{"id":7808,"date":"2026-01-05T10:50:22","date_gmt":"2026-01-05T10:50:22","guid":{"rendered":"https:\/\/daelimtransformer.com\/?p=7808"},"modified":"2026-03-14T14:35:05","modified_gmt":"2026-03-14T14:35:05","slug":"how-to-check-transformer-primary-and-secondary","status":"publish","type":"post","link":"https:\/\/www.daelimtransformer.com\/de\/how-to-check-transformer-primary-and-secondary.html","title":{"rendered":"\/ Wie \u00fcberpr\u00fcft man den Prim\u00e4r- und Sekund\u00e4rwickel eines Transformators?"},"content":{"rendered":"<div id=\"contentMain\" class=\"article-content\">\n<div class=\"row\">\n<div class=\"signleContent col-lg-6 mb-3\"><img decoding=\"async\" class=\"img-fluid\" src=\"\/media\/115\/Transformer-Primary-And-Secondary.webp\" alt=\"Wie man den Prim\u00e4r- und Sekund\u00e4rtransformator \u00fcberpr\u00fcft\" \/><\/div>\n<div class=\"signleContent col-lg-6 mb-3\">\n<div class=\"line-height-22 mt-3 fs-16 text-dark\">\n<p class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><a href=\"https:\/\/www.daelimtransformer.com\/de\/electric-transformer-guide.html\"><u><span class=\"15\" style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #1155cc;\"><span style=\"text-decoration: underline;\"><span style=\"text-underline: single;\"><span style=\"font-style: normal;\">Elektrische Transformatoren<\/span><\/span><\/span><\/span><\/span><\/span><\/u><\/a><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #000000;\"><span style=\"font-style: normal;\"> regulieren den Strom f\u00fcr Ihre H\u00e4user und Industrien. Sie erh\u00f6hen oder senken ihn auf ein Niveau, das sicher verwendet werden kann. Transformatoren regulieren den Strom durch ihre Wicklungen, und Transformatorwicklungen sind nichts anderes als ein elektrisch leitender Draht, normalerweise Kupferdraht, der um ein metallisches Objekt, das als Kern bezeichnet wird, gewickelt ist.\u00a0\u00a0<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><a href=\"https:\/\/www.daelimtransformer.com\/de\/electrical-transformer.html\"><u><span class=\"15\" style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #1155cc;\"><span style=\"text-decoration: underline;\"><span style=\"text-underline: single;\"><span style=\"font-style: normal;\">Elektrische Transformatoren<\/span><\/span><\/span><\/span><\/span><\/span><\/u><\/a><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #000000;\"><span style=\"font-style: normal;\">\u00a0sind auch ein integraler Bestandteil fast aller elektrischen Ger\u00e4te, und ein Ausfall des Transformators bedeutet einen Ausfall des elektrischen Ger\u00e4ts. Daher ist die Frage, wie man die Prim\u00e4r- und Sekund\u00e4rwicklungen eines Transformators \u00fcberpr\u00fcft, eine wichtige Frage f\u00fcr jeden Elektriker.<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p><a class=\"btn btn-primary mt-1 font-weight-bold fs-16 pageBtn quoteModal\">Kontaktieren Sie Daelim Transformer<\/a><\/p>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"row\">\n<div class=\"col-lg-12 article-content\">\n<p><a id=\"mdnTags0\" class=\"mdnTags\" name=\"mdn0\" data-index=\"0\"><\/a><\/p>\n<h2 style=\"margin-top: 16px; margin-bottom: 13px; text-align: left;\"><span class=\"ez-toc-section\" id=\"Tools_and_Equipment_Needed_To_Check_Transformer_Winding\"><\/span>Werkzeuge und Ausr\u00fcstung, die zur \u00dcberpr\u00fcfung von Transformatorwicklungen ben\u00f6tigt werden<img decoding=\"async\" style=\"width: 400px; height: 271px; float: right;\" title=\"Transformatorenwicklung\" src=\"\/media\/115\/transformer-winding.webp\" alt=\"Transformatorenwicklung\" \/><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><a href=\"https:\/\/www.daelimtransformer.com\/de\/understanding-types-of-transformer-winding-and-their-applications.html\">Transformatorwicklungen<\/a>\u00a0sind ein sehr einfach gestalteter Teil des Transformators und sie ben\u00f6tigen nicht viel, um \u00fcberpr\u00fcft und inspiziert zu werden. Sie ben\u00f6tigen lediglich ein<\/p>\n<ul>\n<li>Multimeter, um die Spannungs- und Stromwerte \u00fcber der Wicklung zu \u00fcberpr\u00fcfen.<\/li>\n<li>Isolationswiderstandsmesser, um den Isolationswiderstand zwischen den Wicklungsschichten zu messen.<\/li>\n<li>Sicherheitsausr\u00fcstung wie elektrisch isolierte Handschuhe und klare, harte Kunststoffschutzbrillen, um sich w\u00e4hrend der Arbeit zu sch\u00fctzen.<\/li>\n<\/ul>\n<p><a id=\"mdnTags1\" class=\"mdnTags\" name=\"mdn1\" data-index=\"1\"><\/a><\/p>\n<h2><span class=\"ez-toc-section\" id=\"Safety_Precautions_Before_Checking_Winding\"><\/span>Sicherheitsvorkehrungen vor der \u00dcberpr\u00fcfung der Wicklungen<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Ihre Sicherheit hat oberste Priorit\u00e4t, gefolgt von der Sicherheit der Ausr\u00fcstung und der Umgebung. F\u00fchren Sie den Prozess daher nur aus, wenn Sie \u00fcber umfassende Kenntnisse zur \u00dcberpr\u00fcfung der Prim\u00e4r- und Sekund\u00e4rwicklungen des Transformators verf\u00fcgen und alle notwendigen Werkzeuge haben. Achten Sie darauf, die folgenden Punkte zu \u00fcberpr\u00fcfen, bevor Sie mit der \u00dcberpr\u00fcfung der Transformatorwicklung beginnen.<\/p>\n<p>Zuerst trennen Sie den Transformator von seiner Stromquelle. Dies beseitigt das Risiko von versehentlichen elektrischen Schl\u00e4gen oder Ger\u00e4ten Sch\u00e4den w\u00e4hrend des Pr\u00fcfprozesses.<\/p>\n<p>Zweitens f\u00fchren Sie eine Spannungspr\u00fcfung mit einem Multimeter durch. Verwenden Sie ein Standard-Multimeter und \u00fcberpr\u00fcfen Sie jeden Eingang- und Ausgangsanschluss des Transformators. An jedem der Anschl\u00fcsse sollte eine Spannungsanzeige von Null vorhanden sein.<\/p>\n<p>Drittens stellen Sie sicher, dass die Erdung ordnungsgem\u00e4\u00df erfolgt. Egal, ob Sie die Wicklung entfernen oder sie im Transformator zur \u00dcberpr\u00fcfung belassen, achten Sie darauf, dass die Wicklung oder der Transformator ordnungsgem\u00e4\u00df geerdet ist. Die Erdung leitet Streustr\u00f6me von Personen ab und verringert das Risiko von Unf\u00e4llen.<\/p>\n<p>Viertens ber\u00fchren Sie Transformatorenbestandteile niemals ohne entsprechendes Wissen. Vermeiden Sie alle Arten von unn\u00f6tigen Ber\u00fchrungen aller Transformatorenbestandteile, insbesondere von unter Spannung stehenden Teilen. Selbst wenn der Strom abgeschaltet ist, k\u00f6nnen einige Teile eine Restladung behalten oder kapazitive Effekte haben. Behandeln Sie elektrische Ger\u00e4te immer mit Vorsicht und verwenden Sie isolierte Werkzeuge f\u00fcr zus\u00e4tzliche Sicherheit.<\/p>\n<p><a id=\"mdnTags2\" class=\"mdnTags\" name=\"mdn2\" data-index=\"2\"><\/a><\/p>\n<h2><span class=\"ez-toc-section\" id=\"How_To_Identify_Primary_And_Secondary_Of_Transformer\"><\/span>Wie identifiziert man Prim\u00e4r- und Sekund\u00e4rwickel eines Transformators?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><a href=\"https:\/\/www.daelimtransformer.com\/de\/1000-kva-power-transformer-13800v-delta-primary-600grdy-347-secondary-knan-ansi-grey.html\"><img decoding=\"async\" style=\"width: 350px; height: 350px; float: right;\" title=\"1000-kVA-Power-Transformer-13800V-Delta-Primary-600GrdY-347-Secondary\" src=\"\/media\/115\/1000-kVA-Power-Transformer-13800V-Delta-Primary-600GrdY-347-Secondary.webp\" alt=\"1000-kVA-Power-Transformer-13800V-Delta-Primary-600GrdY-347-Secondary\" \/><\/a>Die prim\u00e4re und sekund\u00e4re Wicklung des Transformators kann auf verschiedene Weise identifiziert werden. Der einfachste und authentischste Weg, dies zu \u00fcberpr\u00fcfen, besteht darin, das Typenschild zu \u00fcberpr\u00fcfen, das an der Wicklung angebracht ist. Die meisten Hersteller haben ein Typenschild f\u00fcr die prim\u00e4re oder Eingangswicklung und ein weiteres f\u00fcr die sekund\u00e4re oder Ausgangswicklung des Transformators angebracht.<\/p>\n<p>Wenn Ihre Transformatorenwicklung noch mit dem Transformator verbunden ist, beobachten Sie, welche Wicklung mit der Stromquelle verbunden ist; diese wird die prim\u00e4re Wicklung sein und die andere die sekund\u00e4re Wicklung.<\/p>\n<p>Wenn Sie eine Wicklung von einem Transformatorschritt-Down-Transformator haben, was in den meisten F\u00e4llen bei Haushaltsger\u00e4ten und Installationen der Fall ist, dann wird die prim\u00e4re Wicklung gr\u00f6\u00dfer sein als die sekund\u00e4re Wicklung. Wenn Sie den Widerstand mit einem Multimeter \u00fcberpr\u00fcfen, wird der Widerstand der prim\u00e4ren Wicklung h\u00f6her sein als der der sekund\u00e4ren Wicklung, da die prim\u00e4re Wicklung mehr Drahtwindungen hat als die sekund\u00e4re.<\/p>\n<p><a id=\"mdnTags3\" class=\"mdnTags\" name=\"mdn3\" data-index=\"3\"><\/a><\/p>\n<h2><span class=\"ez-toc-section\" id=\"How_To_Check_Transformer_Primary_And_Secondary_With_Multimeter\"><\/span>Wie \u00fcberpr\u00fcft man den Prim\u00e4r- und Sekund\u00e4rwickel eines Transformators mit einem Multimeter?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Die \u00dcberpr\u00fcfung der prim\u00e4ren und sekund\u00e4ren Wicklung des Transformators mit einem Multimeter ist sehr einfach und erfordert die folgenden Schritte. Stellen Sie zun\u00e4chst sicher, dass Sie alle oben genannten Sicherheitsma\u00dfnahmen getroffen haben.<\/p>\n<ul>\n<li>Der erste Schritt besteht darin, das Multimeter auf den Widerstands- oder Durchgangsmodus einzustellen. Je nach Art Ihres Multimeters m\u00fcssen Sie entweder den Auswahlknopf drehen oder die rote Klemme in den Widerstandssteckplatz einsetzen.<\/li>\n<li>Vergewissern Sie sich, dass die Transformatorenwicklung nicht mit einer Stromquelle verbunden ist.<\/li>\n<li>Legen Sie die Klemmen des Multimeters auf die Klemmen der Wicklung. Es spielt keine Rolle, welche Klemme mit welcher Klemme der Wicklung verbunden ist. Nur eine Klemme des Multimeters, eine Klemme der Wicklung und die andere mit der anderen Klemme.<\/li>\n<li>Wenn Sie den Durchgangsmodus ausgew\u00e4hlt haben, dann ist ein Beep des Multimeters ein Hinweis darauf, dass der Wicklungsstromkreis geschlossen ist.<\/li>\n<li>Wenn Sie den Widerstandsmodus ausgew\u00e4hlt haben, beobachten Sie den Widerstandslesewert, den Sie auf dem Multimeter sehen.<\/li>\n<li>Eine funktionierende prim\u00e4re oder sekund\u00e4re Wicklung zeigt einen mittleren Widerstandswert, abh\u00e4ngig von ihrem Design.<\/li>\n<li>Wenn der Multimeter-Bildschirm einen unendlichen Widerstandswert anzeigt, dann hat die Wicklung einen gebrochenen Draht, einen offenen Stromkreis und muss repariert werden.<\/li>\n<li>Wenn ein Multimeter-Bildschirm einen sehr niedrigen Widerstand, also einen Widerstand nahe Null, anzeigt, dann hat die Wicklung einen Kurzschluss.<\/li>\n<\/ul>\n<h2><a id=\"mdnTags4\" name=\"mdn4\" data-index=\"4\"><\/a><\/h2>\n<h2><span class=\"ez-toc-section\" id=\"Advanced_Techniques_for_Transformer_Testing\"><\/span>Fortgeschrittene Techniken zur Transformatorpr\u00fcfung<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><a id=\"mdnTags5\" class=\"mdnTags\" name=\"mdn5\" data-index=\"5\"><\/a><\/p>\n<h3><span class=\"ez-toc-section\" id=\"Insulation_Resistance_Test\"><\/span>Isolationswiderstandstest<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p class=\"p\" style=\"margin-top: 16px; margin-bottom: 13px; text-align: left;\"><img decoding=\"async\" style=\"width: 400px; height: 303px; float: right;\" title=\"Transformatorpr\u00fcfung\" src=\"\/media\/115\/5000-kva-transformer-testing.webp\" alt=\"Transformatorpr\u00fcfung\" \/>Der Isolationswiderstandstest wird durchgef\u00fchrt, um die Isolation zwischen den Wicklungen und zwischen Wicklung und Kern zu \u00fcberpr\u00fcfen. Dies ist ein entscheidender Test, der sicherstellt, ob die Wicklungen funktionst\u00fcchtig sind oder repariert werden m\u00fcssen. Um einen Isolationswiderstandstest durchzuf\u00fchren, befolgen Sie die unten genannten Schritte.<\/p>\n<ul>\n<li>Stellen Sie zun\u00e4chst sicher, dass der Transformator nicht mit der Stromquelle verbunden ist.<\/li>\n<li>Vergewissern Sie sich, dass alle Klemmen der Wicklung von Staub, \u00d6l oder Fett befreit sind.<\/li>\n<li>Stellen Sie sicher, dass der Isolationspr\u00fcfer ordnungsgem\u00e4\u00df funktioniert und seine Klemmen gereinigt sind.<\/li>\n<li>Um die Isolierung zwischen einer der Wicklungen und dem Kern zu \u00fcberpr\u00fcfen.<\/li>\n<li>Nehmen Sie einen Isolationspr\u00fcfer, auch bekannt als Megohmmeter, und verbinden Sie einen seiner Anschl\u00fcsse mit dem Anschluss der Wicklung, die Sie \u00fcberpr\u00fcfen m\u00f6chten.<\/li>\n<li>Verbinden Sie den anderen Anschluss des Messger\u00e4ts entweder mit dem Kern oder dem Erdungspunkt.<\/li>\n<li>Um inter-Wicklungs-Isolationspr\u00fcfungen durchzuf\u00fchren, verbinden Sie die Sonden zwischen verschiedenen Wicklungsanschl\u00fcssen (z. B. prim\u00e4r zu sekund\u00e4r).<\/li>\n<li>Stellen Sie jetzt die Spannung des Messger\u00e4ts gem\u00e4\u00df der Transformator-Spezifikation ein.<\/li>\n<li>Beginnen Sie den Test, indem Sie die spezifische Spannung f\u00fcr eine feste Dauer anwenden, die eine Minute betr\u00e4gt.<\/li>\n<li>Das Megohmmeter zeigt den Widerstand zwischen den ausgew\u00e4hlten zwei Verbindungen an.<\/li>\n<li>Der Wert dieses Widerstands liegt im Bereich von Megaohm und sollte \u00fcber den vom Hersteller festgelegten minimalen akzeptablen Isolationswiderstandswerten liegen.<\/li>\n<li>Ein Widerstandswert im Bereich von Hunderten von Megohm zeigt eine gesunde Isolierung mit minimalem Stromleck an. Dies deutet darauf hin, dass die Isolierung trocken, intakt und in der Lage ist, die angelegte Spannung zu withstanden.<\/li>\n<li>Ein niedriger Widerstandswert (z. B. unter 1 M\u03a9) weist auf potenzielle Probleme hin, wie z. B. Feuchtigkeitseintritt oder Kontamination.<\/li>\n<\/ul>\n<p>Mehr Ressourcen:\u00a0<a href=\"https:\/\/www.daelimtransformer.com\/de\/test-of-power-transformer.html\">Wie testet man einen Leistungstransformator?<\/a><\/p>\n<p><a id=\"mdnTags6\" name=\"mdn6\" data-index=\"6\"><\/a><\/p>\n<h3><span class=\"ez-toc-section\" id=\"Testing_for_Winding_Polarity\"><\/span>\u00dcberpr\u00fcfung der Wicklungspolarit\u00e4t<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Die Pr\u00fcfung der Wicklungs-Polarit\u00e4t des Transformators ist wichtig, um die Phasenbeziehung zwischen der prim\u00e4ren und der sekund\u00e4ren Wicklung zu \u00fcberpr\u00fcfen. Die Wicklungen k\u00f6nnen entweder in Phase oder au\u00dfer Phase zueinander sein, und nur eine phasenkoh\u00e4rente Beziehung zwischen den Wicklungen ist erforderlich.<\/p>\n<p>Befolgen Sie die folgenden Schritte, um die Wicklungs-Polarit\u00e4t des Transformators zu \u00fcberpr\u00fcfen.<\/p>\n<ul>\n<li>Zuerst stellen Sie sicher, dass der Transformator und seine Wicklungen von allen Stromquellen getrennt sind.<\/li>\n<li>Bezeichnen Sie die Anschl\u00fcsse der Wicklung, benennen Sie P1 und P2 f\u00fcr die beiden Anschl\u00fcsse der Wicklung und S1 und S2 f\u00fcr die beiden Anschl\u00fcsse der sekund\u00e4ren Wicklung.<\/li>\n<li>Stellen Sie das Multimeter auf Spannungsmessung ein.<\/li>\n<li>Wenden Sie jetzt eine niedrige Wechselspannung an die beiden Anschl\u00fcsse der prim\u00e4ren Wicklung an.<\/li>\n<li>Benutzen Sie nun ein Multimeter, um die Spannung sowohl an der prim\u00e4ren Wicklung als auch an der sekund\u00e4ren Wicklung zu messen. Um die Spannung zu messen, schlie\u00dfen Sie ein Voltmeter parallel zu den Wicklungsanschl\u00fcssen an. Schlie\u00dfen Sie es niemals in Serie an, um die Spannung zu messen.<\/li>\n<li>Notieren Sie die Spannung der prim\u00e4ren und sekund\u00e4ren Wicklung.<\/li>\n<li>Sie m\u00fcssen auch die kombinierte Spannung der Transformatorwicklungen messen. Um dies zu messen, verbinden Sie einen roten Anschluss mit dem Eingangsanschluss an der prim\u00e4ren Wicklung, sagen wir P1, und den schwarzen Anschluss mit dem Ausgangsanschluss der sekund\u00e4ren Wicklung, sagen wir S2.<\/li>\n<li>Notieren Sie die kombinierte Wicklungsspannung.<\/li>\n<li>Wenn die kombinierte Spannung der Wicklung gleich der Summe der Prim\u00e4r- und Sekund\u00e4rspannung ist, dann sind Ihre Transformatorwicklungen in Phase.<\/li>\n<li>Wenn die kombinierte Spannung der Wicklung gleich der Differenz der Prim\u00e4r- und Sekund\u00e4rspannung ist, dann sind Ihre Transformatorwicklungen au\u00dfer Phase.<\/li>\n<\/ul>\n<p><a id=\"mdnTags7\" class=\"mdnTags\" name=\"mdn7\" data-index=\"7\"><\/a><\/p>\n<h2><span class=\"ez-toc-section\" id=\"Importance_of_Checking_Transformer_Windings\"><\/span>Bedeutung der \u00dcberpr\u00fcfung von Transformatorwicklungen<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p class=\"p\" style=\"margin-bottom: 13px; text-align: left;\"><a href=\"https:\/\/www.daelimtransformer.com\/de\/contact.html\"><img decoding=\"async\" style=\"width: 340px; height: 340px; float: right;\" title=\"Auf Pad montierte Transformatorwicklung\" src=\"\/media\/115\/44kv-pad-mounted-transformer-winding.webp\" alt=\"Auf Pad montierte Transformatorwicklung\" \/><\/a>Da Transformatoren als R\u00fcckgrat unserer elektrischen Systeme fungieren und deren Ausfall um jeden Preis verhindert werden muss. Die \u00dcberpr\u00fcfung der Transformatorwicklungen bietet folgende Vorteile.<\/p>\n<ul>\n<li>Die kontinuierliche \u00dcberpr\u00fcfung der Transformatorwicklungen hilft, Probleme in fr\u00fchen Stadien zu erkennen und zu beseitigen, wodurch die Zuverl\u00e4ssigkeit in der Leistung und den Betrieb gew\u00e4hrleistet wird.<\/li>\n<li>Das Ansprechen auf alle Probleme in fr\u00fchen Stadien verhindert katastrophale Ausf\u00e4lle des Transformators oder Explosionen des Transformators, die gef\u00e4hrlich f\u00fcr die Umgebung und die angeschlossenen Ger\u00e4te sein k\u00f6nnen.<\/li>\n<li>Die kontinuierliche \u00dcberpr\u00fcfung der Transformatorwicklungen erh\u00f6ht die Sicherheit und reduziert das Risiko von Gefahren wie elektrischen Schl\u00e4gen, Br\u00e4nden und Kurzschl\u00fcssen zwischen den Wicklungen.<\/li>\n<li>Die regelm\u00e4\u00dfige \u00dcberwachung und Wartung der Transformatorwicklungen verl\u00e4ngert deren Lebensdauer, sch\u00fctzt Ihre Investition und vermeidet die Notwendigkeit h\u00e4ufiger Ersatzteile.<\/li>\n<\/ul>\n<p><a id=\"mdnTags8\" class=\"mdnTags\" name=\"mdn8\" data-index=\"8\"><\/a><\/p>\n<h2><span class=\"ez-toc-section\" id=\"Conclusion\"><\/span>Fazit<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Transformatoren sind lebenswichtige Komponenten elektrischer Systeme. Ihre regelm\u00e4\u00dfigen Wicklungs\u00fcberpr\u00fcfungen gew\u00e4hrleisten deren Zuverl\u00e4ssigkeit, Sicherheit und Langlebigkeit. Mithilfe von Werkzeugen wie einem Multimeter und einem Isolationspr\u00fcfer k\u00f6nnen Probleme wie Unterbrechungen, Kurzschl\u00fcsse oder Isolationsdurchbr\u00fcche diagnostiziert werden. Eine ordnungsgem\u00e4\u00dfe Wartung verhindert katastrophale Ausf\u00e4lle, verbessert die Betriebssicherheit und verl\u00e4ngert die Lebensdauer des Transformators.<\/p>\n<p><a id=\"mdnTags9\" name=\"mdn9\" data-index=\"9\"><\/a><\/p>\n<h2><span class=\"ez-toc-section\" id=\"Follow_Up\"><\/span>Nachverfolgung<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Wicklungen sind der wichtigste Teil des Transformators und ben\u00f6tigen kontinuierliche Inspektion und Wartung. Dealim bietet Transformatorwicklungen aller Art, Gr\u00f6\u00dfe und Kapazit\u00e4t in bester Qualit\u00e4t an, unter Beachtung von Standards wie ANSI, IEEE, CSA, AS, GOST, IEC, EU und DIN\/VDE.<\/p>\n<p>Wir haben voll funktionsf\u00e4hige Vertriebs- und Dienstleistungszentren sowie eine starke Kundenbasis in den USA, Europa, Kanada, Australien und \u00fcberall auf der Welt. Wenn Sie eine Anfrage zu Transformatoren haben, dann <a href=\"https:\/\/www.daelimtransformer.com\/de\/contact.html\">Kontaktieren Sie uns<\/a> und wir werden Sie durch den Prozess f\u00fchren.<\/p>\n<\/div>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Electric transformers regulate electricity for your homes and industries. They either step it up or step it down to the level that it is safe for use. Transformers regulate electricity through their winding and transformer windings are nothing more than an electrically conductor wire, usually copper wire, wound around a metallic object called core.\u00a0\u00a0 Electrical [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":7809,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[279],"tags":[],"class_list":["post-7808","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articles-news"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/posts\/7808","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/comments?post=7808"}],"version-history":[{"count":0,"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/posts\/7808\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/media\/7809"}],"wp:attachment":[{"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/media?parent=7808"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/categories?post=7808"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/tags?post=7808"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}