{"id":7622,"date":"2026-01-05T09:29:39","date_gmt":"2026-01-05T09:29:39","guid":{"rendered":"https:\/\/daelimtransformer.com\/?p=7622"},"modified":"2026-10-25T00:41:11","modified_gmt":"2026-10-24T16:41:11","slug":"comprehensive-analysis-of-large-transformer-faults-by-gas-chromatography","status":"publish","type":"post","link":"https:\/\/www.daelimtransformer.com\/de\/comprehensive-analysis-of-large-transformer-faults-by-gas-chromatography.html","title":{"rendered":"Umfassende Analyse von Gro\u00dftransformatorfehlern durch Gaschromatographie"},"content":{"rendered":"<figure class=\"wp-block-image size-full\"><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone wp-image-13777 size-full\" src=\"https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/01\/Comprehensive-Analysis-of-Large-Transformer-Faults-by-Gas-Chromatography.jpg\" alt=\"Umfassende Analyse von Gro\u00dftransformatorfehlern durch Gaschromatographie\" width=\"1376\" height=\"768\" srcset=\"https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/01\/Comprehensive-Analysis-of-Large-Transformer-Faults-by-Gas-Chromatography.jpg 1376w, https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/01\/Comprehensive-Analysis-of-Large-Transformer-Faults-by-Gas-Chromatography-768x429.jpg 768w, https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/01\/Comprehensive-Analysis-of-Large-Transformer-Faults-by-Gas-Chromatography-18x10.jpg 18w, https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/01\/Comprehensive-Analysis-of-Large-Transformer-Faults-by-Gas-Chromatography-600x335.jpg 600w\" sizes=\"(max-width: 1376px) 100vw, 1376px\" \/><\/figure>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\">Die gro\u00dfen elektrischen Transformatoren geh\u00f6ren zu den wertvollsten und wichtigsten Anlagen in jedem Stromverteilungsnetz. Das Netz ist in so hohem Ma\u00dfe auf sie angewiesen, dass jeder Fehler oder jede St\u00f6rung an diesen gro\u00dfen Leistungstransformatoren die Stabilit\u00e4t und Effizienz des Netzes ernsthaft beeintr\u00e4chtigen kann.<\/p>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\">Dieser Artikel bietet eine sehr umfassende Analyse der Fehlererkennung bei gro\u00dfen Leistungstransformatoren mithilfe der Gaschromatographie. Wir werden erl\u00e4utern, welche Gase in gro\u00dfen elektrischen Transformatoren aufgrund verschiedener Fehlerarten entstehen und wie die Gaschromatographie dabei hilft, diese Gase nachzuweisen und so Fehler zu lokalisieren.<\/p>\r\n\r\n\r\n\r\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-block-buttons-is-layout-flex wp-container-core-buttons-is-layout-3e41869c\">\r\n<div class=\"wp-block-button quoteModal\"><a class=\"wp-block-button__link wp-element-button\">Preis anfragen<\/a><\/div>\r\n<\/div>\r\n\r\n\r\n\r\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"What_Is_Gas_Chromatography\"><\/span>Was ist Gaschromatographie?<span class=\"ez-toc-section-end\"><\/span><\/h2>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\">Die Gaschromatographie ist ein analytisches Laborverfahren, das zur Trennung und Identifizierung verschiedener einzelner Gase dient, die in jeder Art von Isolier\u00f6l gel\u00f6st sind, insbesondere in <a href=\"https:\/\/www.daelimtransformer.com\/de\/the-complete-guide-to-transformer-oil-dissolved-gas-analysis.html\">Transformator-Isolier\u00f6l<\/a>. Mit diesem Verfahren l\u00e4sst sich zudem sehr einfach die Menge der einzelnen Gase bestimmen, die im Isolier\u00f6l des Transformators nachgewiesen werden.<\/p>\r\n\r\n\r\n\r\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Why_Electrical_Transformers_Need_Gas_Chromatography_Analysis\"><\/span>Warum elektrische Transformatoren einer gaschromatographischen Analyse bed\u00fcrfen<span class=\"ez-toc-section-end\"><\/span><\/h2>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\">Transformator\u00f6l liefert wichtige Informationen \u00fcber den Zustand des Transformators und \u00fcber St\u00f6rungen, die im Inneren des Transformatorbeh\u00e4lters auftreten. Die gaschromatographische Analyse des Transformator\u00f6ls hilft uns, den Zustand des Transformators zu beurteilen und die im Inneren des Transformators auftretenden St\u00f6rungen zu verstehen.<\/p>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\">Elektrische Transformatoren sind so konzipiert und konstruiert, dass zur Isolierung verschiedener Teile des Transformators unterschiedliche Isoliermaterialien verwendet werden. Jeder elektrische Transformator kann mit mineralischem Isolier\u00f6l, Zellulosepapier als Isoliermaterial und <a href=\"https:\/\/www.daelimtransformer.com\/de\/transformer-insulation.html\">D\u00e4mmstoff aus Pressspan<\/a> zur Isolierung der Transformatorwicklung und der Kernbaugruppe.<\/p>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\">Diese Materialien k\u00f6nnen sich unter elektrischen oder thermischen Belastungen, die bei Spitzenbetriebsbedingungen des Transformatorbeh\u00e4lters auftreten, sehr leicht zersetzen. Dies h\u00e4ngt von der Art des Fehlers und der Temperatur ab, bei der dieser Fehler auftritt.<\/p>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\">Bei der Gaschromatographie des Transformator\u00f6ls werden diese Gase aus der jeweiligen Probe des Transformator\u00f6ls extrahiert. Dabei wird die spezifische Konzentration einzelner oder aller in der Probe enthaltenen Gase gemessen, und es werden Ergebnisse mit hoher Genauigkeit geliefert. Die Ergebnisse werden in der Regel in Teilen pro Million (ppm) oder in Mikrolitern pro Liter (\u00b5L\/L) angegeben. Diese Konzentration bildet die Grundlage f\u00fcr die Gasanalyse (DGA).<\/p>\r\n\r\n\r\n\r\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Why_Gas_Chromatography_Is_Important_for_Large_Transformers\"><\/span>Warum die Gaschromatographie f\u00fcr gro\u00dfe Transformatoren wichtig ist<span class=\"ez-toc-section-end\"><\/span><\/h2>\r\n<p>\r\n\r\n<\/p>\r\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/www.daelimtransformer.com\/de\/power-transformer.html\"><img decoding=\"async\" class=\"alignnone size-full wp-image-13781\" src=\"https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/01\/Why-Gas-Chromatography-Is-Important-for-Large-Transformers.webp\" alt=\"Warum die Gaschromatographie f\u00fcr gro\u00dfe Transformatoren wichtig ist\" width=\"1200\" height=\"764\" srcset=\"https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/01\/Why-Gas-Chromatography-Is-Important-for-Large-Transformers.webp 1200w, https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/01\/Why-Gas-Chromatography-Is-Important-for-Large-Transformers-768x489.webp 768w, https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/01\/Why-Gas-Chromatography-Is-Important-for-Large-Transformers-18x12.webp 18w, https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/01\/Why-Gas-Chromatography-Is-Important-for-Large-Transformers-600x382.webp 600w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/a><\/p>\r\n<p>Die Gaschromatographie hilft uns dabei, vorzeitige und pl\u00f6tzliche Ausf\u00e4lle gro\u00dfer elektrischer Transformatoren zu verhindern, indem sie Aufschluss \u00fcber den Zustand des Transformators und \u00fcber Fehler im Inneren des Transformatorbeh\u00e4lters gibt.<\/p>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\">Die gro\u00dfen Leistungstransformatoren, die in nationalen Stromnetzen und Verteilungsanlagen zum Einsatz kommen, kosten in der Regel mehrere hunderttausend Dollar. Die Herstellung dieser elektrischen Transformatoren dauert zudem mehrere Wochen, und f\u00fcr Transport und Installation sind mehrere Monate erforderlich.<\/p>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\">Der Austausch eines Leistungstransformators kostet Sie also nicht nur viel Geld, sondern erfordert auch mehrere Monate Arbeit, nur um den Transformator auszutauschen. Dies ist einer der Hauptgr\u00fcnde, warum diese Art von Pr\u00fcfung am Transformator durchgef\u00fchrt wird, bevor er zum Einbau transportiert wird, sowie w\u00e4hrend seiner gesamten Nutzungsdauer.<\/p>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\">Die Gaschromatographie bietet mehrere Vorteile, die im Folgenden aufgef\u00fchrt sind:<\/p>\r\n\r\n\r\n\r\n<ul class=\"wp-block-list\">\r\n<li>Die Gaschromatographie erm\u00f6glicht die fr\u00fchzeitige Erkennung von Isolationsverschlei\u00df im Inneren eines elektrischen Transformators.<\/li>\r\n\r\n\r\n\r\n<li>Die Analyse und Erkennung elektrischer St\u00f6rungen, bevor diese zu katastrophalen Ausf\u00e4llen f\u00fchren.<\/li>\r\n\r\n\r\n\r\n<li>Die Tests helfen uns dabei, die <a href=\"https:\/\/www.daelimtransformer.com\/de\/transformer-maintenance.html\">Wartungskosten<\/a> des elektrischen Transformators durch die fr\u00fchzeitige Erkennung kleiner Fehler, die im Inneren des Transformatorbeh\u00e4lters auftreten.<\/li>\r\n\r\n\r\n\r\n<li>Die Tests tragen dazu bei, die <a href=\"https:\/\/www.daelimtransformer.com\/de\/transformer-lifespan.html\">Lebensdauer des Transformators<\/a> indem vorzeitige Ausf\u00e4lle verhindert werden.<\/li>\r\n\r\n\r\n\r\n<li>Gaschromatographie-Pr\u00fcfungen tragen zudem dazu bei, ungeplante Betriebsausf\u00e4lle des Transformators zu vermeiden, indem sie bereits im Fr\u00fchstadium kleine Fehler erkennen, die zu unbeabsichtigten Ausfallzeiten des Transformators f\u00fchren k\u00f6nnen.<\/li>\r\n\r\n\r\n\r\n<li>Der Test tr\u00e4gt zudem dazu bei, die Betriebssicherheit zu verbessern, indem im Rahmen der planm\u00e4\u00dfigen Wartung zus\u00e4tzliche Schritte eingef\u00fchrt werden, mit denen sich kleinere St\u00f6rungen erkennen lassen.<\/li>\r\n<\/ul>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\">Die Analyse der gel\u00f6sten Gase wird bei gro\u00dfen Leistungstransformatoren in der Regel alle drei Monate, alle sechs Monate oder einmal j\u00e4hrlich durchgef\u00fchrt; dies h\u00e4ngt ganz vom Alter des zu pr\u00fcfenden Transformators und der Art der Anwendung ab.<\/p>\r\n\r\n\r\n\r\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" class=\"wp-image-13748\" src=\"https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/10\/dga-photo-substation-1.webp\" alt=\"Gro\u00dfe Leistungstransformatoren, die in einem Freiluft-Umspannwerk installiert sind und mittels Gasanalyse \u00fcberwacht werden\" width=\"1200\" height=\"675\" srcset=\"https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/10\/dga-photo-substation-1.webp 817w, https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/10\/dga-photo-substation-1-768x431.webp 768w, https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/10\/dga-photo-substation-1-18x10.webp 18w, https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/10\/dga-photo-substation-1-600x337.webp 600w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\r\n\r\n\r\n\r\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Dissolved_Gas_Analysis_Operating_Procedure\"><\/span>Betriebsanleitung zur Analyse gel\u00f6ster Gase<span class=\"ez-toc-section-end\"><\/span><\/h2>\r\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-13779\" src=\"https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/01\/Dissolved-Gas-Analysis-Operating-Procedure.webp\" alt=\"Betriebsanleitung zur Analyse gel\u00f6ster Gase\" width=\"1408\" height=\"651\" srcset=\"https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/01\/Dissolved-Gas-Analysis-Operating-Procedure.webp 1408w, https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/01\/Dissolved-Gas-Analysis-Operating-Procedure-768x355.webp 768w, https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/01\/Dissolved-Gas-Analysis-Operating-Procedure-18x8.webp 18w, https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/01\/Dissolved-Gas-Analysis-Operating-Procedure-600x277.webp 600w\" sizes=\"(max-width: 1408px) 100vw, 1408px\" \/><\/p>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\">Bei elektrischen Transformatoren dient das Transformator\u00f6l sowohl als Isoliermittel als auch als K\u00fchlmittel. Wenn im Inneren des elektrischen Transformators aufgrund eines Fehlers in den elektrischen Anschl\u00fcssen des Transformators ein au\u00dfergew\u00f6hnlicher Zustand auftritt, l\u00f6st die Energie chemische Bindungen im \u00d6l und in der festen Isolierung des Transformators auf. Bei der Zersetzung der Isolierung entstehen Gase wie beispielsweise<\/p>\r\n\r\n\r\n\r\n<ul class=\"wp-block-list\">\r\n<li>Wasserstoff<\/li>\r\n\r\n\r\n\r\n<li>Methan<\/li>\r\n\r\n\r\n\r\n<li>Ethan<\/li>\r\n\r\n\r\n\r\n<li>Ethylen<\/li>\r\n\r\n\r\n\r\n<li>Acetylen<\/li>\r\n\r\n\r\n\r\n<li>Kohlenmonoxid<\/li>\r\n\r\n\r\n\r\n<li>Kohlendioxid<\/li>\r\n<\/ul>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\">Um diese Gase zu untersuchen, werden folgende Schritte durchgef\u00fchrt<\/p>\r\n\r\n\r\n\r\n<ul class=\"wp-block-list\">\r\n<li>Entnahme der \u00d6lprobe aus dem Transformator<\/li>\r\n\r\n\r\n\r\n<li>Durchf\u00fchrung einer gaschromatographischen Analyse der \u00d6lprobe<\/li>\r\n\r\n\r\n\r\n<li>Es wird ein vollst\u00e4ndiger Bericht erstellt, aus dem hervorgeht, welche Gase gel\u00f6st sind und wie hoch ihre Konzentration in ppm ist.<\/li>\r\n\r\n\r\n\r\n<li>Das Ingenieurteam wertet die Gasverteilungsmuster aus, um m\u00f6gliche Fehler zu ermitteln<\/li>\r\n<\/ul>\r\n\r\n\r\n\r\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Fault_Gases_Detected_by_Gas_Chromatography\"><\/span>Mangelgase, die mittels Gaschromatographie nachgewiesen wurden<span class=\"ez-toc-section-end\"><\/span><\/h2>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\">Bei der Gaschromatographie von Transformator\u00f6l werden in der Regel die folgenden Gase nachgewiesen, die jeweils auf einen bestimmten Defekt zur\u00fcckzuf\u00fchren sind.<\/p>\r\n\r\n\r\n\r\n<figure class=\"wp-block-table\">\r\n<table>\r\n<thead>\r\n<tr>\r\n<th>Gas<\/th>\r\n<th>Chemische Formel<\/th>\r\n<th>Bedeutet<\/th>\r\n<\/tr>\r\n<\/thead>\r\n<tbody>\r\n<tr>\r\n<td>Wasserstoff<\/td>\r\n<td>H\u2082<\/td>\r\n<td>Teilentladung, Korona<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>Methan<\/td>\r\n<td>CH\u2084<\/td>\r\n<td>\u00dcberhitzung bei niedrigen Temperaturen<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>Ethan<\/td>\r\n<td>C\u2082H\u2086<\/td>\r\n<td>\u00d6l\u00fcberhitzung<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>Ethylen<\/td>\r\n<td>C\u2082H\u2084<\/td>\r\n<td>\u00dcberhitzung bei hohen Temperaturen<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>Acetylen<\/td>\r\n<td>C\u2082H\u2082<\/td>\r\n<td>Lichtbogenbildung und schwere elektrische St\u00f6rungen<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>Kohlenmonoxid<\/td>\r\n<td>CO<\/td>\r\n<td>Zersetzung der Papierisolierung<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>Kohlendioxid<\/td>\r\n<td>CO\u2082<\/td>\r\n<td>Alterung von Zellulose<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>Sauerstoff<\/td>\r\n<td>O\u2082<\/td>\r\n<td>Bewertung von Luftleckagen<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>Stickstoff<\/td>\r\n<td>N\u2082<\/td>\r\n<td>Luft eindringen<\/td>\r\n<\/tr>\r\n<\/tbody>\r\n<\/table>\r\n<\/figure>\r\n\r\n\r\n\r\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Relationship_Between_Fault_Temperature_and_Gas_Generation\"><\/span>Zusammenhang zwischen St\u00f6rungstemperatur und Gasentwicklung<span class=\"ez-toc-section-end\"><\/span><\/h2>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\">Fehler im Transformator f\u00fchren in der Regel zu zus\u00e4tzlicher Abw\u00e4rme im Inneren des Beh\u00e4lters. Bei unterschiedlichen Temperaturgrenzwerten k\u00f6nnen Isoliermaterialien und andere Faktoren verschiedene Gase erzeugen.<\/p>\r\n\r\n\r\n\r\n<figure class=\"wp-block-table\">\r\n<table>\r\n<thead>\r\n<tr>\r\n<th>Fehlertemperatur<\/th>\r\n<th>Wichtigste gef\u00f6rderte Gasarten<\/th>\r\n<\/tr>\r\n<\/thead>\r\n<tbody>\r\n<tr>\r\n<td>&lt;150 \u00b0C<\/td>\r\n<td>Methan<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>150\u2013300 \u00b0C<\/td>\r\n<td>Methan + Ethan<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>300\u2013700 \u00b0C<\/td>\r\n<td>Ethylen<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>&gt;700 \u00b0C<\/td>\r\n<td>Acetylen<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>\u00dcberhitzung von Zellulose<\/td>\r\n<td>CO + CO\u2082<\/td>\r\n<\/tr>\r\n<\/tbody>\r\n<\/table>\r\n<\/figure>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\">Es besteht ein einfacher Zusammenhang zwischen dem Temperaturanstieg und dem entstandenen Schaden: Je h\u00f6her die Fehlertemperatur ist, desto schwerwiegender sind die inneren Sch\u00e4den am Transformator.<\/p>\r\n\r\n\r\n\r\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-13731 size-full\" src=\"https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/10\/dga-diagram-temperature.webp\" alt=\"Tabelle der Temperaturbereiche von Verwerfungen und der von den einzelnen thermischen Verwerfungen freigesetzten gel\u00f6sten Gase\" width=\"1400\" height=\"820\" srcset=\"https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/10\/dga-diagram-temperature.webp 1400w, https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/10\/dga-diagram-temperature-768x450.webp 768w, https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/10\/dga-diagram-temperature-18x12.webp 18w, https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/10\/dga-diagram-temperature-600x351.webp 600w\" sizes=\"(max-width: 1400px) 100vw, 1400px\" \/><\/figure>\r\n\r\n\r\n\r\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Types_of_Transformer_Faults_Identified_By_Gas_Chromatography\"><\/span>Arten von Transformatorfehlern, die mittels Gaschromatographie identifiziert werden<span class=\"ez-toc-section-end\"><\/span><\/h2>\r\n\r\n\r\n\r\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Partial_Discharge\"><\/span>Teilentladung<span class=\"ez-toc-section-end\"><\/span><\/h3>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/www.daelimtransformer.com\/de\/what-is-iec-60270\/\">Die Teilentladung<\/a> Bei einem elektrischen Transformator handelt es sich um eine lokal begrenzte elektrische Entladung, die die Isolierung nicht vollst\u00e4ndig durchschl\u00e4gt. Diese Art von St\u00f6rung wird durch energiearme, langfristig auftretende Isolationssch\u00e4den und durch Feuchtigkeit bedingte Verschlei\u00dferscheinungen verursacht.<\/p>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\">Zu den vier h\u00e4ufigsten Gr\u00fcnden oder Ursachen f\u00fcr Teilentladungen z\u00e4hlen Feuchtigkeit im Transformator\u00f6l, Hohlr\u00e4ume im Isoliermaterial, gealtertes Isoliermaterial und gelegentlich auch Herstellungsfehler.<\/p>\r\n\r\n\r\n\r\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Corona_Discharge\"><\/span>Koronaentladung<span class=\"ez-toc-section-end\"><\/span><\/h3>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\">Dies ist haupts\u00e4chlich auf die hohe elektrische Feldst\u00e4rke im Umfeld der Leiter des Transformators zur\u00fcckzuf\u00fchren. Bei dieser Entladung entstehen im Transformator\u00f6l vor allem Wasserstoff und eine geringe Menge Methan. Dieser Fehler ist in der Regel weniger sch\u00e4dlich als andere Fehler wie Lichtbogenbildung, kann jedoch zu schwerwiegenderen St\u00f6rungen f\u00fchren, wenn er ignoriert wird.<\/p>\r\n\r\n\r\n\r\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Low_Temperature_Thermal_Fault\"><\/span>Thermischer Fehler bei niedrigen Temperaturen<span class=\"ez-toc-section-end\"><\/span><\/h3>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\">Wenn die elektrische Temperatur unter 300 Grad Celsius f\u00e4llt, spricht man bei einem elektrischen Transformator von einem Niedertemperatur-W\u00e4rmeschaden. Dies f\u00fchrt zur Bildung von Methan- und Ethangasen im Transformator\u00f6l. M\u00f6gliche Ursachen f\u00fcr diesen Niedertemperatur-W\u00e4rmeschaden sind lose elektrische Verbindungen, unzureichende K\u00fchlung, die Entstehung lokaler \u00dcberhitzungsstellen im Transformator sowie die \u00dcberlastung des Transformators durch die angeschlossene Last.<\/p>\r\n\r\n\r\n\r\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Medium_Temperature_Thermal_Fault\"><\/span>Thermischer Fehler bei mittlerer Temperatur<span class=\"ez-toc-section-end\"><\/span><\/h3>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\">Liegt die Temperatur des elektrischen Transformators innerhalb des Temperaturbereichs von 300 bis 700 Grad Celsius, gilt dies als thermischer Fehler mittlerer Temperatur. Dieser Fehler kann drei verschiedene Gase erzeugen, n\u00e4mlich Ethylen, Methan und Ethan. Diese Art von Fehler ist in der Regel auf einen schlechten Kontakt zwischen den leitenden Teilen des Transformators, einen hohen Widerstand zwischen den elektrischen Anschl\u00fcssen des Transformators sowie auf eine \u00dcberhitzung des Transformatorenkerns zur\u00fcckzuf\u00fchren.<\/p>\r\n\r\n\r\n\r\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"High_Temperature_Thermal_Fault\"><\/span>Thermischer Fehler bei hohen Temperaturen<span class=\"ez-toc-section-end\"><\/span><\/h3>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\">Wenn die Temperatur des elektrischen Transformators 700 Grad Celsius \u00fcberschreitet, spricht man von einem thermischen Hochtemperaturfehler. Dieser Fehler f\u00fchrt haupts\u00e4chlich zu einem hohen Ethylengehalt und einer erheblichen Menge an Acetylen im Transformator\u00f6l. Diese Art von Fehler wird haupts\u00e4chlich durch eine starke \u00dcberhitzung des elektrischen Transformators sowie durch Defekte oder Fehler im Transformatorkern verursacht, die auf die Erw\u00e4rmung der wichtigsten leitenden Teile des Transformators zur\u00fcckzuf\u00fchren sind.<\/p>\r\n\r\n\r\n\r\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Arcing\"><\/span>Lichtbogenbildung<span class=\"ez-toc-section-end\"><\/span><\/h3>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\">Lichtbogenbildung ist eine der h\u00e4ufigsten und zugleich gef\u00e4hrlichsten St\u00f6rungen, die in elektrischen Transformatoren auftreten k\u00f6nnen. Bei Lichtbogenbildung im Transformator k\u00f6nnen erhebliche Mengen an Acetylen sowie geringe Mengen an Wasserstoff und Ethylen entstehen. Die Ursachen f\u00fcr diese Lichtbogenbildung im elektrischen Transformator sind ein Ausfall der Wicklungsisolierung, Probleme mit dem Stufenschalter, interne \u00dcberschl\u00e4ge und lose Leiter im elektrischen Transformator.<\/p>\r\n\r\n\r\n\r\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Cellulose_Insulation_Degradation\"><\/span>Zersetzung von Zellulosed\u00e4mmung<span class=\"ez-toc-section-end\"><\/span><\/h3>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\">In elektrischen Transformatoren kommen verschiedene Arten von Isoliermaterialien zum Einsatz, und die Papierisolierung zersetzt sich anders als Mineral\u00f6l. Bei der Zersetzung der Papierisolierung entstehen im Transformator\u00f6l Kohlenmonoxid und Kohlendioxid. Hohe Kohlenmonoxidwerte deuten in der Regel auf einen fortschreitenden Isolationsverfall im Transformator hin.<\/p>\r\n\r\n\r\n\r\n\r\n\r\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Factors_Affecting_DGA_Accuracy\"><\/span>Faktoren, die die Genauigkeit der DGA beeinflussen<span class=\"ez-toc-section-end\"><\/span><\/h2>\r\n\r\n\r\n\r\n<ul class=\"wp-block-list\">\r\n<li>Eine unsachgem\u00e4\u00dfe Probenahme des \u00d6ls, an dem die Analyse der gel\u00f6sten Gase durchgef\u00fchrt werden soll, kann zu fehlerhaften Ergebnissen f\u00fchren. In den meisten F\u00e4llen ist es die Verunreinigung durch Luft, die bei der \u00d6lprobenahme auftritt, die zu fehlerhaften Ergebnissen f\u00fchrt.<\/li>\r\n\r\n\r\n\r\n<li>Das oxidierte Transformator\u00f6l kann das Gasbildungsverhalten beeinflussen und somit die Ergebnisse der Analyse der gel\u00f6sten Gase ver\u00e4ndern.<\/li>\r\n\r\n\r\n\r\n<li>Die hohe Belastung des Transformators kann die Gasbildung im Transformator\u00f6l verst\u00e4rken, was sich zun\u00e4chst in den DGA-Ergebnissen niederschl\u00e4gt.<\/li>\r\n\r\n\r\n\r\n<li>Wenn der elektrische Transformator weiterhin bei einer hohen Betriebstemperatur betrieben wird, kann dies die Zersetzung des Transformator\u00f6ls und des Isoliermaterials beschleunigen, was sich zun\u00e4chst auf die Ergebnisse der Gel\u00f6stgasanalyse auswirkt.<\/li>\r\n\r\n\r\n\r\n<li>Um die Ergebnisse der Analyse gel\u00f6ster Gase optimal nutzen zu k\u00f6nnen, muss die Untersuchung in regelm\u00e4\u00dfigen Abst\u00e4nden durchgef\u00fchrt werden; zu lange oder zu kurze Abst\u00e4nde k\u00f6nnen die Zuverl\u00e4ssigkeit des Ergebnisses beeintr\u00e4chtigen.<\/li>\r\n<\/ul>\r\n\r\n\r\n\r\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Advantages_of_Gas_Chromatography\"><\/span>Vorteile der Gaschromatographie<span class=\"ez-toc-section-end\"><\/span><\/h2>\r\n\r\n\r\n\r\n<ul class=\"wp-block-list\">\r\n<li>Die Gaschromatographie ist eine vollst\u00e4ndig zerst\u00f6rungsfreie Pr\u00fcfmethode, was bedeutet, dass das Produkt vor und nach der Pr\u00fcfung unver\u00e4ndert bleibt.<\/li>\r\n\r\n\r\n\r\n<li>Die Gaschromatographie bietet eine sehr hohe Messgenauigkeit hinsichtlich der Endkonzentration von Gasen im Transformator\u00f6l.<\/li>\r\n\r\n\r\n\r\n<li>Die Gaschromatographie erm\u00f6glicht eine sehr fr\u00fchzeitige Fehlererkennung in elektrischen Transformatoren, wodurch lange Ausfallzeiten vermieden werden.<\/li>\r\n\r\n\r\n\r\n<li>Mit der Gaschromatographie lassen sich mithilfe desselben Verfahrens verschiedene Fehlerarten nachweisen.<\/li>\r\n\r\n\r\n\r\n<li>Dieser Prozess tr\u00e4gt dazu bei, den Aufwand f\u00fcr die vorausschauende Wartung zu verringern und unerwartete Transformatorausf\u00e4lle zu vermeiden.<\/li>\r\n\r\n\r\n\r\n<li>Die Gaschromatographie tr\u00e4gt dazu bei, die Lebensdauer von elektrischen Transformatoren zu verl\u00e4ngern und die Wartungskosten zu minimieren.<\/li>\r\n\r\n\r\n\r\n<li>Alle oben genannten Punkte lassen sich unter einem Aspekt zusammenfassen: Die Gaschromatographie tr\u00e4gt zur Verbesserung der Systemzuverl\u00e4ssigkeit bei.<\/li>\r\n<\/ul>\r\n\r\n\r\n\r\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Limitations_of_Gas_Chromatography\"><\/span>Einschr\u00e4nkungen der Gaschromatographie<span class=\"ez-toc-section-end\"><\/span><\/h2>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\">Obwohl die Gaschromatographie ein wirksames Verfahren zur Ermittlung von Fehlern in einem Transformator ist, hat sie doch ihre Grenzen.<\/p>\r\n\r\n\r\n\r\n<ul class=\"wp-block-list\">\r\n<li>F\u00fcr diesen Prozess sind spezielle Ger\u00e4te und ein Labor erforderlich, um die Arbeiten durchzuf\u00fchren.<\/li>\r\n\r\n\r\n\r\n<li>Nach Abschluss des Prozesses ist eine erfahrene und hochqualifizierte Person erforderlich, um die Analyse zu verstehen und die endg\u00fcltige Entscheidung zu treffen.<\/li>\r\n\r\n\r\n\r\n<li>Wenn mehrere Verwerfungen gleichzeitig auftreten, k\u00f6nnen sich die Gasverteilungsmuster \u00fcberschneiden.<\/li>\r\n\r\n\r\n\r\n<li>Stichprobenfehler k\u00f6nnen das Ergebnis leicht verf\u00e4lschen.<\/li>\r\n<\/ul>\r\n\r\n\r\n\r\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"FAQ\"><\/span><span id=\"FAQ\" class=\"ez-toc-section\"><\/span><strong>H\u00e4ufig gestellte Fragen<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\r\n\r\n\r\n\r\n<div class=\"saswp-faq-block-section\">\r\n<ol style=\"list-style-type: none;\">\r\n<li style=\"list-style-type: none;\">\r\n<h5 class=\"saswp-faq-question-title\"><span class=\"ez-toc-section\" id=\"What_Is_the_IEC_Standard_For_DGA_Analysis\"><\/span><span id=\"What_Is_the_IEC_Standard_For_DGA_Analysis\" class=\"ez-toc-section\"><\/span><strong>Wie lautet die IEC-Norm f\u00fcr die DGA-Analyse?<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h5>\r\n<p class=\"saswp-faq-answer-text\">Die Norm IEC 60599 der Internationalen Elektrotechnischen Kommission (IEC) enth\u00e4lt die erforderlichen Informationen zur Auswertung von DGA-Analysen und zu den normativen Grenzwerten.<\/p>\r\n<\/li>\r\n<li style=\"list-style-type: none;\">\r\n<h5 class=\"saswp-faq-question-title\"><span class=\"ez-toc-section\" id=\"What_Is_IEEE_Standard_For_Electrical_Transformer_DGA\"><\/span><span id=\"What_Is_IEEE_Standard_For_Electrical_Transformer_DGA\" class=\"ez-toc-section\"><\/span><strong>Was ist die IEEE-Norm f\u00fcr die Gasanalyse (DGA) bei elektrischen Transformatoren?<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h5>\r\n<p class=\"saswp-faq-answer-text\">IEEE C57.104 ist eine verbindliche Norm, die Informationen zur Interpretation der Ergebnisse der DGA-Analyse von elektrischen Transformatoren enth\u00e4lt.<\/p>\r\n<\/li>\r\n<li style=\"list-style-type: none;\">\r\n<h5 class=\"saswp-faq-question-title\"><span class=\"ez-toc-section\" id=\"How_Do_I_Interpret_DGA_Analysis_Results\"><\/span><span id=\"How_Do_I_Interpret_DGA_Analysis_Results\" class=\"ez-toc-section\"><\/span><strong>Wie interpretiere ich die Ergebnisse einer DGA-Analyse?<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h5>\r\n<p class=\"saswp-faq-answer-text\">Es erfordert viel Erfahrung, um die Ergebnisse der Gasanalyse eines Transformators zu verstehen. Bei der Auswertung der Ergebnisse m\u00fcssen die Herstellerempfehlungen zur Durchf\u00fchrung der Pr\u00fcfung sowie internationale Normen ber\u00fccksichtigt werden.<\/p>\r\n<\/li>\r\n<\/ol>\r\n<\/div>\r\n\r\n\r\n\r\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-block-buttons-is-layout-flex wp-container-core-buttons-is-layout-3e41869c\">\r\n<div class=\"wp-block-button quoteModal\"><a class=\"wp-block-button__link wp-element-button\">Jetzt ein Angebot anfordern<\/a><\/div>\r\n<\/div>\r\n\r\n\r\n\r\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Conclusion\"><\/span>Fazit<span class=\"ez-toc-section-end\"><\/span><\/h2>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\">Die Gaschromatographie wird durchgef\u00fchrt, um die Analyse der gel\u00f6sten Gase in gro\u00dfen Transformatoren zu erhalten. Bei diesem Verfahren wird eine Transformator\u00f6lprobe aus dem Transformator entnommen und analysiert, um umfassende Informationen \u00fcber die verschiedenen darin gel\u00f6sten Gase sowie die genaue Menge jedes Gases zu erhalten. Daelim Transformers f\u00fchrt diese Analyse bei jedem einzelnen Transformator durch, um sicherzustellen, dass diese den internationalen Normen wie IEEE, ANSI, CSA, IEC und anderen entsprechen. Wenn Sie Fragen zu Gro\u00dftransformatoren haben, <a href=\"https:\/\/www.daelimtransformer.com\/de\/contact-us\/\">Kontaktieren Sie uns<\/a>.<\/p>\r\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-12960\" src=\"https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/06\/daelim-transformer-heavy-duty-transformer-factory.webp\" alt=\"daelim transformer schwerer Transformator Fabrik\" width=\"1398\" height=\"600\" srcset=\"https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/06\/daelim-transformer-heavy-duty-transformer-factory.webp 1398w, https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/06\/daelim-transformer-heavy-duty-transformer-factory-768x330.webp 768w, https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/06\/daelim-transformer-heavy-duty-transformer-factory-18x8.webp 18w, https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/06\/daelim-transformer-heavy-duty-transformer-factory-600x258.webp 600w\" sizes=\"(max-width: 1398px) 100vw, 1398px\" \/><\/p>\r\n\r\n<p>&nbsp;<\/p>","protected":false},"excerpt":{"rendered":"<p>The large electrical transformers are one of the most valuable and critical assets in any electricity distribution system. The system relies on them so much that any fault or problem in these large power transformers can seriously affect the stability and efficiency of the system. This article will provide a very comprehensive analysis of large [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":13777,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[279],"tags":[],"class_list":["post-7622","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articles-news"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/posts\/7622","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/comments?post=7622"}],"version-history":[{"count":6,"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/posts\/7622\/revisions"}],"predecessor-version":[{"id":13782,"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/posts\/7622\/revisions\/13782"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/media\/13777"}],"wp:attachment":[{"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/media?parent=7622"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/categories?post=7622"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/tags?post=7622"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}