{"id":7568,"date":"2026-01-05T09:16:14","date_gmt":"2026-01-05T09:16:14","guid":{"rendered":"https:\/\/daelimtransformer.com\/?p=7568"},"modified":"2026-10-25T00:52:35","modified_gmt":"2026-10-24T16:52:35","slug":"differential-protection-of-uhv-transformer","status":"publish","type":"post","link":"https:\/\/www.daelimtransformer.com\/de\/differential-protection-of-uhv-transformer.html","title":{"rendered":"Differentialschutz von UHV-Transformatoren"},"content":{"rendered":"<figure class=\"wp-block-image size-full\"><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone wp-image-13774 size-full\" src=\"https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/01\/Differential-Protection-of-UHV-Transformer.jpg\" alt=\"Differentialschutz von UHV-Transformatoren\" width=\"700\" height=\"434\" srcset=\"https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/01\/Differential-Protection-of-UHV-Transformer.jpg 700w, https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/01\/Differential-Protection-of-UHV-Transformer-18x12.jpg 18w, https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/01\/Differential-Protection-of-UHV-Transformer-600x372.jpg 600w\" sizes=\"(max-width: 700px) 100vw, 700px\" \/><\/figure>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\">Der Differentialschutz von UHV-Transformatoren, auch als Ultrahochspannungstransformatoren bezeichnet, ist ein prim\u00e4res Hochgeschwindigkeits-Schutzkonzept f\u00fcr Ihren elektrischen Transformator. Dieses Konzept dient dazu, interne Fehler in Ihrem elektrischen Transformator zu erkennen, beispielsweise Kurzschl\u00fcsse oder Wicklungssch\u00e4den.<\/p>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\">Dieses Differentialschutzsystem vergleicht kontinuierlich den in Ihren Transformator einstr\u00f6menden Strom mit dem aus Ihrem Transformator ausstr\u00f6menden Strom. Dies geschieht mithilfe eines Stromwandlers, der dazu beitr\u00e4gt, das Ger\u00e4t abzuschalten, sobald ein Fehler erkannt wird.<\/p>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\">Das System st\u00fctzt sich zudem auf spezielle Relais, die eigens f\u00fcr diese Anwendung konzipiert und entwickelt wurden, um ein ungewolltes Ausl\u00f6sen des elektrischen Transformators zu verhindern. Ein solches ungewolltes Ausl\u00f6sen kann durch den Magnetisierungs-Einschaltstrom verursacht werden. Dieses System gew\u00e4hrleistet die Integrit\u00e4t des gesamten Differentialschutzsystems des UHV-Transformators.<\/p>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\">Damit stellt sich die Frage, warum dieser UHV-Transformator ein spezielles Differentialschutzsystem ben\u00f6tigt.<\/p>\r\n\r\n\r\n\r\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-block-buttons-is-layout-flex wp-container-core-buttons-is-layout-3e41869c\">\r\n<div class=\"wp-block-button quoteModal\"><a class=\"wp-block-button__link wp-element-button\">Preis anfragen<\/a><\/div>\r\n<\/div>\r\n\r\n\r\n\r\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Why_UHV_Transformers_Require_Specialized_Protection\"><\/span>Warum UHV-Transformatoren einen speziellen Schutz ben\u00f6tigen<span class=\"ez-toc-section-end\"><\/span><\/h2>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\">Der von Ihnen verwendete UHV-Transformator hat in der Regel einen Spannungsbereich von 1000 kV oder sogar noch h\u00f6her. Dieser Hochspannungsbetrieb bedingt eine \u00e4u\u00dferst komplexe interne Struktur des elektrischen Transformators, zu der die Spannungsregelungswicklung, die Kompensationswicklung und die umfangreiche Phasenverschiebungsanordnung des elektrischen Transformators geh\u00f6ren.<\/p>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\">Aufgrund all dieser \u00e4u\u00dferst komplexen und sensiblen Merkmale ist das herk\u00f6mmliche Einzonen-Differentialschutzschema nicht in der Lage, die f\u00fcr die Fehlererkennung bei Ultrahochspannungstransformatoren erforderlichen pr\u00e4zisen Vorg\u00e4nge auszuf\u00fchren. Der einzige Ansatz, der f\u00fcr die Fehlererkennung bei Ultrahochspannungstransformatoren tats\u00e4chlich zur Verf\u00fcgung steht, ist das Differentialschutzsystem des Ultrahochspannungstransformators.<\/p>\r\n\r\n\r\n\r\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Core_Operating_Principles_for_Differential_Protection_of_UHV_Transformers\"><\/span>Grundlegende Betriebsprinzipien f\u00fcr den Differentialschutz von UHV-Transformatoren<span class=\"ez-toc-section-end\"><\/span><\/h2>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\">Obwohl der Differentialschutz von Ultrahochspannungstransformatoren ein relativ modernes Schutzsystem ist, basiert er auf denselben grundlegenden elektrischen Prinzipien und Gesetzen, die auch bei den meisten anderen elektrischen Schutzsystemen zum Tragen kommen.<\/p>\r\n\r\n\r\n\r\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" class=\"alignnone wp-image-13775 size-full\" src=\"https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/01\/Core-Operating-Principles-for-Differential-Protection-of-UHV-Transformers.webp\" alt=\"Grundlegende Betriebsprinzipien f\u00fcr den Differentialschutz von UHV-Transformatoren\" width=\"467\" height=\"314\" srcset=\"https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/01\/Core-Operating-Principles-for-Differential-Protection-of-UHV-Transformers.webp 467w, https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/01\/Core-Operating-Principles-for-Differential-Protection-of-UHV-Transformers-18x12.webp 18w\" sizes=\"(max-width: 467px) 100vw, 467px\" \/><\/figure>\r\n\r\n\r\n\r\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Works_on_Kirchhoffs_Current_Law\"><\/span>Arbeiten zum Kirchhoffschen Stromgesetz<span class=\"ez-toc-section-end\"><\/span><\/h3>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\">Demnach ist unter normalen Betriebsbedingungen eines elektrischen Transformators der in den Transformator eintretende Strom gleich dem aus dem Transformator austretenden Strom. Die Stromwandler auf der Hoch- und Niederspannungsseite des elektrischen Transformators sind so kalibriert, dass sich ihre Sekund\u00e4rstr\u00f6me gegenseitig aufheben; dadurch ergibt sich am Ausgang ein Netto-Differenzstrom von Null.<\/p>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\">Wenn ein interner Fehler im elektrischen Transformator auftritt \u2013 das hei\u00dft, wenn ein Kurzschluss vorliegt oder eine Besch\u00e4digung der Wicklungen im Transformator vorliegt \u2013, f\u00fchrt dieser Fehler zu einer Unausgeglichenheit oder einer St\u00f6rung des Strombalanzzustands des elektrischen Transformators. Der daraus resultierende unsymmetrische Strom flie\u00dft durch das Relais, das speziell daf\u00fcr ausgelegt ist, umgehend ein Ausl\u00f6sesignal zu erzeugen, um den Transformator vom nationalen Stromnetz zu trennen.<\/p>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\">Um ein ungewolltes Ausl\u00f6sen des elektrischen Transformators und dessen Trennung vom nationalen Netz zu vermeiden, verf\u00fcgt das Relais, das den Fehler zun\u00e4chst erkennt, \u00fcber eine Funktion, bei der sich die D\u00e4mpfungsspulen entsprechend der St\u00e4rke des Durchgangsstroms anpassen.<\/p>\r\n\r\n\r\n\r\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" class=\"wp-image-13764\" src=\"https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/10\/uhv-diagram-differential-2.webp\" alt=\"Differentialschutzschema zum Vergleich der in den gesch\u00fctzten Transformatorbereich einstr\u00f6menden und aus ihm ausstr\u00f6menden Str\u00f6me\" width=\"1400\" height=\"780\" srcset=\"https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/10\/uhv-diagram-differential-2.webp 1400w, https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/10\/uhv-diagram-differential-2-768x428.webp 768w, https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/10\/uhv-diagram-differential-2-18x10.webp 18w, https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/10\/uhv-diagram-differential-2-600x334.webp 600w\" sizes=\"(max-width: 1400px) 100vw, 1400px\" \/><\/figure>\r\n\r\n\r\n\r\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Operating_Characteristics_and_Mathematical_Formulation\"><\/span>Betriebseigenschaften und mathematische Formulierung<span class=\"ez-toc-section-end\"><\/span><\/h2>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\">Das Differentialschutzsystem eines UHV-Transformators wird nicht ausschlie\u00dflich durch das Vorliegen eines Differenzstroms ausgel\u00f6st. Die modernsten numerischen Relais, die in diesen Systemen zum Einsatz kommen, nutzen eine prozentuale Differentialcharakteristik, um Fehler und andere transiente Betriebszust\u00e4nde zu erkennen.<\/p>\r\n\r\n\r\n\r\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Basic_Operating_Principle\"><\/span>Grundlegendes Funktionsprinzip<span class=\"ez-toc-section-end\"><\/span><\/h3>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\">Im Differentialschutzsystem des UHV-Transformators misst das Relais kontinuierlich den in den gesch\u00fctzten Transformatorbereich ein- und ausflie\u00dfenden Strom. Dies geschieht mithilfe des Stromwandlers. Unter normalen Betriebsbedingungen oder bei Auftreten externer Fehler sind diese Str\u00f6me nach dem Verh\u00e4ltnis- und Phasenkompensationsvorgang nahezu gleich gro\u00df. Dies f\u00fchrt zu einem sehr geringen oder gar keinem Differenzstrom.<\/p>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\">Bei jeder Art von internem Fehler, wie beispielsweise einem Kurzschluss in der Wicklung oder einem Ausfall des <a href=\"https:\/\/www.daelimtransformer.com\/de\/transformer-insulation.html\">Transformatorisolierung<\/a>, wird das Strombilanzgleichgewicht des Transformators gest\u00f6rt. Sobald das Strombilanzgleichgewicht des Transformators gest\u00f6rt ist und die Differenz den Ansprechschwellenwert des Relais \u00fcberschreitet, l\u00f6st das Differenzstromschutzsystem des Transformators den zugeh\u00f6rigen Leistungsschalter aus. Dadurch wird der Fehlerbereich bzw. der Transformator vollst\u00e4ndig vom gesamten Stromverteilungsnetz getrennt.<\/p>\r\n\r\n\r\n\r\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Mathematical_Formulation\"><\/span>Mathematische Formulierung<span class=\"ez-toc-section-end\"><\/span><\/h3>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\"><strong>Differenzstrom (Betriebsstrom)<\/strong><\/p>\r\n\r\n<p class=\"has-text-align-center wp-block-paragraph\"><strong>I<sub>diff<\/sub> = | I<sub>1<\/sub> \u2212 I<sub>2<\/sub> |<\/strong><\/p>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\"><strong>I1 ist der Strom, der auf einer Seite des Transformators gemessen wird<\/strong><\/p>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\">I2 ist der Strom, der nach Kompensation des \u00dcbersetzungsverh\u00e4ltnisses und des Phasenwinkels auf der gegen\u00fcberliegenden Seite gemessen wird.<\/p>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\">Die Stromdifferenz stellt hier die Gr\u00f6\u00dfe des Stromsymmetriefehlers innerhalb des Schutzbereichs dar.<\/p>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\"><strong>Begrenzungsstrom<\/strong><\/p>\r\n\r\n<p class=\"has-text-align-center wp-block-paragraph\"><strong>I<sub>Rest<\/sub> = ( | I<sub>1<\/sub> | + | I<sub>2<\/sub> | ) \/ 2<\/strong><\/p>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\">Der oben angegebene Begrenzungsstrom spiegelt den Belastungszustand des Transformators und den im Transformator vorhandenen Durchgangsstrom wider.<\/p>\r\n\r\n\r\n\r\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Percentage_Differential_Operating_Characteristic\"><\/span>Prozentuale Differenz-Betriebskennlinie<span class=\"ez-toc-section-end\"><\/span><\/h3>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\">Das im Differentialschutzsystem des Transformators verwendete Relais l\u00f6st erst aus, wenn die Stromdifferenz den Ausl\u00f6sepunkt des Relais \u00fcberschreitet.<\/p>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\"><strong>Hier<\/strong><\/p>\r\n\r\n<p class=\"has-text-align-center wp-block-paragraph\"><strong>I<sub>diff<\/sub> &gt; K \u00d7 I<sub>Rest<\/sub> + I<sub>Abholung<\/sub><\/strong><\/p>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\"><strong>K steht f\u00fcr die prozentuale Abweichung (Steigung der R\u00fcckhaltekurve)<\/strong><\/p>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\"><strong>Der Messwert stellt den Differenzmessstrom dar.<\/strong><\/p>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\">Die oben dargestellte Gleichung erm\u00f6glicht es, dass sich die Ansprechschwelle des Transformatorrelais automatisch erh\u00f6ht, wenn der Begrenzungsstrom ansteigt. Dadurch wird das Relais bei externen Fehlern mit hohem Strom stabiler, bleibt aber gleichzeitig \u00e4u\u00dferst empfindlich gegen\u00fcber echten internen Transformatorfehlern.<\/p>\r\n\r\n\r\n\r\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Dual-Slope_Percentage_Restraint_Characteristic\"><\/span>Prozentuale R\u00fcckhaltecharakteristik bei zwei Steigungen<span class=\"ez-toc-section-end\"><\/span><\/h3>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\">Der gro\u00dfe UHV-Transformator f\u00fcr ihr Differentialschutzsystem verwendet in der Regel eine prozentuale Begrenzungscharakteristik mit zwei Steigungen anstelle einer einzigen festen Steigung. Aus diesem Grund verwendet das Relais des Differentialschutzsystems im Niedrigstrombereich eine relativ geringe Begrenzungssteigung, um eine hohe Empfindlichkeit zu gew\u00e4hrleisten. Dies dient der Erkennung von Wicklungsfehlern, Windungsfehlern und Isolationsfehlern mit geringem Ausma\u00df.<\/p>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\">Mit steigendem Transformator-Halte-Strom schaltet das Relais automatisch auf eine steilere Ansprechkurve um. Diese h\u00f6here Haltekraft verbessert die Stabilit\u00e4t des Transformators bei schweren externen Kurzschl\u00fcssen, bei S\u00e4ttigungszust\u00e4nden des Stromwandlers sowie bei anderen transienten Ereignissen. All diese Ereignisse k\u00f6nnten andernfalls einen falschen Differenzstrom erzeugen, der das Schutzsystem ausl\u00f6st und den Transformator abschaltet.<\/p>\r\n\r\n\r\n\r\n\r\n\r\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-13763\" src=\"https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/10\/uhv-photo-dual-slope.webp\" alt=\"Prozentuale Begrenzungskennlinie mit doppelter Steigung f\u00fcr UHV-Transformatoren\" width=\"934\" height=\"580\" \/><\/figure>\r\n\r\n<p class=\"wp-block-paragraph\">Typische Einstellungen, die bei elektrischen Transformatoren mit numerischen Relais in Netzqualit\u00e4t verwendet werden, sind<\/p>\r\n\r\n\r\n\r\n<figure class=\"wp-block-table\">\r\n<table>\r\n<thead>\r\n<tr>\r\n<th>Parameter<\/th>\r\n<th>Typischer Bereich<\/th>\r\n<\/tr>\r\n<\/thead>\r\n<tbody>\r\n<tr>\r\n<td>Abgreifstrom<\/td>\r\n<td>0,2\u20130,4 pu<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>Piste 1<\/td>\r\n<td>20\u201330%<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>Piste 2<\/td>\r\n<td>40\u201370%<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>Breakpoint-Strom<\/td>\r\n<td>2\u20134 Punkte<\/td>\r\n<\/tr>\r\n<\/tbody>\r\n<\/table>\r\n<\/figure>\r\n\r\n\r\n\r\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Percentage_Restraint_Characteristic_Curve\"><\/span>Kennlinie f\u00fcr die prozentuale R\u00fcckhaltung<span class=\"ez-toc-section-end\"><\/span><\/h3>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\">In Differentialschutzsystemen f\u00fcr Ultrahochspannungstransformatoren lassen sich die Ausl\u00f6secharakteristiken durch eine Kurve darstellen, n\u00e4mlich die prozentuale R\u00fcckhalte-Vorspannungskurve. Dabei stellt die horizontale Achse den R\u00fcckhaltestrom dar, w\u00e4hrend die vertikale Achse des Diagramms den Differenzstrom angibt.<\/p>\r\n\r\n\r\n\r\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-13765\" src=\"https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/10\/uhv-diagram-restraint-2.webp\" alt=\"Prozentuale R\u00fcckhaltecharakteristikkurve mit doppelter Steigung f\u00fcr den Differentialschutz von UHV-Transformatoren\" width=\"1400\" height=\"860\" srcset=\"https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/10\/uhv-diagram-restraint-2.webp 1400w, https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/10\/uhv-diagram-restraint-2-768x472.webp 768w, https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/10\/uhv-diagram-restraint-2-18x12.webp 18w, https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/10\/uhv-diagram-restraint-2-600x369.webp 600w\" sizes=\"(max-width: 1400px) 100vw, 1400px\" \/><\/figure>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\"><strong>In der obigen Grafik<\/strong><\/p>\r\n\r\n\r\n\r\n<ul class=\"wp-block-list\">\r\n<li>Der Bereich unterhalb der Betriebskurve im Diagramm stellt den Einschr\u00e4nkungsbereich f\u00fcr das Relais des Differentialschutzsystems dar, in dem das Relais unter normalen Betriebslastbedingungen des Transformators stabil bleibt. Es bleibt auch w\u00e4hrend der Einschaltung des Transformators und bei externen Fehlern stabil.<\/li>\r\n\r\n\r\n\r\n<li>Der Bereich oberhalb der Kurve stellt die Betriebsbereiche dar, in denen das Transformatorrelais interne Fehler des Transformators und andere St\u00f6rungen erkennt und einen Abschaltbefehl ausl\u00f6st.<\/li>\r\n\r\n\r\n\r\n<li>Mit steigendem Sperrstrom im Transformator ben\u00f6tigt das Relais einen proportional h\u00f6heren Differenzstrom, der durch den Transformator flie\u00dft, bevor es ausl\u00f6st. Dies erh\u00f6ht die Sicherheit, ohne die Fehlerempfindlichkeit zu beeintr\u00e4chtigen.<\/li>\r\n<\/ul>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\">Bei Ultrahochspannungstransformatoren, die mit einer Spannung von 800 kV und mehr betrieben werden, sind die oben dargestellten adaptiven Betriebskennlinien von entscheidender Bedeutung. Dies liegt an dem sehr hohen Durchgangsstrom des Transformators, den komplexen Wicklungsanordnungen und der erh\u00f6hten Wahrscheinlichkeit einer S\u00e4ttigung des Stromwandlers.<\/p>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\">In Verbindung mit harmonischer D\u00e4mpfung und fortschrittlichen numerischen Algorithmen gew\u00e4hrleistet die prozentuale Differentialcharakteristik eine schnelle Fehlerbeseitigung im Transformator und minimiert gleichzeitig das Risiko unn\u00f6tiger Transformatorausf\u00e4lle.<\/p>\r\n\r\n\r\n\r\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Key_Differential_Protection_Schemes_for_UHV\"><\/span>Wichtige Differentialschutzkonzepte f\u00fcr UHV<span class=\"ez-toc-section-end\"><\/span><\/h2>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/www.daelimtransformer.com\/de\/power-transformer.html\">Die Ultrahochspannungstransformatoren<\/a> sind sehr komplexe Einheiten, und ein einziges standardm\u00e4\u00dfiges L\u00e4ngsdifferentialschutzsystem reicht zur Fehlererkennung nicht aus. Dies erfordert eine Mehrzonen-Segmentierung und eine Kombination mehrerer Systeme, um Fehler vollst\u00e4ndig zu erkennen und Schutz zu gew\u00e4hrleisten.<\/p>\r\n\r\n\r\n\r\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Longitudinal_Differential_Protection\"><\/span>L\u00e4ngs-Differentialschutz<span class=\"ez-toc-section-end\"><\/span><\/h3>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\">Dieses Schutzsystem deckt den gro\u00dfen Prim\u00e4rbereich des gesamten elektrischen Transformators ab. Dieses L\u00e4ngsdifferentialschutzsystem eignet sich zwar gut zur Erkennung gr\u00f6\u00dferer Phasen-zu-Phasen-Fehler im elektrischen Transformator, seine Empfindlichkeit nimmt jedoch erheblich ab, wenn es zur Erkennung kleinerer Windungsfehler in der Regelwicklung eingesetzt wird.<\/p>\r\n\r\n\r\n\r\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Split-Side_Differential_Protection\"><\/span>Geteilter Differentialschutz<span class=\"ez-toc-section-end\"><\/span><\/h3>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\">Dieses Schutzsystem zielt auf bestimmte Bereiche wie die Hauptserienwicklung und die gemeinsame Wicklung des elektrischen Transformators ab. Es deckt zwar einen kleineren Bereich ab, erh\u00f6ht jedoch die Empfindlichkeit des Erkennungssystems erheblich, wodurch dieses in der Lage ist, <a href=\"https:\/\/www.daelimtransformer.com\/de\/transformer-insulation-failure.html\">interne Kurzschl\u00fcsse<\/a>.<\/p>\r\n\r\n\r\n\r\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Voltage-Regulating_Winding_Differential_Protection\"><\/span>Differentialschutz mit Spannungsregelungswicklung<span class=\"ez-toc-section-end\"><\/span><\/h3>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\">Dieses Schutzsystem f\u00fcr den Ultrahochspannungstransformator bietet einen hochsensiblen, speziell auf die Spannungsregelungs- und Kompensationswicklungen des Ultrahochspannungstransformators zugeschnittenen Schutz.<\/p>\r\n\r\n\r\n\r\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Stability_and_Security_Logic\"><\/span>Stabilit\u00e4ts- und Sicherheitslogik<span class=\"ez-toc-section-end\"><\/span><\/h2>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\">Bei der Auslegung des Fehlererkennungssystems f\u00fcr den Ultrahochspannungstransformator muss anhand der folgenden Methoden zwischen tats\u00e4chlichen Fehlern und transienten Ph\u00e4nomenen unterschieden werden.<\/p>\r\n\r\n\r\n\r\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Harmonic_Restraint\"><\/span>Harmonische Zur\u00fcckhaltung<span class=\"ez-toc-section-end\"><\/span><\/h3>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\">Wenn ein Ultrahochspannungstransformator im unbelasteten Zustand unter Spannung gesetzt wird, kann ein hoher Magnetisierungs-Einschaltstrom auftreten. Dieser Strom kann vom Schutzsystem des Transformators als interner Fehler interpretiert werden. Dies liegt daran, dass der Einschaltstrom stark verzerrt ist und viele sekund\u00e4re Oberschwingungen enth\u00e4lt. Dies l\u00e4sst sich verhindern, wenn die Relais \u00fcber eine Funktion zur Unterdr\u00fcckung der zweiten Oberschwingung verf\u00fcgen, um ein Ausl\u00f6sen des Transformators aufgrund dieses Stroms zu verhindern.<\/p>\r\n\r\n\r\n\r\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Fifth_Harmonic_Restraint\"><\/span>F\u00fcnfte harmonische Einschr\u00e4nkung<span class=\"ez-toc-section-end\"><\/span><\/h3>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\">Die Oberwellenunterdr\u00fcckung sch\u00fctzt den elektrischen Transformator vor einer \u00dcbererregung, die bei hohen Netzspannungen im elektrischen Transformator auftreten kann. Dieser spezielle Zustand, der als Unterdr\u00fcckung der f\u00fcnften Oberwelle bezeichnet wird, erzeugt eine starke f\u00fcnfte Oberwellenkomponente im elektrischen Transformator.<\/p>\r\n\r\n\r\n\r\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"CT_Saturation_Compensation\"><\/span>CT-S\u00e4ttigungskompensation<span class=\"ez-toc-section-end\"><\/span><\/h3>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\">Diese Kompensation dient dazu, externe Fehler zu kompensieren, die zu einer S\u00e4ttigung der Stromwandler f\u00fchren k\u00f6nnen. Die Verhinderung dieser externen Fehler ist von gro\u00dfer Bedeutung, da sie einen Differenzstrom im Stromwandlerkreis verursachen k\u00f6nnen. Die modernen, numerisch gesteuerten Relais der Stromwandler nutzen Algorithmen, um solche Situationen zu erkennen und tragen dazu bei, das System zu stabilisieren und es vor unerw\u00fcnschten Ausl\u00f6sungen jeglicher Art zu sch\u00fctzen.<\/p>\r\n\r\n\r\n\r\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Conclusion\"><\/span>Fazit<span class=\"ez-toc-section-end\"><\/span><\/h2>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-12960\" src=\"https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/06\/daelim-transformer-heavy-duty-transformer-factory.webp\" alt=\"daelim transformer schwerer Transformator Fabrik\" width=\"1398\" height=\"600\" srcset=\"https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/06\/daelim-transformer-heavy-duty-transformer-factory.webp 1398w, https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/06\/daelim-transformer-heavy-duty-transformer-factory-768x330.webp 768w, https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/06\/daelim-transformer-heavy-duty-transformer-factory-18x8.webp 18w, https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/06\/daelim-transformer-heavy-duty-transformer-factory-600x258.webp 600w\" sizes=\"(max-width: 1398px) 100vw, 1398px\" \/><\/p>\r\n<p>Ultrahochspannungs-Transformatoren ben\u00f6tigen ein spezielles Differentialschutzsystem, da das herk\u00f6mmliche Einzonen-Differentialschutzschema nicht effizient genug ist, um Ultrahochspannungs-Transformatoren zu sch\u00fctzen. Diese Transformatoren weisen einen sehr komplexen elektrischen Aufbau auf und erfordern daher ein spezielles Schutzsystem. Daelim Transformer entwickelt und fertigt f\u00fcr seine Kunden Ultrahochspannungstransformatoren mit Differentialschutzsystemen, und unsere Transformatoren entsprechen internationalen Normen wie IEEE, ANSI, CSA und anderen. Bei Fragen und f\u00fcr Angebote wenden Sie sich bitte an, <a href=\"https:\/\/www.daelimtransformer.com\/de\/contact-us\/\">kontaktieren Sie uns<\/a>.<\/p>\r\n\r\n\r\n\r\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-block-buttons-is-layout-flex wp-container-core-buttons-is-layout-3e41869c\">\r\n<div class=\"wp-block-button quoteModal\"><a class=\"wp-block-button__link wp-element-button\">Jetzt ein Angebot anfordern<\/a><\/div>\r\n<\/div>\r\n\r\n\r\n\r\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"FAQ\"><\/span><span id=\"FAQ\" class=\"ez-toc-section\"><\/span><strong>H\u00e4ufig gestellte Fragen<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\r\n\r\n\r\n\r\n<div class=\"saswp-faq-block-section\">\r\n<ol style=\"list-style-type: none;\">\r\n<li style=\"list-style-type: none;\">\r\n<h5 class=\"saswp-faq-question-title\"><span class=\"ez-toc-section\" id=\"What_is_the_definition_of_ultra-high_voltage\"><\/span><span id=\"What_is_the_definition_of_ultra_high_voltage\" class=\"ez-toc-section\"><\/span><strong>Wie lautet die Definition von Ultrahochspannung?<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h5>\r\n<p class=\"saswp-faq-answer-text\">Ein Transformator, dessen Spannung den Wert von 800 kV \u00fcberschreitet, wird als Ultrahochspannungstransformator bezeichnet.<\/p>\r\n<\/li>\r\n<li style=\"list-style-type: none;\">\r\n<h5 class=\"saswp-faq-question-title\"><span class=\"ez-toc-section\" id=\"What_is_the_main_application_for_UHV_transformers\"><\/span><span id=\"What_is_the_main_application_for_UHV_transformers\" class=\"ez-toc-section\"><\/span><strong>Was ist der Hauptanwendungsbereich von UHV-Transformatoren?<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h5>\r\n<p class=\"saswp-faq-answer-text\">Sie dienen dazu, gro\u00dfe Strommengen \u00fcber gro\u00dfe Entfernungen mit minimalen Energieverlusten zu \u00fcbertragen<\/p>\r\n<\/li>\r\n<\/ol>\r\n<\/div>\r\n\r\n<p>&nbsp;<\/p>","protected":false},"excerpt":{"rendered":"<p>The differential protection of UHV Transformers, also known as the Ultra High Voltage transformer, is a primary high-speed protection scheme for your electrical transformer. This scheme is used to detect the internal faults in your electrical transformer, faults like short circuits or winding damage in the transformer. This differential protection system continuously compares the current [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":13774,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[279],"tags":[],"class_list":["post-7568","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articles-news"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/posts\/7568","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/comments?post=7568"}],"version-history":[{"count":9,"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/posts\/7568\/revisions"}],"predecessor-version":[{"id":13776,"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/posts\/7568\/revisions\/13776"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/media\/13774"}],"wp:attachment":[{"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/media?parent=7568"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/categories?post=7568"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/tags?post=7568"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}