/span><\/span><\/span><\/span><\/li>\n<li class=\"p\" style=\"margin-bottom: 13px; text-align: left;\" value=\"50\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Eine Bewertung in unterk\u00fchlten Bedingungen ist nicht erforderlich.<\/span><\/span><\/span><\/span><\/span><\/span><\/li>\n<li class=\"p\" style=\"margin-bottom: 13px; text-align: left;\" value=\"50\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Laut den CSA- und IEEE-Vorschriften ist eine \u00dcberspannung von 110% im Leerlauf und 105% unter Last inakzeptabel.<\/span><\/span><\/span><\/span><\/span><\/span><\/li>\n<li class=\"p\" style=\"margin-bottom: 13px; text-align: left;\" value=\"50\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Die empfohlene Vorfehler-Spannung gem\u00e4\u00df CSA-C88-M90 betr\u00e4gt 1,1 p.u. Benutzer sollten keine weiteren Informationen zu dieser Bedingung bereitstellen, als die Software erforderlich macht.<\/span><\/span><\/span><\/span><\/span><\/span><\/li>\n<li class=\"p\" style=\"margin-bottom: 13px; text-align: left;\" value=\"50\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Lastabh\u00e4ngige Abzapfstellen verwenden typischerweise hochviskose Schmierstoffe wie Voltesso 35, die es den Ger\u00e4ten erm\u00f6glichen, bei Temperaturen von bis zu -25 \u00b0C zu funktionieren.<\/span><\/span><\/span><\/span><\/span><\/span><\/li>\n<li class=\"p\" style=\"margin-bottom: 13px; text-align: left;\" value=\"50\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Geben Sie eine H\u00f6he \u00fcber dem Meeresspiegel an, wenn die Transformatoren allgemein in H\u00f6henlagen von mehr als 1.000 Metern verwendet werden.<\/span><\/span><\/span><\/span><\/span><\/span><\/li>\n<li class=\"p\" style=\"margin-bottom: 13px; text-align: left;\" value=\"50\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Wenn die Transformatoren normalerweise in schmutzigen Umgebungen eingesetzt werden, m\u00fcssen die Kriechwege der Isolatoren ebenfalls bestimmt werden.<\/span><\/span><\/span><\/span><\/span><\/span><\/li>\n<li class=\"p\" style=\"margin-bottom: 13px; text-align: left;\" value=\"50\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Wenn ein Direktersatztransformator notwendig ist, muss das Volumen des Lecks minimal sein.<\/span><\/span><\/span><\/span><\/span><\/span><\/li>\n<li class=\"p\" style=\"margin-bottom: 13px; text-align: left;\" value=\"50\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Die Anforderungen k\u00f6nnten ein bestimmtes \u00d6lkonservierungssystem verlangen, wie z. B. einen freiatmenden Konservator, einen Luftpolsterkonservator oder ein mit Stickstoff druckbetriebenes System.<\/span><\/span><\/span><\/span><\/span><\/span><\/li>\n<li class=\"p\" style=\"margin-bottom: 13px; text-align: left;\" value=\"50\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Die Verwendung von FR3-\u00d6l sollte in den technischen Anforderungen f\u00fcr Abzapfer, Isolatoren und andere Komponenten von Transformatoren festgelegt werden.<\/span><\/span><\/span><\/span><\/span><\/span><\/li>\n<li class=\"p\" style=\"margin-bottom: 13px; text-align: left;\" value=\"50\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Ein variabler Fluss-Abzapfautotransformator hat eine terti\u00e4re Spannungsabgabe, die zwischen den Abzapfpunkten wechselt.<\/span><\/span><\/span><\/span><\/span><\/span><\/li>\n<\/ul>\n<p style=\"margin-top: 7px; margin-bottom: 7px; text-align: justify;\"><span style=\"font-size: 10.5pt;\"><span style=\"vertical-align: baseline;\"><span style=\"font-family: Calibri;\"><b><span style=\"font-size: 16.0000pt;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"color: #00b050;\"><span style=\"font-weight: bold;\"><span style=\"font-style: normal;\"><span style=\"font-family: Arial, Helvetica, sans-serif;\">Weiterlesen: <\/span><\/span><\/span><\/span><\/span><\/span><\/b><a href=\"https:\/\/www.daelimtransformer.com\/de\/basic-guide-to-high-voltage-power-transformer.html\"><b><u><span class=\"15\" style=\"font-size: 16.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #ff0000;\"><span style=\"font-weight: bold;\"><span style=\"text-decoration: underline;\"><span style=\"text-underline: single;\"><span style=\"font-style: normal;\">Grundlegender Leitfaden f\u00fcr Hochspannungstransformatoren<\/span><\/span><\/span><\/span><\/span><\/span><\/span><\/u><\/b><\/a><\/span><\/span><\/span><\/p>\n<h2 style=\"margin-bottom: 13px; text-align: left;\"><span class=\"ez-toc-section\" id=\"What_Are_The_Rating_Plate_For_Power_Transformers_and_Reactors\"><\/span><span style=\"font-size: 18pt;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"font-weight: bold;\"><b><span style=\"font-size: 17.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-weight: bold;\"><span style=\"font-style: normal;\"><a id=\"8\" name=\"8\"><\/a>Was sind die Typenschildanforderungen f\u00fcr Leistungstransformatoren und Reaktoren?<\/span><\/span><\/span><\/span><\/span><\/b><\/span><\/span><\/span><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><img decoding=\"async\" style=\"width: 650px; height: 433px;\" title=\"csa Leistungstransformator\" src=\"\/media\/115\/csa-power-transformer.webp\" alt=\"csa Leistungstransformator\" \/><br \/>\n<span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Als Benutzer sollten Sie das Datenblatt als das wichtigste und am leichtesten verf\u00fcgbare Dokument des Transformators betrachten.\u00a0<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Dieser Begriff wird oft als Namensschild bezeichnet in <\/span><\/span><\/span><\/span><a href=\"https:\/\/standards.ieee.org\/ieee\/C57.12.10\/4680\/\" target=\"_blank\" rel=\"noopener\"><u><span class=\"15\" style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #4a6ee0;\"><span style=\"text-decoration: underline;\"><span style=\"text-underline: single;\"><span style=\"font-style: normal;\">C57.12.10-2010<\/span><\/span><\/span><\/span><\/span><\/span><\/u><\/a><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">.<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Die Lesbarkeit des Datenblatts nimmt in der Regel nach einigen Jahren Gebrauch ab. Gravierungen und Stempelungen oder eine andere dauerhafte Technik zum Eintragen von Datenspeichern sind gem\u00e4\u00df CSA-C88-M90 erforderlich.<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<ul>\n<li class=\"p\" style=\"margin-bottom: 13px; text-align: left;\" value=\"50\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Ein Nameplate des Abzapfers muss sicher im LTC-Abteil des Transformators angebracht werden, um den Anforderungen von C57.131 zu entsprechen.<\/span><\/span><\/span><\/span><\/span><\/span><\/li>\n<li class=\"p\" style=\"margin-bottom: 13px; text-align: left;\" value=\"50\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Zeitlich gekennzeichnetes Phasendiagramm eines polyphasen Transformators, dessen Merkmale entscheidend f\u00fcr ein Unternehmen von ausreichender Gr\u00f6\u00dfe sind.<\/span><\/span><\/span><\/span><\/span><\/span><\/li>\n<li class=\"p\" style=\"margin-bottom: 13px; text-align: left;\" value=\"50\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Es ist wichtig zu \u00fcberlegen, wie gro\u00df die Buchstaben und Zahlen sind (C57.12.00-2010 spezifiziert mindestens 4 mm).<\/span><\/span><\/span><\/span><\/span><\/span><\/li>\n<li class=\"p\" style=\"margin-bottom: 13px; text-align: left;\" value=\"50\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Zuk\u00fcnftige Pl\u00e4ne zur Installation von Druckluft-K\u00fchlsystemen.\u00a0<\/span><\/span><\/span><\/span><\/span><\/span><\/li>\n<li class=\"p\" style=\"margin-bottom: 13px; text-align: left;\" value=\"50\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">F\u00e4higkeit, sich an einen schnellen Wechsel anzupassen und ihn zu absorbieren.\u00a0<\/span><\/span><\/span><\/span><\/span><\/span><\/li>\n<li class=\"p\" style=\"margin-bottom: 13px; text-align: left;\" value=\"50\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Das Namensschild muss alle nichtlinearen Komponenten auflisten, wie z. B. Kondensatoren, Widerst\u00e4nde usw., die Teil der Wicklungsanordnung oder eines Abzapfers sind.<\/span><\/span><\/span><\/span><\/span><\/span><\/li>\n<\/ul>\n<h2 style=\"margin-bottom: 13px; text-align: left;\"><span class=\"ez-toc-section\" id=\"What_does_CSAs_Standards_Mean_to_Globalization\"><\/span><span style=\"font-size: 18pt;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"font-weight: bold;\"><b><span style=\"font-size: 17.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-weight: bold;\"><span style=\"font-style: normal;\"><a id=\"9\" name=\"9\"><\/a>Was bedeutet der CSA-Standard f\u00fcr die Globalisierung?<\/span><\/span><\/span><\/span><\/span><\/b><\/span><\/span><\/span><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Um erschwingliche, qualitativ hochwertige Transformatoren auszuw\u00e4hlen, m\u00fcssen die Verbraucher zun\u00e4chst die bereitgestellten Spezifikationen konsultieren.\u00a0<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Bevor der Globalisierungsprozess begann, lieferten inl\u00e4ndische Produzenten typischerweise Transformatoren an Verbraucher in ihren Heimatl\u00e4ndern.<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Nach Jahren der Zusammenarbeit hatten die lokalen Produzenten ein umfassendes Verst\u00e4ndnis daf\u00fcr, was f\u00fcr die Gemeinschaft notwendig war.<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">\u00a0Es ist jetzt unerl\u00e4sslich, dass die Anforderungen f\u00fcr das System seine beabsichtigte Funktion genau widerspiegeln.<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Im Interesse des Fortschritts muss dieses Muster ge\u00e4ndert werden.\u00a0<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Um wirtschaftliche Vorteile zu maximieren, sollten Standardanwender einschr\u00e4nkende Klauseln von Normen \u00fcberpr\u00fcfen, bevor sie diese in Spezifikationen zitieren.<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Globale Standards k\u00f6nnen nur von einem einheitlichen internationalen Gremium entwickelt werden.\u00a0<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Daher wird die Kommunikation zwischen Verbrauchern und Produzenten erheblich vereinfacht, wenn es einheitliche Standards gibt, was allen zugutekommt.<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Insbesondere f\u00fcr gro\u00dfe Energieanlagen wie Leistungstransformatoren sind CSA-Standards f\u00fcr K\u00e4ufer von gro\u00dfer Bedeutung. Mit diesem Standard kann sichergestellt werden, dass die <\/span><\/span><\/span><\/span><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\"><span style=\"font-family: Arial, Helvetica, sans-serif;\">Energie <\/span><\/span><\/span><\/span><\/span><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Transformatoren, die Sie kaufen, sicher und zuverl\u00e4ssig sind und die Qualit\u00e4t erheblich gew\u00e4hrleistet ist.<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><b><span style=\"font-size: 16.0000pt;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"color: #00b050;\"><span style=\"font-weight: bold;\"><span style=\"font-style: normal;\"><span style=\"font-family: Arial, Helvetica, sans-serif;\">Jetzt erhalten: <\/span><\/span><\/span><\/span><\/span><\/span><\/b><a href=\"https:\/\/www.daelimtransformer.com\/de\/test-of-power-transformer.html\"><b><u><span class=\"15\" style=\"font-size: 16.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #ff0000;\"><span style=\"font-weight: bold;\"><span style=\"text-decoration: underline;\"><span style=\"text-underline: single;\"><span style=\"font-style: normal;\">Wie testet man einen Leistungstransformator?<\/span><\/span><\/span><\/span><\/span><\/span><\/span><\/u><\/b><\/a><\/span><\/span><\/p>\n<h2 style=\"margin-bottom: 13px; text-align: left;\"><span class=\"ez-toc-section\" id=\"Ending_Thoughts\"><\/span><span style=\"font-size: 18pt;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"font-weight: bold;\"><b><span style=\"font-size: 17.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-weight: bold;\"><span style=\"font-style: normal;\"><a id=\"10\" name=\"10\"><\/a>Abschlie\u00dfende Gedanken\u00a0<\/span><\/span><\/span><\/span><\/span><\/b><\/span><\/span><\/span><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Wie Sie sehen k\u00f6nnen, k\u00f6nnen die Spezifikationen oft nicht allein aus Standards abgeleitet werden.<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Wenn Richtlinien genau befolgt werden, ist es m\u00f6glich, Transformatoren auszuw\u00e4hlen, die sowohl effektiv als auch wirtschaftlich sind.<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Dar\u00fcber hinaus k\u00f6nnen allgemein zuverl\u00e4ssigere Transformatoren mit regelm\u00e4\u00dfigen Aktualisierungen der Anforderungen, basierend auf den in einem Land geleisteten Arbeiten, hergestellt werden.<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p><iframe title=\"YouTube Video-Player\" src=\"https:\/\/www.youtube.com\/embed\/ltR1CIb1Xp8\" width=\"100%\" height=\"315\" frameborder=\"0\" allowfullscreen=\"allowfullscreen\"><\/iframe><\/p>\n<p class=\"p\" style=\"text-indent: 0.0000pt; text-align: left;\"><span style=\"font-size: 12pt; font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Letztendlich garantiert Daelim die Einhaltung aller<\/span><\/span><\/span><\/span>\u00a0<\/span><span style=\"color: #0e101a; font-family: Arial;\"><span style=\"font-size: 14.6667px;\">von der CSA geforderten<\/span><\/span><span style=\"font-family: Calibri;\"><span style=\"font-size: 12pt;\">\u00a0<\/span><\/span><span style=\"font-family: Calibri; font-size: 11pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">Standards. Die Leistungstransformatoren von Daelim besitzen cUL- und CSA-Zertifikate. Wenn Sie Transformatoren nach CSA-Standard ben\u00f6tigen, z\u00f6gern Sie nicht, <\/span><\/span><\/span><\/span><strong><a style=\"font-family: Calibri; font-size: 12pt;\" href=\"https:\/\/www.daelimtransformer.com\/de\/contact.html\"><u><span class=\"15\" style=\"font-size: 11.0000pt;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"color: #0000ff;\"><span style=\"text-decoration: underline;\"><span style=\"text-underline: single;\"><span style=\"font-style: normal;\"><span style=\"font-family: Arial, Helvetica, sans-serif;\">C<\/span><\/span><\/span><\/span><\/span><\/span><\/span><\/u><u><span class=\"15\" style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0000ff;\"><span style=\"text-decoration: underline;\"><span style=\"text-underline: single;\"><span style=\"font-style: normal;\">ontact The Daelim<\/span><\/span><\/span><\/span><\/span><\/span><\/u><\/a><\/strong><span style=\"font-family: Calibri; font-size: 11pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #0e101a;\"><span style=\"font-style: normal;\">\u00a0Team f\u00fcr Zeichnungen, technische Parameter und Angebote.<\/span><\/span><\/span><\/span><\/p>\n<p><!-- \u5de6\u53f3\u56fe\u6587--><\/p>\n<p><!-- \u8c46\u8150\u5757\u56fe\u6587\u4e0a\u4e0b--><\/p>\n<p><!--\u6587\u5b57\u6a21\u5757--><\/p>\n<p><!-- \u5de6\u53f3\u56fe\u6587--><\/p>\n<p><!--\u6587\u5b57\u6a21\u5757--><\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>CSA C88 is a comprehensive standard for power transformer and reactor bushings in Canada and across the globe. Daelim is a professional supplier of CSA standard transformers. Not only has CSA product certification but also cUL listed. It can provide CSA and cUL labeling services for your transformer. This standard is suitable for lightning impulse [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":7405,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[279],"tags":[],"class_list":["post-7404","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articles-news"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/posts\/7404","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/comments?post=7404"}],"version-history":[{"count":0,"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/posts\/7404\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/media\/7405"}],"wp:attachment":[{"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/media?parent=7404"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/categories?post=7404"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/tags?post=7404"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}