{"id":7449,"date":"2026-01-05T08:50:56","date_gmt":"2026-01-05T08:50:56","guid":{"rendered":"https:\/\/daelimtransformer.com\/?p=7449"},"modified":"2026-03-13T11:52:35","modified_gmt":"2026-03-13T11:52:35","slug":"comprehensive-guide-to-18mva-to-90mva-transformers","status":"publish","type":"post","link":"https:\/\/www.daelimtransformer.com\/de\/18mva-to-90mva-transformers.html","title":{"rendered":"Umfassender Leitfaden zu 18MVA bis 90MVA Transformatoren"},"content":{"rendered":"<div id=\"contentMain\" class=\"article-content\">\n<p><!-- \u5de6\u53f3\u56fe\u6587--><!--\u6587\u5b57\u6a21\u5757--><\/p>\n<p><!-- \u8c46\u8150\u5757\u56fe\u6587\u4e0a\u4e0b--><\/p>\n<p><!-- \u5de6\u53f3\u56fe\u6587--><\/p>\n<p><!--\u6587\u5b57\u6a21\u5757--><\/p>\n<div class=\"row\">\n<div class=\"col-lg-12\">\n<div class=\"d-flex align-items-center mb-3 mt-5\">\n<div class=\"d-inline-block w-100 mb-3 mr-auto ml-auto\">\n<p><!-- style=\"color:#003b92;\">.<\/h2>\n\n\n--><\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"row\">\n<div class=\"col-lg-12 article-content\">\n<p class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><a href=\"https:\/\/www.daelimtransformer.com\/de\/contact.html\"><img decoding=\"async\" style=\"width: 340px; height: 340px; float: right;\" title=\"Preis f\u00fcr 18mva -90 mva Transformator\" src=\"\/media\/115\/18-90-mva-transformer-price.jpg\" alt=\"Preis f\u00fcr 18mva -90 mva Transformator\" \/><\/a>Elektrische Leistungstransformatoren sind die h\u00e4ufigsten Arten von Ger\u00e4ten, die zur Stromversorgung verwendet werden, typischerweise mit Leistungseinstufungen von 18 MVA bis 90 MVA. Sie arbeiten bei Spannungen zwischen 44 kV und 230 kV und sind entweder in einer dreiphasigen oder einphasigen Konfiguration erh\u00e4ltlich. Diese Transformatoren k\u00f6nnen entweder mit lastabgreifendem oder abgeschaltetem Abgriffwechsel ausgestattet sein. Sie werden h\u00e4ufig in der Strom\u00fcbertragung und in Umspannwerken eingesetzt. Die Hauptmerkmale dieser Transformatoren umfassen hohe Kurzschlussfestigkeit, geringe Teilentladungsniveaus, minimales Ger\u00e4usch, niedrige Energieverluste und leisen Betrieb.<\/p>\n<p>Daelim ist ein professioneller Hersteller von Leistungstransformatoren mit \u00fcber 20 Jahren Erfahrung im amerikanischen Markt. Sie sind auf die Bereitstellung von Transformatoren mit Leistungseinstufungen von 18 bis 90 MVA spezialisiert. Die Transformatoren von Daelim verf\u00fcgen \u00fcber UL-, cUL-, CSA- und andere Zertifizierungen, die ihre hohe Qualit\u00e4t und die Einhaltung von Sicherheitsstandards gew\u00e4hrleisten. Ihr Engagement f\u00fcr zuverl\u00e4ssige und professionelle Dienstleistungen hat ihnen Anerkennung bei Kunden in den USA, Kanada und anderen L\u00e4ndern eingebracht.<\/p>\n<p>Jetzt werden wir \u00fcber Leistungstransformatoren sprechen, die eine Nennleistung von 18 MVA bis 90 MVA haben. Wir werden genau durchgehen, was sie sind und wie man sie nutzen kann.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"What_Is_The_Electrical_Design_For_18_MVA_To_90_MVA_Transformers\"><\/span>Was ist das elektrische Design f\u00fcr 18 MVA bis 90 MVA Transformatoren?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><img decoding=\"async\" style=\"width: 600px; height: 401px;\" title=\"18mva 66kv Transformator\" src=\"\/media\/115\/AS-66kv-18mva-transformer.webp\" alt=\"18mva 66kv Transformator\" \/><br \/>\nDie K\u00fchlmethoden, erh\u00f6hte Temperaturen, Installation und Erdungssysteme sind alles Faktoren, die immer ber\u00fccksichtigt werden sollten, wenn man den elektrischen Aspekt eines Transformators entwirft.<\/p>\n<p>K\u00fchlmethoden und Leistungsverarbeitung<\/p>\n<p>Wenn f\u00fcr einen Transformator nur eine Leistungsbewertung angegeben ist, wird auch angenommen, dass der Transformator eine nat\u00fcrliche \u00d6l-Luft-K\u00fchlung (ONAN oder OA) anwendet.<\/p>\n<p>Wenn es zwei Bewertungen gibt, ist entweder ONAF oder FA (zwei-stufige Zwangsluftk\u00fchlung) erforderlich.<\/p>\n<p>Erh\u00f6hte Temperatur<\/p>\n<p>Laut den Standards m\u00fcssen die folgenden Temperaturerh\u00f6hungen bei Transformatoren von 18 MVA bis 90 MVA haupts\u00e4chlich von leistungsbewerteten Einheiten eingehalten werden.<\/p>\n<ul>\n<li>40 \u00b0C maximale Temperatur<\/li>\n<li>30 \u00b0C durchschnittlich an 1 Tag<\/li>\n<li>20 \u00b0C durchschnittlich in 1 Jahr<\/li>\n<li>\u00a0\u201325 \u00b0C niedrigste Temperatur im Freien<\/li>\n<li>\u00a0\u20135 \u00b0C niedrigste Temperatur im Innenraum<\/li>\n<\/ul>\n<p>Installation<\/p>\n<p>Die maximale H\u00f6he, in der diese Transformatoren funktionieren k\u00f6nnen, betr\u00e4gt 1000 Meter. Wenn sich Ihr Standort in der Regel in einer h\u00f6heren Lage als 1.000 Meter befindet, m\u00fcssen Sie Ihren Transformator aufr\u00fcsten.<\/p>\n<p>Vektorgruppen<\/p>\n<p>Gro\u00dfe Leistungstransformer und Erzeugungstransformer wie 18 MVA bis 90 MVA verwenden h\u00e4ufig Yd-Verkabelungen. Der Schutz des Neutralleiters sinkt schnell nach 110 kV der Hochspannungswicklungen.<\/p>\n<p><a id=\"mdnTags1\" name=\"mdn1\" data-index=\"1\"><\/a><\/p>\n<p>Erfahren Sie mehr \u00fcber <a href=\"https:\/\/daelimbelefic.com\/transformer-designs\" target=\"_blank\" rel=\"noopener\">Transformator Design<\/a><\/p>\n<p><a id=\"mdnTags2\" class=\"mdnTags\" name=\"mdn2\" data-index=\"2\"><\/a><\/p>\n<h2><span class=\"ez-toc-section\" id=\"What_Is_The_Mechanical_Design_For_18_MVA_To_90_MVA_Transformers\"><\/span>Was ist das mechanische Design f\u00fcr 18 MVA bis 90 MVA Transformatoren?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Mechanische Konstruktions\u00fcberlegungen, wie das Tank- und \u00d6lkonservierungssystem des Transformators, sind entscheidend f\u00fcr den Herstellungsprozess.<\/p>\n<p>Tankdesign<\/p>\n<p>Ein konventioneller geschlossener Tank-Distributionstransformator, dieses Modell kann Leistungswerte von bis zu 18 MVA und 90 MVA mit einem Konservator bew\u00e4ltigen.<\/p>\n<p>Transformatoren\u00f6l ist immer im Versand und in der Verpackung enthalten. Das Austauschen von Isolierwaren kann auch von au\u00dfen an der Maschine erfolgen, ohne das \u00d6l aus dem beweglichen Teil abzulassen.<\/p>\n<p>Allgemeines mechanisches Design:<\/p>\n<ol>\n<li>Mechanisch gestalteter Eisenkern, elektrisch isolierter Stahlblech mit Kornorientierung<\/li>\n<li>Sowohl Kupferdraht als auch Kupferband k\u00f6nnen im Allgemeinen f\u00fcr Kupferwicklungen verwendet werden.<\/li>\n<li>Hat eine Kurzschlussfestigkeit von mindestens 2 Sekunden (IEC).<\/li>\n<li>Dieser Radiatorbeh\u00e4lter\/\u00d6lstorage Container ist aufgrund seiner robusten wellenf\u00f6rmigen Seiten perfekt.<\/li>\n<li>Transformative Unterr\u00e4der, die entweder flach oder geflanscht sind.<\/li>\n<li>Das Mineral\u00f6l, das den Standards der VDE und IEC entspricht, wird haupts\u00e4chlich als K\u00fchl- und Isolierfluid eingesetzt.<\/li>\n<li>Entwickelt f\u00fcr den Einsatz in der Natur oder anderen unkonventionellen Umgebungen, k\u00f6nnen diese Oberfl\u00e4chenbehandlungen den Witterungseinfl\u00fcssen standhalten.<\/li>\n<\/ol>\n<p><a id=\"mdnTags3\" name=\"mdn3\" data-index=\"3\"><\/a><\/p>\n<p>Sie k\u00f6nnten genie\u00dfen:\u00a0<a href=\"https:\/\/www.daelimtransformer.com\/de\/transformer-impedance.html\">Die Auswirkungen der Impedanz auf das Design von Transformatoren.<\/a><\/p>\n<p><a id=\"mdnTags4\" name=\"mdn4\" data-index=\"4\"><\/a><\/p>\n<h2><span class=\"ez-toc-section\" id=\"What_Is_The_Connection_Systems_For_18_MVA_To_90_MVA_Transformers\"><\/span><a id=\"3\" name=\"3\"><\/a>Was sind die Verbindungssysteme f\u00fcr 18 MVA bis 90 MVA Transformatoren?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><img decoding=\"async\" style=\"width: 345px; height: 496px; float: right;\" title=\"MVA Transformatoranschluss \" src=\"\/media\/115\/connection-mvatransformer.webp\" alt=\"MVA Transformatoranschluss \" \/>Um elektrische Energie in ein Magnetfeld umzuwandeln, sind die meisten Transformatoren mit Nennwerten von 18 MVA bis 90 MVA so konstruiert, dass ihre Hauptwicklungen mit der Eingangsspannungsquelle verbunden sind.<\/p>\n<p>Im Gegensatz dazu ist die sekund\u00e4re Wicklung daf\u00fcr verantwortlich, das wechselnde Magnetfeld in die erforderliche Menge elektrischer Energie umzuwandeln, um die Ausgangsspannung bereitzustellen.<\/p>\n<p>Konnektivit\u00e4tssystem<\/p>\n<p>Die externe Durchf\u00fchrungsisolierung ist die typischste Verbindung f\u00fcr Transformatoren mit 18 MVA bis 90 MVA.<\/p>\n<p>Die Transformatordurchf\u00fchrungen k\u00f6nnen generell vertikal, horizontal oder schr\u00e4g angeboten werden, abh\u00e4ngig von der Spannung, dem Strom, den Systembedingungen und den Transportanforderungen.<\/p>\n<p>Die DIN schreibt vor, dass \u00f6lgef\u00fcllte Durchf\u00fchrungen bis zu 110 kV sicher sind, auch wenn Kondensator-Durchf\u00fchrungen typischerweise bei h\u00f6heren Spannungen verwendet werden.<\/p>\n<p>Um Platz zu sparen oder eine bestimmte \u00c4sthetik zu wahren, ist es oft notwendig, Kabel direkt zum Transformator zu f\u00fchren.<\/p>\n<p>F\u00fcr Systeme mit Spannungen unter 30 Kilovolt sind luftgef\u00fcllte Kabelboxen akzeptabel.<\/p>\n<p>Wenn das \u00d6l die Geh\u00e4use f\u00fcllt, isoliert es sie effektiv von den h\u00f6heren Spannungen. Sie k\u00f6nnen sie \u00fcberall dort montieren, wo Sie es w\u00fcnschen, am Tank.<\/p>\n<p><a id=\"mdnTags5\" class=\"mdnTags\" name=\"mdn5\" data-index=\"5\"><\/a><\/p>\n<p>Mehr lesen \u00fcber <a href=\"https:\/\/www.daelimtransformer.com\/de\/transformer-connection.html\">Transformatorverbindung<\/a><\/p>\n<p><a id=\"mdnTags6\" class=\"mdnTags\" name=\"mdn6\" data-index=\"6\"><\/a><\/p>\n<h2><span class=\"ez-toc-section\" id=\"How_Do_You_Evaluate_the_Causes_For_Transformer_Loss_Between_18_MVA_and_90_MVA\"><\/span>Wie bewertet man die Ursachen f\u00fcr Transformatorenverluste zwischen 18 MVA und 90 MVA?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Steigende Strompreise bedeuten, dass Kunden darauf achten sollten, kein Geld f\u00fcr unn\u00f6tige Einheiten zu verschwenden.<\/p>\n<p>Verteilungs- und Leistungstransformatoren mit einer Nennleistung von 18 MVA bis 90 MVA, die h\u00e4ufig unter Last eingesetzt werden und st\u00e4ndig arbeiten m\u00fcssen, w\u00fcrden stark davon profitieren.<\/p>\n<p>In vielen F\u00e4llen k\u00f6nnen die Einsparungen bei den Energiekosten durch die Verwendung von verlustoptimierten Transformatoren die Anschaffungskosten der Ger\u00e4te in weniger als drei Jahren decken.<\/p>\n<p>Diese einfache Methode kann haupts\u00e4chlich verwendet werden, um die Preise verschiedener angegebener Transformatorverluste schnell zu vergleichen.<\/p>\n<ul>\n<li>Die Transformatoren werden im Allgemeinen st\u00e4ndig verwendet.<\/li>\n<li>Transformatoren arbeiten mit einer Teillast, aber diese Teillast ist immer vorhanden.<\/li>\n<li>Zus\u00e4tzliche Kosten und Inflation werden nicht ber\u00fccksichtigt.<\/li>\n<li>Die Nachfragegeb\u00fchren basieren normalerweise auf einer vollen Last.<\/li>\n<\/ul>\n<p>Niedrigverlusttransformatoren wie 18 MVA bis 90 MVA haben einen h\u00f6heren empfohlenen Verkaufspreis, da sie teurere Komponenten verwenden.<\/p>\n<p>Sie k\u00f6nnten genie\u00dfen: <a href=\"https:\/\/www.daelimtransformer.com\/de\/pad-mounted-transformer.html\">Bodenmontierter Transformator<\/a><\/p>\n<p><a id=\"mdnTags7\" class=\"mdnTags\" name=\"mdn7\" data-index=\"7\"><\/a><\/p>\n<h2><span class=\"ez-toc-section\" id=\"MVA_Power_and_Specifications_18MVA_to_90MVA_Transformers\"><\/span>MVA Leistung und Spezifikationen: 18MVA bis 90MVA Transformatoren<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Der 18 MVA bis 90 MVA Transformator von Daelim zeichnet sich durch innovative Qualit\u00e4t aus, die mit hochwertigen Materialien und Komponenten hergestellt wurde, um zuverl\u00e4ssige Qualit\u00e4t und eine lange Lebensdauer zu bieten.<\/p>\n<p>Dar\u00fcber hinaus werden die von Daelim hergestellten Leistungstransformatoren in China hochgradig zusammengesetzt und sind so gebaut, dass sie weltweit mit vollst\u00e4ndigem Vertrauen liefern.<\/p>\n<p>Sie haben 18 MVA bis 90 MVA Transformatoren, die speziell entwickelt wurden, um die Standards und Anforderungen zu erf\u00fcllen oder zu \u00fcbertreffen, die auf lokaler, regionaler, nationaler und internationaler Ebene gelten.<\/p>\n<p>Wenn Sie nach MVA-Transformatoren von h\u00f6chster Qualit\u00e4t suchen, ist Daelim das Unternehmen, dem Sie vertrauen sollten.<\/p>\n<p>Lassen Sie uns jeden einzelnen identifizieren und entdecken.<\/p>\n<p><a id=\"mdnTags8\" class=\"mdnTags\" name=\"mdn8\" data-index=\"8\"><\/a><\/p>\n<p>Lesen Sie meinen Artikel \u00fcber <a href=\"https:\/\/www.daelimtransformer.com\/de\/4mva-to-16mva-transformer.html\">Der ultimative Leitfaden f\u00fcr 4-16 MVA Transformatoren<\/a><\/p>\n<p><a id=\"mdnTags9\" name=\"mdn9\" data-index=\"9\"><\/a><\/p>\n<h2><span class=\"ez-toc-section\" id=\"How_Much_Power_And_Specification_Does_An_18_MVA_Transformer_Have\"><\/span><a id=\"6\" name=\"6\"><\/a>Wie viel Leistung und Spezifikation hat ein 18 MVA Transformator?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Der 18 MVA Leistungstransformator hat eine Kapazit\u00e4t von 18000 kVA. Dieser 18000 kVA Transformator mit Absenkung hat Bewertungen von 66\/13,8 kV.<\/p>\n<p>Der 18 MVA Niedrigverlusttransformator von Daelim ist eine neue Generation von Transformatoren, die im Wesentlichen intern mit innovativer Technik aus dem In- und Ausland entwickelt wurde.<\/p>\n<p>Der 18 MVA Transformator hat ein hohes Ma\u00df an Zuverl\u00e4ssigkeit, ausgezeichneten Schutz gegen pl\u00f6tzliche Kurzschl\u00fcsse und au\u00dfergew\u00f6hnlich niedrige Werte f\u00fcr lokale Entladungen, Energieverluste, L\u00e4rm und Ger\u00e4usch.<\/p>\n<ul>\n<li>Nennleistung: 18 MVA<\/li>\n<li>\u00c4quivalente KV: 18.000 KVA<\/li>\n<li>Frequenz: 50\/60Hz<\/li>\n<li>Phasierung: Drei<\/li>\n<li>K\u00fchltyp: ONAN\/ONAF<\/li>\n<li>Hauptspannung: 230 kV\/220 kV\/138 kV\/110 kV\/69 kV<\/li>\n<li>2. Spannung: 11 kV \/ 35 kV \/ 66 kV \/ 69 kV<\/li>\n<li>Vektorgruppe: YNd11<\/li>\n<li>Impedanz: 11-14%<\/li>\n<li>Abgriffwechsel: OLTC\/NLTC<\/li>\n<li>Abgriffsbereich: \u00b18*1.25%<\/li>\n<li>Zubeh\u00f6r: Standardkonfiguration<\/li>\n<li>Konstruktion: Kupfer\/Aluminium<\/li>\n<\/ul>\n<p><a id=\"mdnTags10\" class=\"mdnTags\" name=\"mdn10\" data-index=\"10\"><\/a><\/p>\n<p>Kostenlos erhalten:\u00a0<a href=\"https:\/\/www.daelimtransformer.com\/de\/transformer-specifications.html\">Ein umfassender Leitfaden zu Transformator-Spezifikationen<\/a><\/p>\n<p><a id=\"mdnTags11\" class=\"mdnTags\" name=\"mdn11\" data-index=\"11\"><\/a><\/p>\n<h2><span class=\"ez-toc-section\" id=\"How_Much_Power_And_Specification_Does_An_25_MVA_Transformer_Have\"><\/span>Wie viel Leistung und Spezifikation hat ein 25 MVA Transformator?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><img decoding=\"async\" style=\"width: 600px; height: 446px;\" title=\"25 mva Transformator\" src=\"\/media\/115\/25-mva-transformer-for-usa.webp\" alt=\"25 mva Transformator\" \/><br \/>\nEin 25 MVA Transformator hat eine prim\u00e4re Wicklung von 24,9 kV und eine sekund\u00e4re Wicklung von 4,16 kV (der Transformator, den Daelim in die Vereinigten Staaten exportiert hat). Er kann Strombedarf von bis zu 25000 kVA bew\u00e4ltigen.<\/p>\n<p>Wie Sie sehen k\u00f6nnen, wird die Stromverteilung in gr\u00f6\u00dferen, vielf\u00e4ltigeren Gebieten am besten von 25 MVA Transformatoren bedient.<\/p>\n<p>Sie erleichtern den Wechsel von der \u00fcber das Versorgungsnetz bereitgestellten Elektrizit\u00e4t zu der von alternativen Quellen, wie z.B. Generatoren.<\/p>\n<p>Daelim hat \u00fcber ein Jahrzehnt eine Genehmigungsquote von 100% aufrecht erhalten, was garantiert, dass jeder Transformator, den es versendet, gr\u00fcndlich getestet wurde.<\/p>\n<ul>\n<li>Nennleistung: 25 MVA<\/li>\n<li>\u00c4quivalentes KV: 25.000 KVA<\/li>\n<li>Frequenz: 50Hz<\/li>\n<li>Phasierung: Drei<\/li>\n<li>K\u00fchlungsart: ONAF<\/li>\n<li>Hauptspannung: 24,9 KV<\/li>\n<li>2. Spannung: 4,16KV<\/li>\n<li>Vektor-Klasse: Dyn11<\/li>\n<li>Impedanz: 6,5 %<\/li>\n<li>Abgriffwechsel: OLTC<\/li>\n<li>Abgriffsbereich: +10% in Schritten von 1.25% 7 Abgriffe<\/li>\n<li>Zubeh\u00f6r: Standard<\/li>\n<li>Material: Kupfer<\/li>\n<li>Leerlaufverlust: 8 KW<\/li>\n<li>Lastverlust: 66,5 KW<\/li>\n<\/ul>\n<p><a id=\"mdnTags12\" name=\"mdn12\" data-index=\"12\"><\/a><\/p>\n<p><span style=\"color: #27ae60;\"><strong>Jetzt erh\u00e4ltlich:\u00a0<\/strong><\/span><strong><a href=\"https:\/\/www.daelimtransformer.com\/de\/20-mva-transformer-daelim.html\"><span style=\"color: #d35400;\">20 MVA Transformator: Der ultimative FAQs Leitfaden\u00a0<\/span><\/a><\/strong><\/p>\n<p><a id=\"mdnTags13\" class=\"mdnTags\" name=\"mdn13\" data-index=\"13\"><\/a><\/p>\n<h2><span class=\"ez-toc-section\" id=\"How_Much_Power_And_Specification_Does_An_315_MVA_Transformer_Have\"><\/span>Wie viel Leistung und Spezifikation hat ein 31,5 MVA Transformator?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Ein 31,5 MVA Transformator hat neben seiner Hauptwicklung von 132 kV sekund\u00e4re Wicklungen mit 11 kV. Er kann Leistungsanforderungen von bis zu 31.500 KVA bew\u00e4ltigen.<\/p>\n<p>Daher sind 31,5 MVA Transformatoren die beste Option f\u00fcr die Verteilung von Strom \u00fcber weiterreichende, diversifizierte Gebiete.<\/p>\n<p>Er kann etwa 11600 kg \u00d6l halten und wiegt etwa 48000 Kilogramm. Aufgrund seiner niedrigen Flussdichte und magnetischen Schilde kann er hohen \u00dcbererregungen standhalten, ohne stark besch\u00e4digt zu werden.<\/p>\n<ul>\n<li>Nennleistung: 31,5 MVA<\/li>\n<li>\u00c4quivalente KV: 31.500 kVA<\/li>\n<li>Frequenz: 50Hz<\/li>\n<li>Phasierung: Drei<\/li>\n<li>K\u00fchlung: ONAN<\/li>\n<li>Spannungsverh\u00e4ltnis: 132000 \/ 11000 V<\/li>\n<li>Spannungsregelung: OLTC \u2013 Lastabgriffwechsel<\/li>\n<li>Abgriffbereich: +-12\u00d71,5%<\/li>\n<li>Verbindung: YNyn0<\/li>\n<li>Material: Kupfer<\/li>\n<\/ul>\n<p><a id=\"mdnTags14\" name=\"mdn14\" data-index=\"14\"><\/a><\/p>\n<p>Sie k\u00f6nnten genie\u00dfen:\u00a0<a href=\"https:\/\/www.daelimtransformer.com\/de\/30-mva-transformer.html\">Der ultimative Leitfaden f\u00fcr 30 MVA Transformatoren<\/a><\/p>\n<p><a id=\"mdnTags15\" class=\"mdnTags\" name=\"mdn15\" data-index=\"15\"><\/a><\/p>\n<h2><span class=\"ez-toc-section\" id=\"How_Much_Power_And_Specification_Does_An_35_MVA_Transformer_Have\"><\/span><a id=\"9\" name=\"9\"><\/a>Wie viel Leistung und Spezifikation hat ein 35 MVA Transformator?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><img decoding=\"async\" style=\"width: 578px; height: 475px;\" title=\"35 mva Transformator\" src=\"\/media\/115\/35-mva-transformer.webp\" alt=\"35 mva Transformator\" \/><br \/>\n35 MVA Transformator hat eine Hauptwicklung, die normalerweise mit 110 kV bewertet ist, und eine sekund\u00e4re Wicklung, die haupts\u00e4chlich mit 66 kV bewertet ist.<\/p>\n<p>Er kann elektrische Lasten von bis zu 35.000 kVA gleichzeitig aufnehmen.<\/p>\n<p>Insgesamt kann er 13.500 Liter \u00d6l transportieren und wiegt 55.000 Kilogramm.<\/p>\n<p>35 MVA Transformatoren werden h\u00e4ufig in gro\u00dfen Geb\u00e4uden eingesetzt, da sie zuverl\u00e4ssig sind und die elektrischen Anforderungen der Struktur erf\u00fcllen.<\/p>\n<ul>\n<li>Nennleistung: 35 MVA<\/li>\n<li>\u00c4quivalente KV: 35.000 KVA<\/li>\n<li>Frequenz: 60Hz<\/li>\n<li>Phasierung: Drei<\/li>\n<li>K\u00fchltyp: ONAN<\/li>\n<li>Spannungsverh\u00e4ltnis \u2013 HV\/LV: 66000 \/ 11000<\/li>\n<li>Spannung: Abgrenzungswechselrichter<\/li>\n<li>Abtapbereich: \u00b12 \u00d7 2.25%<\/li>\n<li>Material: Kupfer<\/li>\n<\/ul>\n<p><a id=\"mdnTags16\" class=\"mdnTags\" name=\"mdn16\" data-index=\"16\"><\/a><\/p>\n<h2><span class=\"ez-toc-section\" id=\"How_Much_Power_And_Specification_Does_An_45_MVA_Transformer_Have\"><\/span><a id=\"10\" name=\"10\"><\/a>Wie viel Leistung und Spezifikation hat ein 45 MVA Transformator?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><img decoding=\"async\" style=\"width: 600px; height: 416px;\" title=\"45 mva Transformator\" src=\"\/media\/115\/45-mva-transformer.webp\" alt=\"45 mva Transformator\" \/><\/p>\n<p>Ein 45 MVA Transformator hat eine 132 Kilovolt (kV) Prim\u00e4rwicklung und eine 11 kV Sekund\u00e4rwicklung. Die internen L\u00fcfter und der OLTC in diesem Transformator halten alles k\u00fchl.<\/p>\n<p>Er kann elektrische Lasten von bis zu 45.000 kVA bew\u00e4ltigen.<\/p>\n<p>Er hat ein enormes Gewicht von 23000 Pfund und eine Lagerkapazit\u00e4t von 5100 kg \u00d6l. In jedem Fall sind die Zubeh\u00f6rteile flexibel.<\/p>\n<p>Um die hohe Spannung von der \u00dcbertragungsleitung auf ein Niveau zu reduzieren, das haupts\u00e4chlich in Haushalten und Unternehmen genutzt werden kann, wird h\u00e4ufig ein 45 MVA Transformator eingesetzt.<\/p>\n<ul>\n<li>Nennleistung: 45 MVA<\/li>\n<li>\u00c4quivalente KV: 45.000 KVA<\/li>\n<li>Frequenz: 50Hz<\/li>\n<li>Phasierung: Drei<\/li>\n<li>K\u00fchltyp: ONAN\/ONAF<\/li>\n<li>Hauptspannung: 132 kV<\/li>\n<li>Sekund\u00e4rspannung: 11kV<\/li>\n<li>Vektor-Klasse: YNd1<\/li>\n<li>Impedanz: 13%<\/li>\n<li>Abgriffwechsel: OLTC<\/li>\n<li>Abtapbereich: +4*1.25%, -12*1.25%<\/li>\n<li>Material: Kupfer<\/li>\n<\/ul>\n<p><a id=\"mdnTags17\" class=\"mdnTags\" name=\"mdn17\" data-index=\"17\"><\/a><\/p>\n<h2><span class=\"ez-toc-section\" id=\"How_Much_Power_And_Specification_Does_A_60_MVA_Transformer_Have\"><\/span><a id=\"11\" name=\"11\"><\/a>Wie viel Leistung und Spezifikation hat ein 60 MVA Transformator?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Oft hat die Prim\u00e4rspannung des 60 MVA Transformators 242 Kilovolt, und die Sekund\u00e4rspannung betr\u00e4gt 10,5 Kilovolt.<\/p>\n<p>Er kann elektrische Lasten von bis zu 60.000 KVA problemlos bew\u00e4ltigen. Dieser Hochspannungstransformator integriert ein ONAF-K\u00fchlsystem in sein Design.<\/p>\n<p>Ein 60 MVA Transformator wiegt typischerweise nahe 108.000 Kilo.<\/p>\n<p>Dar\u00fcber hinaus findet man einen 60 MVA Transformator typischerweise in Kraftwerken und er wird haupts\u00e4chlich eingesetzt, um die Spannung des vom Kraftwerk erzeugten Stroms zu erh\u00f6hen, bevor dieser haupts\u00e4chlich \u00fcber das Netz verteilt wird.<\/p>\n<ul>\n<li>Nennleistung: 60 MVA<\/li>\n<li>\u00c4quivalente KV: 60.000 KVA<\/li>\n<li>Frequenz: 50\/60Hz<\/li>\n<li>Phasierung: Drei<\/li>\n<li>K\u00fchlung: ONAF<\/li>\n<li>Leerlaufverlust: 28kw<\/li>\n<li>Lastverlust: 265kw<\/li>\n<li>Vektor-Klasse: YNd1<\/li>\n<li>Impedanzrate: 13.3%<\/li>\n<li>Abgriffbereich: NLTC a\u00b12*2.5%<\/li>\n<li>Material: Kupfer<\/li>\n<\/ul>\n<p><a id=\"mdnTags18\" class=\"mdnTags\" name=\"mdn18\" data-index=\"18\"><\/a>Jetzt kostenlos ausprobieren:\u00a0<a href=\"https:\/\/www.daelimtransformer.com\/de\/10mva-transformer.html\">10mva Transformator: Der ultimative FAQ-Leitfaden<\/a><\/p>\n<p><a id=\"mdnTags19\" class=\"mdnTags\" name=\"mdn19\" data-index=\"19\"><\/a><\/p>\n<h2><span class=\"ez-toc-section\" id=\"How_Much_Power_And_Specification_Does_A_70_MVA_Transformer_Have\"><\/span><a id=\"12\" name=\"12\"><\/a>Wie viel Leistung und Spezifikation hat ein 70 MVA Transformator?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Ein 70 MVA Transformator hat eine Hauptwicklung, die 220 kV erzeugt, und eine sekund\u00e4re Wicklung, die 30 kV erzeugt.<\/p>\n<p>Leistungsanforderungen von bis zu 70.000 kVA k\u00f6nnen normalerweise ohne Schwierigkeiten erf\u00fcllt werden.<\/p>\n<p>Ein 70 MVA Transformator ist ein Hochspannungstransformator, der f\u00fcr ONAN- und ONAF-K\u00fchlsysteme konzipiert ist.<\/p>\n<p>Der massive Tank eines 70 MVA Transformators tr\u00e4gt bis zu 38.200 Kilogramm \u00d6l und wiegt beeindruckende 131.000 kg.<\/p>\n<ul>\n<li>Nennleistung: 70 MVA<\/li>\n<li>\u00c4quivalente KV: 70.000 kVA<\/li>\n<li>Frequenz: 50\/60Hz<\/li>\n<li>Phasierung: Drei<\/li>\n<li>K\u00fchltyp: ONAN\/ONAF<\/li>\n<li>Abgriffbereich: +-8\u00d71.25%<\/li>\n<li>Temperaturanstieg: 50\/55 K<\/li>\n<li>Verbindung: YNyn0<\/li>\n<li>Abgriffbereich: NLTC a\u00b12*2.5%<\/li>\n<li>Material: Kupfer<\/li>\n<li>Abgriffwechsel: OLTC<\/li>\n<\/ul>\n<p><a id=\"mdnTags20\" name=\"mdn20\" data-index=\"20\"><\/a><\/p>\n<h2><span class=\"ez-toc-section\" id=\"How_Much_Power_And_Specification_Does_A_90_MVA_Transformer_Have\"><\/span><a id=\"13\" name=\"13\"><\/a>Wie viel Leistung und Spezifikation hat ein 90 MVA Transformator?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Die Prim\u00e4r- und Sekund\u00e4rwicklungen eines 90 MVA Transformators k\u00f6nnen jeweils 11 kV und 110 kV produzieren.<\/p>\n<p>Strom kann bis zu 90.000 kVA konstant geliefert werden.<\/p>\n<p>Dieser Hochspannungs-90 MVA Leistungstransformator ist speziell f\u00fcr den Betrieb mit der hohen Spannung konzipiert, die von ONAN- und ONAF-Klimaanlagen ben\u00f6tigt wird.<\/p>\n<p>Der Transport dieses 90 MVA Transformators erfordert sorgf\u00e4ltige Planung und die Durchf\u00fchrung mehrerer Phasen. Vor allem wegen Gr\u00f6\u00dfe und Gewicht (110 Tonnen).<\/p>\n<ul>\n<li>Nennleistung: 90 MVA<\/li>\n<li>\u00c4quivalente KV: 90.000 KVA<\/li>\n<li>Frequenz: 50\/60Hz<\/li>\n<li>Phasierung: Drei<\/li>\n<li>K\u00fchltyp: ONAN\/ONAF<\/li>\n<li>Temperatur: 60\/65K<\/li>\n<li>Impedanz: 14 %<\/li>\n<li>Material: Kupfer<\/li>\n<li>Vektor Klasse Dyn11\/ Yyn0<\/li>\n<li>Isolierung: Mineral\u00f6l<\/li>\n<li>Transport: Holzpalette, Holzkiste<\/li>\n<\/ul>\n<p><a id=\"mdnTags21\" name=\"mdn21\" data-index=\"21\"><\/a><\/p>\n<p>Weitere Informationen: <a href=\"https:\/\/www.daelimtransformer.com\/de\/100-mva-transformer.html\">Der ultimative FAQs-Leitfaden f\u00fcr Transformatoren mit 100 MVA<\/a><\/p>\n<\/div>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Electrical power transformers are the most common types of equipment used for power electricity, typically ranging in power ratings from 18 MVA to 90 MVA. They operate at voltages between 44 kV and 230 kV and are available in either a three-phase or single-phase configuration. These transformers can be either on-load tap-changing or off-circuit tap-changing. [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":7450,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[279],"tags":[],"class_list":["post-7449","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articles-news"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/posts\/7449","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/comments?post=7449"}],"version-history":[{"count":0,"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/posts\/7449\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/media\/7450"}],"wp:attachment":[{"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/media?parent=7449"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/categories?post=7449"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/tags?post=7449"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}