{"id":8209,"date":"2026-01-07T06:50:14","date_gmt":"2026-01-07T06:50:14","guid":{"rendered":"https:\/\/daelimtransformer.com\/?p=8209"},"modified":"2026-03-04T09:14:34","modified_gmt":"2026-03-04T09:14:34","slug":"pad-mounted-transformer-for-bess-system-4-0-mva-in-riverside-county-california","status":"publish","type":"post","link":"https:\/\/www.daelimtransformer.com\/de\/pad-mounted-transformer-for-bess-system-40-mva-in-california.html","title":{"rendered":"Fu\u00dfmontierter Transformator f\u00fcr BESS-System 4,0 MVA in Riverside County, Kalifornien"},"content":{"rendered":"<div class=\"article-content\" id=\"contentMain\" uia-uid=\"0|1\">\n<div class=\"row\">\n<div class=\"signleContent col-lg-6 mb-3\">\n<img decoding=\"async\" class=\"img-fluid\" src=\"\/media\/115\/Pad-Mounted-Transformer-for-BESS-System-4-MVA.webp\" alt=\"Pad-montierter Transformator f\u00fcr BESS-System\"><\/p><\/div>\n<div class=\"signleContent col-lg-6 mb-3\">\n<div class=\"line-height-22 mt-3 fs-16 text-dark\">\n<p style=\"text-align:justify\"><span style=\"color:#000000;\"><span style=\"font-size:18px;\">Heute pr\u00e4sentiert Daelim Transformator stolz einen pad-montierten Transformator f\u00fcr ein 4,0 MVA Batteriespeichersystem (BESS), das im Riverside County, Kalifornien, angesiedelt ist.<\/span><\/span><\/p>\n<p><span style=\"color:#000000;\"><span style=\"font-size:18px;\">Dieser pad-montierte Transformator ist speziell f\u00fcr den Einsatz in einer Energieerzeugungsanlage f\u00fcr Batteriespeicher konzipiert. Sein robustes Design ist darauf ausgelegt, harmonische Spannungen und Str\u00f6me, die von Wechselrichtern ausgehen, transiente \u00dcberspannungen, die durch Schaltvorg\u00e4nge und Fehler verursacht werden, sowie die erheblichen Variationen der Transformatorlast, die h\u00e4ufig in BESS-Projekten auftreten, zu widerstehen. Der Transformator ist sorgf\u00e4ltig gefertigt, um den im kalifornischen Electrical Code Artikel 450 festgelegten Spezifikationen zu entsprechen.<\/span><\/span><\/p>\n<p>                                                        <a class=\"btn btn-primary mt-1 font-weight-bold fs-16 pageBtn quoteModal\" href=\"javascript:0;\">Kontaktieren Sie Daelim Transformer<\/a><\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"row\">\n<div class=\"col-lg-12\">\n<div class=\"d-flex align-items-center mb-3 mt-5\">\n<div class=\"d-inline-block w-100 mb-3 mr-auto ml-auto\">\n<div class=\"mb-0 fs-18 customTexts\">\n<p><span style=\"color:#000000;\"><span style=\"font-size:18px;\">In diesem Projekt wird der <\/span><\/span><span style=\"font-size:20px;\"><a href=\"https:\/\/www.daelimtransformer.com\/de\/three-phase-pad-mounted-transformer-daelim.html\" target=\"_blank\"><span style=\"color:#8e44ad;\">Pad montierter Transformator<\/span><\/a><\/span><span style=\"color:#000000;\"><span style=\"font-size:18px;\"> in einer Abw\u00e4rtskonfiguration eingesetzt, um seine Anpassungsf\u00e4higkeit und Effizienz innerhalb des Energiespeichersystems weiter zu verbessern. Daelim Transformator bleibt bestrebt, innovative L\u00f6sungen zu liefern, die den einzigartigen Anforderungen moderner Energiespeichereinrichtungen gerecht werden.<\/span><\/span><\/p>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"row mt-3 mb-2\">\n<div class=\"col-lg-4 mb-3\">\n                                                <img decoding=\"async\" class=\"img-fluid\" src=\"\/media\/115\/4-mva-pad-mounted-transformer-gauges.webp\" alt=\"BESS Transformatoranzeigen\"><\/p>\n<div class=\"text-4 mb-3 mt-2 index-title\">BESS Transformatoranzeigen<\/div>\n<div class=\"line-height-22 fs-16\" style=\"color:#666\"><\/div>\n<\/p><\/div>\n<div class=\"col-lg-4 mb-3\">\n                                                <img decoding=\"async\" class=\"img-fluid\" src=\"\/media\/115\/4-mva-pad-mounted-transformer-package.webp\" alt=\"BESS Transformatorpaket\"><\/p>\n<div class=\"text-4 mb-3 mt-2 index-title\">BESS Transformatorpaket<\/div>\n<div class=\"line-height-22 fs-16\" style=\"color:#666\"><\/div>\n<\/p><\/div>\n<div class=\"col-lg-4 mb-3\">\n                                                <img decoding=\"async\" class=\"img-fluid\" src=\"\/media\/115\/4-mva-pad-mounted-transformer-production.webp\" alt=\"BESS Transformatorproduktion\"><\/p>\n<div class=\"text-4 mb-3 mt-2 index-title\">BESS Transformatorproduktion<\/div>\n<div class=\"line-height-22 fs-16\" style=\"color:#666\"><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"row\">\n<div class=\"signleContent col-lg-6 mb-3\">\n<p>                                                    <img decoding=\"async\" class=\"img-fluid\" src=\"\/media\/115\/4-mva-pad-mounted-transformer.webp\" alt=\"Wichtige technische Spezifikationen\"><\/p><\/div>\n<div class=\"signleContent col-lg-6 mb-3\">\n<div class=\"line-height-22 mt-3 fs-16 text-dark\">\n<h2 style=\"text-align: justify;\"><span class=\"ez-toc-section\" id=\"Key_Technical_Specifications\"><\/span><span style=\"font-size:20px;\"><strong><span style=\"color:#000000;\">Wichtige technische Spezifikationen<\/span><\/strong><\/span><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<ul>\n<li><span style=\"color:#000000;\"><span style=\"font-size:16px;\">Transformator-Typ: Dreiphasen-Transformator \u2013 Pad-Mounted<\/span><\/span><\/li>\n<li><span style=\"color:#000000;\"><span style=\"font-size:16px;\">Leistung: 4000 kVA\uff084 MVA\uff09<\/span><\/span><\/li>\n<li><span style=\"color:#000000;\"><span style=\"font-size:16px;\">K\u00fchlklasse: ONAN (\u00d6l nat\u00fcrlich, Luft nat\u00fcrlich)<\/span><\/span><\/li>\n<li><span style=\"color:#000000;\"><span style=\"font-size:16px;\">\u00d6ltyp: Mineral\u00f6l<\/span><\/span><\/li>\n<li><span style=\"color:#000000;\"><span style=\"font-size:16px;\">Temperaturerh\u00f6hung: 65 \u00b0C (Hochw\u00e4rmekapazit\u00e4tspapier auf allen Wicklungen)<\/span><\/span><\/li>\n<li><span style=\"color:#000000;\"><span style=\"font-size:16px;\">Frequenz: 60 Hertz<\/span><\/span><\/li>\n<li><span style=\"color:#000000;\"><span style=\"font-size:16px;\">Nennspannungen:<\/span><\/span><\/li>\n<li><span style=\"color:#000000;\"><span style=\"font-size:16px;\">Prim\u00e4rspannungswicklung (H): 12,47 kV<\/span><\/span><\/li>\n<li><span style=\"color:#000000;\"><span style=\"font-size:16px;\">Sekund\u00e4rspannungswicklung (X): 34,5 kV<\/span><\/span><\/li>\n<li><span style=\"color:#000000;\"><span style=\"font-size:16px;\">Impedanz bei Nennkapazit\u00e4tsbewertung: 5,75%<\/span><\/span><\/li>\n<li><span style=\"color:#000000;\"><span style=\"font-size:16px;\">Betriebsbedingungen<\/span><\/span><\/li>\n<\/ul>\n<ol>\n<li><span style=\"color:#000000;\"><span style=\"font-size:16px;\">&nbsp;Umgebungstemperaturbereich -40 \u00b0C bis 50 \u00b0C<\/span><\/span><\/li>\n<li><span style=\"color:#000000;\"><span style=\"font-size:16px;\">H\u00f6henlage \u00fcber dem Meeresspiegel &lt;3.300 Fu\u00df<\/span><\/span><\/li>\n<\/ol>\n<p>                                                        <a class=\"btn btn-primary mt-1 font-weight-bold fs-16 pageBtn quoteModal\" href=\"javascript:0;\">Preis anfragen<\/a><\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"row\">\n<div class=\"col-lg-12\">\n<div class=\"d-flex align-items-center mb-3 mt-5\">\n<div class=\"d-inline-block w-100 mb-3 mr-auto ml-auto\">\n<div class=\"mb-0 fs-18 customTexts\">\n<h2 style=\"text-align: justify;\"><span class=\"ez-toc-section\" id=\"Daelim_Transformer_Solution\"><\/span><span style=\"color:#000000;\"><span style=\"font-size:20px;\"><strong>Daelim Transformatorl\u00f6sung<\/strong><\/span><\/span><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<h3><span class=\"ez-toc-section\" id=\"Features_and_Design_Highlights\"><\/span><span style=\"color:#000000;\"><strong><span style=\"font-size:18px;\">Merkmale und Design-H\u00f6hepunkte<\/span><\/strong><\/span><img decoding=\"async\" alt=\"4 MVA pad-montierter Transformator externe Abteile\" src=\"\/media\/115\/4-mva-pad-mounted-transformer-external-compartments.webp\" style=\"float: right; width: 306px; height: 235px;\" title=\"4 MVA pad-montierter Transformator externe Abteile\"><span class=\"ez-toc-section-end\"><\/span><\/h3>\n<ul>\n<li><span style=\"color:#000000;\"><span style=\"font-size:16px;\"><strong>Elektrostatisches Schutzschild: <\/strong>Unser Transformator ist so konzipiert, dass er harmonische Spannungen, transienten \u00dcberspannungen und dynamische Last\u00e4nderungen, die in BESS-Projekten auftreten, standh\u00e4lt und eine unterbrechungsfreie Stromversorgung gew\u00e4hrleistet.<\/span><\/span><\/li>\n<li><span style=\"color:#000000;\"><span style=\"font-size:16px;\"><strong>Vielseitiger Spannungsbetrieb:<\/strong> In der Lage, innerhalb eines Spannungsbereichs von +\/- 10% zu arbeiten, passt sich unser Transformator an variierende Energieanforderungen an und bietet Flexibilit\u00e4t und Effizienz.<\/span><\/span><\/li>\n<li><span style=\"color:#000000;\"><span style=\"font-size:16px;\"><strong>Abgriffwechsler:<\/strong> Befindet sich an der Hochspannungswicklung mit f\u00fcnf Abgriffen bei 2.5%.<\/span><\/span><\/li>\n<li><span style=\"color:#000000;\"><span style=\"font-size:16px;\"><strong>Externe F\u00e4cher:<\/strong> Ausgestattet mit einem Stickstofff\u00fcllstopfen, einem Thermometer im Ziffernblatt, einem Vakuum-\/Druckmesser, einem Fl\u00fcssigkeitsstandmesser und einem zug\u00e4nglichen \u00d6lstich-\/Entw\u00e4sserungsventil.<\/span><\/span><\/li>\n<li><span style=\"color:#000000;\"><span style=\"font-size:16px;\"><strong>T\u00fcren: <\/strong>Jeder Fachbereich verf\u00fcgt \u00fcber unabh\u00e4ngige, automatisch verriegelnde Drei-Punkt-Verriegelungssysteme, die widerstandsf\u00e4hig gegen Witterungseinfl\u00fcsse sind.<\/span><\/span><\/li>\n<\/ul>\n<p><strong><span style=\"color:#27ae60;\"><span style=\"font-size:20px;\">Erfahren Sie mehr \u00fcber <\/span><\/span><span style=\"font-size:20px;\"><a href=\"https:\/\/www.daelimtransformer.com\/de\/transformers-solutions-for-energy-storage.html\" target=\"_blank\"><span style=\"color:#c0392b;\">Transformatorl\u00f6sungen f\u00fcr Energy Story<\/span><\/a><\/span><\/strong><\/p>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"row\">\n<div class=\"signleContent col-lg-6 mb-3\">\n<p>                                                <img decoding=\"async\" class=\"img-fluid\" src=\"\/media\/115\/4-mva-pad-mounted-transformer-Compartment-Details.webp\" alt=\"Details zum Fach\"><\/p><\/div>\n<div class=\"signleContent col-lg-6 mb-3\">\n<div class=\"line-height-22 mt-3 fs-16 text-dark\">\n<h3 style=\"text-align: justify;\"><span class=\"ez-toc-section\" id=\"Compartment_Details\"><\/span><strong><span style=\"font-size:18px;\">Details zum Fach<\/span><\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p><span style=\"font-size:16px;\"><strong>12,47 kV Fachbereich<\/strong><\/span><\/p>\n<ul>\n<li><span style=\"font-size:16px;\">Loop-F\u00fctterungsdurchf\u00fchrungen f\u00fcr die Beendigung mit 600 Ampere Totenbruchschenkel, die den ANSI C57.12.26 Standards entsprechen. <\/span><\/li>\n<li><span style=\"font-size:16px;\">Tote Frontkonstruktion, Aussto\u00dfsicherungen und NEMA 2-Loch-Tankerdung. Um das Problem \u00fcberm\u00e4\u00dfigen Stroms zu beheben, entschieden sich die Ingenieure f\u00fcr den Schutz durch den Einsatz von sechs Bay-O-Net-Sicherungen.<\/span><\/li>\n<\/ul>\n<p><strong><span style=\"font-size:16px;\">34,5 kV Fachbereich<\/span><\/strong><\/p>\n<ul>\n<li><span style=\"font-size:16px;\">\u00c4hnliche Spezifikationen wie der 12,47 kV Fachbereich, die den ANSI C57.12.26 Standards entsprechen.<\/span><\/li>\n<\/ul>\n<p><strong><span style=\"font-size: 16px;\">Fachstandort<\/span><\/strong><\/p>\n<ul>\n<li><span style=\"font-size:16px;\">Hoch- und Niederspannungsf\u00e4cher befinden sich an einer Seite des Transformatorbeh\u00e4lters, getrennt durch eine vertikale Stahlbarriere.<\/span><\/li>\n<\/ul>\n<p>                                                    <a class=\"btn btn-primary mt-1 font-weight-bold fs-16 pageBtn quoteModal\" href=\"javascript:0;\">Jetzt Anfrage senden<\/a><\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>\n<div class=\"row\">\n<div class=\"col-lg-12 article-content\">\n<p style=\"text-align: justify;\"><span style=\"color:#27ae60;\"><span style=\"font-size:20px;\"><strong>Mehr Lesen \u00dcber <\/strong><\/span><\/span><span style=\"font-size:20px;\"><strong><a href=\"https:\/\/www.daelimtransformer.com\/de\/4-mva-pad-mounted-transformer.html\" target=\"_blank\"><span style=\"color:#c0392b;\">4 MVA Pad-Mounted Transformator<\/span><\/a><\/strong><\/span><\/p>\n<h3 style=\"text-align: justify;\"><span class=\"ez-toc-section\" id=\"Finish_and_Coating\"><\/span><strong><span style=\"font-size:16px;\"><span style=\"color:#000000;\">Oberfl\u00e4che und Beschichtung<\/span><\/span><\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n<ul>\n<li><span style=\"font-size:16px;\"><span style=\"color:#000000;\">ANSI 61 hellgraue Schutzbeschichtung, widerstandsf\u00e4hig gegen Korrosion. Ausbesserungsfarbe bereitgestellt.<\/span><\/span><\/li>\n<\/ul>\n<h3><span class=\"ez-toc-section\" id=\"Sectionalizing_Oil_Immersed_Load_Break_Primary_Switches\"><\/span><strong><span style=\"font-size:16px;\"><span style=\"color:#000000;\">Sektionierende, \u00f6lgetauchte Lasttrennschalter<\/span><\/span><\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n<ul>\n<li><span style=\"font-size:16px;\"><span style=\"color:#000000;\">Bewertungen: 38 kV und 300 Amperes<\/span><\/span><\/li>\n<li><span style=\"font-size:16px;\"><span style=\"color:#000000;\">Design: Zwei-Positionen, gruppengesteuert, drehbar, dauerhaft befestigt und mit einem Haken stock auf beiden ankommenden und ausgehenden Seiten bedienbar.<\/span><\/span><\/li>\n<\/ul>\n<h3><span class=\"ez-toc-section\" id=\"Factory_Tests\"><\/span><strong><span style=\"color: rgb(0, 0, 0); font-size: 16px;\">Werkspr\u00fcfungen<\/span><\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n<ul>\n<li><span style=\"font-size:16px;\"><span style=\"color:#000000;\">Daelim Transformer verpflichtet sich, umfassende Werkspr\u00fcfungen nach den ANSI\/IEEE C57.12.90 Standards durchzuf\u00fchren. Dazu geh\u00f6ren Widerstandsmessungen, Polarit\u00e4ts- und Phasenverh\u00e4ltnisse, Verh\u00e4ltnis, Leerlauf- und Lastverluste, Impulspr\u00fcfungen, Analyse von gel\u00f6stem Gas im \u00d6l, Isolationsleistungsfaktorpr\u00fcfung und \u00d6ltest.<\/span><\/span><\/li>\n<\/ul>\n<p><span style=\"color:#27ae60;\"><span style=\"font-size:20px;\"><strong>Sie k\u00f6nnten genie\u00dfen:&nbsp;<\/strong><\/span><\/span><span style=\"font-size:20px;\"><strong><a href=\"https:\/\/www.daelimtransformer.com\/de\/a-transformer-test.html\" target=\"_blank\"><span style=\"color:#c0392b;\">Wissen Sie, wie man einen Transformatorentest durchf\u00fchrt?<\/span><\/a><\/strong><\/span><\/p>\n<h3><span class=\"ez-toc-section\" id=\"Delivery_Commitments\"><\/span><strong><span style=\"color: rgb(0, 0, 0); font-size: 16px;\">Lieferverpflichtungen<\/span><\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n<ul>\n<li><span style=\"font-size:16px;\"><span style=\"color:#000000;\">Nach dem fabrikseitigen Abnahmetest (FAT) verpflichtet sich Daelim Transformer, elektronische Pr\u00fcfberichte innerhalb von drei Tagen vorzulegen. Innerhalb von zwei Monaten nach Auftragserteilung wird das Unternehmen dem Kunden alle relevanten Dokumente zur Verf\u00fcgung stellen, einschlie\u00dflich Umrisszeichnungen, Typenschildzeichnung, Schalt- und Verdrahtungsdiagramme sowie Produktdatenbl\u00e4tter.<\/span><\/span><\/li>\n<\/ul>\n<h2><span class=\"ez-toc-section\" id=\"Daelim_Transformer_%E2%80%93_Elevating_BESS_Solutions\"><\/span><span style=\"font-size:20px;\"><strong><span style=\"color:#000000;\">Daelim Transformator \u2013 Verbesserung von BESS-L\u00f6sungen<\/span><\/strong><\/span><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><iframe allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" allowfullscreen=\"\" frameborder=\"0\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/48PRtARm8ek?si=RrJQBIzC5rOfAFN8\" title=\"YouTube Video-Player\" width=\"100%\"><\/iframe><span style=\"font-size:16px;\"><span style=\"color:#000000;\">W\u00e4hlen Sie Daelim Transformer f\u00fcr Ihre Energiespeicherprojekte. Es gibt ein professionelles und erfahrenes Ingenieurteam, das Ihnen die besten Transformatorl\u00f6sungen und -optionen bietet. Daelim Transformer hat mehr als 100 BESS-Projekte und \u00fcber 500 MW erfolgreich betreut. <\/span><\/span><span style=\"font-size:18px;\"><strong><a href=\"https:\/\/www.daelimtransformer.com\/de\/certificate.html\" target=\"_blank\"><span style=\"color:#990033;\">UL gelisteter<\/span><\/a><\/strong><\/span><span style=\"font-size:16px;\"><span style=\"color:#000000;\"> Transformator mit einer Lieferzeit von unter 30 Wochen f\u00fcr die meisten Projekte. <\/span><\/span><\/p>\n<p><span style=\"color:#27ae60;\"><span style=\"font-size:20px;\"><strong>Hier klicken, um mehr zu \u00fcberpr\u00fcfen.<\/strong><\/span><\/span><span style=\"font-size:20px;\"><strong><a href=\"https:\/\/www.daelimtransformer.com\/de\/transformer-project.html\" target=\"_blank\"><span style=\"color:#c0392b;\"> Projekte von Daelim Transformer<\/span><\/a><\/strong><\/span><\/p>\n<\/p><\/div>\n<\/p><\/div>\n<\/p><\/div>","protected":false},"excerpt":{"rendered":"<p>Today, Daelim Transformer is proud to introduce a pad-mounted transformer for a 4.0 MVA Battery Energy Storage System (BESS) project located in Riverside County, California. This pad-mounted transformer is specifically designed for deployment at a Battery Energy Storage power generation facility. Its robust design is engineered to withstand harmonic voltages and currents emanating from inverters, [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":8210,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[278,284],"tags":[],"class_list":["post-8209","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-daelims-project","category-north-america"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/posts\/8209","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/comments?post=8209"}],"version-history":[{"count":0,"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/posts\/8209\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/media\/8210"}],"wp:attachment":[{"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/media?parent=8209"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/categories?post=8209"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.daelimtransformer.com\/de\/wp-json\/wp\/v2\/tags?post=8209"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}