{"id":7014,"date":"2026-01-05T03:49:09","date_gmt":"2026-01-05T03:49:09","guid":{"rendered":"https:\/\/daelimtransformer.com\/?p=7014"},"modified":"2026-03-08T08:22:27","modified_gmt":"2026-03-08T08:22:27","slug":"what-is-a-substation-transformer","status":"publish","type":"post","link":"https:\/\/www.daelimtransformer.com\/pl\/a-substation-transformer.html","title":{"rendered":"Czym jest transformator stacji transformacyjnej?"},"content":{"rendered":"<div id=\"contentMain\" class=\"article-content\">\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><img decoding=\"async\" src=\"\/media\/115\/2000kva%2033kv%20substation%20transformer.jpg\" \/><\/p>\n<h2><span class=\"ez-toc-section\" id=\"1What_is_substation_transformer\"><\/span>1. Czym jest transformator stacji rozdzielczej?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><a href=\"https:\/\/www.daelimtransformer.com\/pl\/1500-kva-substation-transformer.html\"><img decoding=\"async\" style=\"float: right; width: 340px; height: 340px;\" src=\"\/media\/115\/1500-kva-substation-transformer.webp\" \/><\/a><a href=\"https:\/\/www.daelimtransformer.com\/pl\/substation-transformer.html\">Transformatory stacyjne<\/a> s\u0105 zaprojektowane do instalacji w du\u017cych lub ma\u0142ych tr\u00f3jfazowych systemach przesy\u0142owych i dystrybucyjnych. Miejsce instalacji jest powszechne i musi znajdowa\u0107 si\u0119 na betonowej podstawie wewn\u0119trznej lub zewn\u0119trznej, kt\u00f3ra musi by\u0107 zaprojektowana przez in\u017cyniera energetycznego we wczesnym etapie planowania projektu.<\/p>\n<p>Jednocze\u015bnie kable po stronie wysokiego napi\u0119cia lub niskiego napi\u0119cia transformatora stacji rozdzielczej b\u0119d\u0105 pod\u0142\u0105czane przez tulej\u0119 na ko\u0144cu w kszta\u0142cie gard\u0142a lub tulej\u0119 na g\u00f3rze, aby bezpo\u015brednio wprowadzi\u0107 pr\u0105d do pomieszczenia operacyjnego innego sprz\u0119tu stacji rozdzielczej, takiego jak szafa sterownicza i inny sprz\u0119t.<\/p>\n<p>Ponadto, transformatory stacji transformacyjnych s\u0105 zazwyczaj zanurzone w oleju. Olej mineralny, olej ro\u015blinny lub olej krzemionkowy dla transformator\u00f3w. Szeroko stosowane w r\u00f3\u017cnych zastosowaniach u\u017cyteczno\u015bci publicznej lub ma\u0142ego przemys\u0142u. Standardy budowlane oparte s\u0105 zazwyczaj na standardach IEC, IEEE lub innych standardach mi\u0119dzynarodowych. Porozmawiajmy o klasie napi\u0119cia transformator\u00f3w w stacjach transformacyjnych. Napi\u0119cie pierwotne transformator\u00f3w w stacjach transformacyjnych wynosi zazwyczaj minimum 2,4 kV i maksimum 69 kV, co oparte jest na standardzie IEEE. Minimalna moc to 150 kVA do maksimum. <a href=\"https:\/\/www.daelimtransformer.com\/pl\/20-mva-substation-transformer.html\">20MVA<\/a>, a napi\u0119cie wt\u00f3rne mo\u017ce by\u0107 r\u00f3wnie\u017c minimalnym napi\u0119ciem wynosz\u0105cym 0,6 kV i maksymalnie 35 kV.<\/p>\n<p>Jednocze\u015bnie transformatory stacji rozdzielczej mo\u017cna podzieli\u0107 na publiczne transformatory stacji rozdzielczej i osobiste przemys\u0142owe transformatory stacji rozdzielczej pod wzgl\u0119dem scenariuszy u\u017cytkowania:<\/p>\n<h3><span class=\"ez-toc-section\" id=\"_Utility_substation_transformers\"><\/span>* Transformatory stacji rozdzielczej u\u017cyteczno\u015bci:<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 10.5pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 10.5000pt;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"font-family: Calibri;\">W tym przypadku s\u0105 one u\u017cywane przez przemys\u0142owe firmy dystrybucji energii, a nast\u0119pnie napi\u0119cie wyj\u015bciowe jest w ko\u0144cu u\u017cywane przez prywatnych konsument\u00f3w indywidualnych. Wyj\u015bcie zar\u00f3wno pr\u0105du jednofazowego, jak i tr\u00f3jfazowego. Niekt\u00f3re powszechnie u\u017cywane to 120V, 240V, 400V itd. U\u017cywane w miejskim lub wiejskim sprz\u0119cie dystrybucji energii. Nast\u0119pnie zasilane do wielu lub pojedynczych transformator\u00f3w niskonapi\u0119ciowych o ma\u0142ej mocy. Transformatory miejskich stacji rozdzielczych s\u0105 zazwyczaj budowane z ceg\u0142y do stworzenia \u015bciany ochronnej, a transformatory wiejskich stacji rozdzielczych og\u00f3lnie wyst\u0119puj\u0105 na zewn\u0119trznych s\u0142upach i wie\u017cach.<\/span><\/span><\/span><\/span><\/span><\/p>\n<p><strong>Mo\u017cesz by\u0107 zainteresowany:\u00a0<a href=\"https:\/\/www.daelimtransformer.com\/pl\/utility-transformer.html\">Ostateczny przewodnik po transformatorach u\u017cyteczno\u015bci publicznej<\/a><\/strong><\/p>\n<h3><span class=\"ez-toc-section\" id=\"Personal_substation_transformers\"><\/span>* Osobiste transformatory stacji rozdzielczej<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Rozumiemy, \u017ce transformator stacji transformacyjnej u\u017cywany przez ostatecznego u\u017cytkownika jest przeznaczony do osobistego u\u017cytku ko\u0144cowego. Zazwyczaj jest zasilany przez sieci o \u015brednich i niskich poziomach napi\u0119cia i jest u\u017cywany w szko\u0142ach, szpitalach, restauracjach itp.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Underground_substation_transformer\"><\/span>* Podziemny transformator stacji rozdzielczej<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Czasami z powodu ogranicze\u0144 przestrzennych, specjalnie zaprojektowany transformator stacji rozdzielczej mo\u017ce by\u0107 u\u017cywany w celu spe\u0142nienia wymaga\u0144 ekologicznych. Nale\u017cy zwr\u00f3ci\u0107 uwag\u0119 tylko na specjalne wymagania dotycz\u0105ce podziemia:<\/p>\n<p>W przypadku instalacji o ograniczonej przestrzeni, w kwestii bezpiecze\u0144stwa nale\u017cy wzi\u0105\u0107 pod uwag\u0119 specjalne media i specjalne oleje, a w kwestii jako\u015bci nale\u017cy bra\u0107 pod uwag\u0119 najwy\u017csz\u0105 jako\u015b\u0107, aby zminimalizowa\u0107 ryzyko operacyjne i korzy\u015bci ekonomiczne z dzia\u0142ania maszyny.<\/p>\n<p><strong>Mo\u017cesz by\u0107 zainteresowany:\u00a0<a href=\"https:\/\/www.daelimtransformer.com\/pl\/pad-mounted-transformer.html\">Transformator montowany na pod\u0142o\u017cu<\/a><\/strong><\/p>\n<h2><span class=\"ez-toc-section\" id=\"2How_does_a_substation_transformer_work\"><\/span>2. Jak dzia\u0142a transformator stacji rozdzielczej?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 10.5pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 10.5000pt;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"font-family: Calibri;\">G\u0142\u00f3wne \u017ar\u00f3d\u0142o zasilania transformatora w stacji rozdzielczej polega na wprowadzeniu pr\u0105du zmiennego do sieci dystrybucyjnej w celu pracy. Proste zrozumienie zasady polega na tym, \u017ce olej transformatorowy w stacji rozdzielczej sk\u0142ada si\u0119 z dw\u00f3ch s\u0105siaduj\u0105cych ze sob\u0105 cewkowych zwoj\u00f3w. Pole magnetyczne wyst\u0119puje, gdy napi\u0119cie przep\u0142ywa przez jedn\u0105 z cewek zwoj\u00f3w. Pole magnetyczne, kt\u00f3re tutaj wyst\u0119puje, sprz\u0119ga si\u0119 z bezpo\u015brednio s\u0105siedni\u0105 cewk\u0105 zwoj\u00f3w, odbiera napi\u0119cie i reaguje na nie. <\/span><\/span><\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 10.5pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 10.5000pt;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"font-family: Calibri;\">Stosunek indukowanego napi\u0119cia transformatora stacji transformacyjnej do p\u0119tli cewki uzwojenia staje si\u0119 kryterium proporcjonalno\u015bci. Na przyk\u0142ad, gdy przesy\u0142ane jest 10 000 p\u0119tli, w te\u015bcie dystrybucji generowane b\u0119dzie 1 000 p\u0119tli, a napi\u0119cie generowane w te\u015bcie dystrybucji zostanie zmniejszone 10-krotnie. Ta zasada jest dobrze zrozumiana, dlatego mo\u017cemy zwi\u0119ksza\u0107 lub zmniejsza\u0107 ci\u015bnienie zgodnie z potrzebami korzystania z energii elektrycznej, aby dobrze spe\u0142ni\u0107 wymagania dotycz\u0105ce r\u00f3wnowagi ka\u017cdego elementu sieci elektroenergetycznej, zapewniaj\u0105c bezpiecze\u0144stwo i op\u0142acalno\u015b\u0107 ka\u017cdego obwodu.<\/span><\/span><\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><img decoding=\"async\" src=\"\/media\/115\/Oil%20immersed%20distribution%20transformer.jpg\" \/><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 10.5pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 10.5000pt;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"font-family: Calibri;\">Jednocze\u015bnie transformatory stacji transformacyjnych obejmuj\u0105 r\u00f3wnie\u017c urz\u0105dzenia, kt\u00f3re kontroluj\u0105 ca\u0142\u0105 sie\u0107 przesy\u0142ow\u0105 i dystrybucyjn\u0105. Na przyk\u0142ad, transformator wy\u0142\u0105cznika to ma\u0142y transformator, kt\u00f3ry g\u0142\u00f3wnie s\u0142u\u017cy do monitorowania wydajno\u015bci bezpiecze\u0144stwa oraz wykrywania pr\u0105du i mocy. W ten spos\u00f3b mo\u017cna osi\u0105gn\u0105\u0107 bezpieczn\u0105 prac\u0119 ca\u0142ego sprz\u0119tu stacji transformacyjnej, uzupe\u0142niaj\u0105c transformatory stacji transformacyjnych. W zale\u017cno\u015bci od strat podczas przesy\u0142ania i dystrybucji, napi\u0119cie w sieci mo\u017ce waha\u0107 si\u0119 poza dopuszczalnym zakresem.<\/span><\/span><\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 10.5pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 10.5000pt;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"font-family: Calibri;\">W rzeczywisto\u015bci, w wielu perspektywach i aspektach, system elektroenergetyczny, a nawet transformator stacji transformacyjnej jest ogromnym systemem sprz\u0119towym, kt\u00f3ry mo\u017ce by\u0107 powi\u0105zany z \u017cyciem ka\u017cdego z nas. Niezale\u017cnie od tego, czy jest to podstawowy sprz\u0119t, czy codzienne zu\u017cycie energii elektrycznej przez wszystkich, energia elektryczna b\u0119dzie u\u017cywana, szczeg\u00f3lnie niezawodna i bezpieczna energia elektryczna. Chocia\u017c rozmiar miejsca u\u017cycia i poziom napi\u0119cia u\u017cywanej energii s\u0105 r\u00f3\u017cne.<\/span><\/span><\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 10.5pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 10.5000pt;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"font-family: Calibri;\">Ka\u017cdy transformator stacji transformacyjnej jest unikalny i dostosowany do potrzeb. Wraz z inteligentnym rozwojem urz\u0105dze\u0144 elektroenergetycznych oraz szybkim rozwojem r\u00f3\u017cnych zr\u00f3wnowa\u017conych i przyjaznych dla \u015brodowiska \u017ar\u00f3de\u0142 energii, uwa\u017ca si\u0119, \u017ce transformatory stacji transformacyjnych przynios\u0105 wi\u0119cej wyzwa\u0144 w naszym przysz\u0142ym \u017cyciu. A tak\u017ce mo\u017cliwo\u015b\u0107 opracowania wi\u0119kszego bezpiecze\u0144stwa i niezawodno\u015bci.<\/span><\/span><\/span><\/span><\/span><\/p>\n<h2><span class=\"ez-toc-section\" id=\"3What_types_of_substation_transformer_are_there\"><\/span>3. Jakie rodzaje transformator\u00f3w stacji rozdzielczej istniej\u0105?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<\/div>\n<div><a href=\"https:\/\/www.daelimtransformer.com\/pl\/69kv-transformer.html\"><img decoding=\"async\" class=\"alignright\" style=\"width: 264px; height: 279px; float: right;\" src=\"\/media\/115\/canada-69-kv-transformer.webp\" \/><\/a><\/div>\n<div class=\"article-content\">\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 10.5pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 10.5000pt;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"font-weight: normal;\"><span style=\"font-family: Calibri;\">Mo\u017cemy podzieli\u0107 to na wiele poziom\u00f3w, aby zrozumie\u0107 r\u00f3\u017cne typy transformator\u00f3w stacji transformacyjnych:<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 10.5pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 10.5000pt;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"font-weight: normal;\"><span style=\"font-family: Calibri;\">*Aby odr\u00f3\u017cni\u0107 wed\u0142ug poziomu napi\u0119cia:<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 10.5pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 10.5000pt;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"font-weight: normal;\"><span style=\"font-family: Calibri;\">Transformator stacji transformacyjnej wysokiego napi\u0119cia<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 10.5pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 10.5000pt;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"font-weight: normal;\"><span style=\"font-family: Calibri;\">Zakres napi\u0119cia wynosi minimum <a href=\"https:\/\/www.daelimtransformer.com\/pl\/69kv-power-transformer.html\" target=\"_blank\" rel=\"noopener\">11 kV do maksimum 69 kV.<\/a><\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 10.5pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 10.5000pt;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"font-weight: normal;\"><span style=\"font-family: Calibri;\">Transformator EHV<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 10.5pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 10.5000pt;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"font-weight: normal;\"><span style=\"font-family: Calibri;\">Zakres napi\u0119cia od minimum <a href=\"https:\/\/www.daelimtransformer.com\/pl\/138kv-power-transformer.html\" target=\"_blank\" rel=\"noopener\">132 kV do maksimum 440 kV.<\/a><\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 10.5pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 10.5000pt;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"font-weight: normal;\"><span style=\"font-family: Calibri;\">Jest podwy\u017cszenie z niskiego napi\u0119cia do wysokiego napi\u0119cia oraz transformator stacji transformacyjnej obni\u017caj\u0105cej napi\u0119cie z wysokiego napi\u0119cia do niskiego napi\u0119cia.<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 10.5pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 10.5000pt;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"font-weight: normal;\"><span style=\"font-family: Calibri;\">* Jednocze\u015bnie istnieje transformator stacji transformacyjnej, kt\u00f3ry nie zmienia napi\u0119cia, odnosz\u0105cy si\u0119 do transformatora stacji transformacyjnej, kt\u00f3ry izoluje moc w kr\u00f3tkim okresie czasu i odgrywa rol\u0119 w izolacji i bezpiecze\u0144stwie w przypadku awarii zasilania.<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 10.5pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 10.5000pt;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"font-weight: normal;\"><span style=\"font-family: Calibri;\">*Istnieje r\u00f3wnie\u017c transformator stacji transformacyjnej, kt\u00f3ry zmienia cz\u0119stotliwo\u015b\u0107<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 10.5pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 10.5000pt;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"font-weight: normal;\"><span style=\"font-family: Calibri;\">Poniewa\u017c zmienia cz\u0119stotliwo\u015b\u0107, nazywa si\u0119 go zmienno-frequencyjnym transformatorem stacji transformacyjnej, kt\u00f3ry rzadziej stosowany jest przez indywidualnych mieszka\u0144c\u00f3w, a g\u0142\u00f3wnie w stacjach transformacyjnych przemys\u0142owych.<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 10.5pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 10.5000pt;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"font-weight: normal;\"><span style=\"font-family: Calibri;\">Bardziej bezpo\u015brednio, istnieje transformator stacji transformacyjnej, kt\u00f3ry zmienia <a href=\"https:\/\/en.wikipedia.org\/wiki\/Power_supply\" target=\"_blank\" rel=\"noopener\">zasilanie AC\/DC.<\/a>. G\u0142\u00f3wnie wykorzystywane w trakcji galwanoplastycznej.<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 10.5pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 10.5000pt;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"font-weight: normal;\"><span style=\"font-family: Calibri;\">*Istnieje r\u00f3wnie\u017c r\u00f3\u017cnica oparta na lokalizacji dystrybucji sieci energetycznej: istniej\u0105 dwa g\u0142\u00f3wne typy<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 10.5pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 10.5000pt;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"font-weight: normal;\"><span style=\"font-family: Calibri;\">Stacje transformatorowe typu sieciowego, kt\u00f3re s\u0105 g\u0142\u00f3wnie u\u017cywane do przesy\u0142ania du\u017cych ilo\u015bci energii elektrycznej o wysokim napi\u0119ciu, mog\u0105 by\u0107 u\u017cywane tylko w budynkach na zewn\u0105trz.<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 10.5pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 10.5000pt;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"font-weight: normal;\"><span style=\"font-family: Calibri;\">Drugim rodzajem s\u0105 bardziej powszechne w naszym otoczeniu, czyli transformatory stacji transformacyjnych w miastach i na wsiach. G\u0142\u00f3wne zastosowanie to praca przy niskich i \u015brednich napi\u0119ciach od 10KV do 33KV.<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 10.5pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 10.5000pt;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"font-weight: normal;\"><span style=\"font-family: Calibri;\">Powy\u017cej przedstawiono, jak rozr\u00f3\u017cnia\u0107 r\u00f3\u017cne transformatory stacji transformacyjnych. Mo\u017cemy to zrozumie\u0107 z r\u00f3\u017cnych perspektyw i kontekst\u00f3w.<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<h2><span class=\"ez-toc-section\" id=\"4How_much_does_a_substation_transformer_weight\"><\/span>4. Ile wa\u017cy transformator stacji rozdzielczej?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<table align=\"center\">\n<tbody>\n<tr>\n<td rowspan=\"2\" valign=\"center\" width=\"7.0000%\">\n<p align=\"center\">(KVA)<\/p>\n<p align=\"center\">Nominalne<\/p>\n<p align=\"center\">Moc<\/p>\n<\/td>\n<td rowspan=\"2\" valign=\"center\" width=\"8.0600%\">\n<p align=\"center\">(KV)<\/p>\n<p align=\"center\">Wysoki<\/p>\n<p align=\"center\">Napi\u0119cie<\/p>\n<\/td>\n<td rowspan=\"2\" valign=\"center\" width=\"8.2800%\">\n<p align=\"center\">(V)<\/p>\n<p align=\"center\">Niski<\/p>\n<p align=\"center\">Napi\u0119cie<\/p>\n<\/td>\n<td rowspan=\"2\" valign=\"center\" width=\"12.2200%\">\n<p align=\"center\">Typ po\u0142\u0105czenia<\/p>\n<p align=\"center\">Symbol<\/p>\n<\/td>\n<td rowspan=\"2\" valign=\"center\" width=\"13.0400%\">\n<p align=\"center\">(%)<\/p>\n<p align=\"center\">Kr\u00f3tki<\/p>\n<p align=\"center\">Obw\u00f3d<\/p>\n<p align=\"center\">Impedancja<\/p>\n<\/td>\n<td colspan=\"2\" valign=\"center\" width=\"17.3800%\">\n<p align=\"center\">(W)<\/p>\n<p align=\"center\">Strata<\/p>\n<\/td>\n<td rowspan=\"2\" valign=\"center\" width=\"17.5400%\">\n<p align=\"center\">Odniesienie<\/p>\n<p align=\"center\">Wymiary<\/p>\n<p align=\"center\">(W*H*D)<\/p>\n<p align=\"center\">mm<\/p>\n<\/td>\n<td rowspan=\"2\" valign=\"center\" width=\"16.4000%\">\n<p align=\"center\">Referencja<\/p>\n<p align=\"center\">Waga<\/p>\n<p align=\"center\">kg<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"8.5400%\">\n<p align=\"center\">(W)<\/p>\n<p align=\"center\">Strata na ja\u0142owym<\/p>\n<\/td>\n<td valign=\"center\" width=\"8.8200%\">\n<p align=\"center\">\u00a0(W)<\/p>\n<p align=\"center\">Strata pod obci\u0105\u017ceniem<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"7.0000%\">\n<p align=\"center\">800<\/p>\n<\/td>\n<td rowspan=\"10\" valign=\"center\" width=\"8.0600%\">\n<p align=\"center\">4.16<\/p>\n<p align=\"center\">12.00<\/p>\n<p align=\"center\">12.47<\/p>\n<p align=\"center\">13.2<\/p>\n<p align=\"center\">13.8<\/p>\n<p align=\"center\">14.4<\/p>\n<p align=\"center\">23.0<\/p>\n<p align=\"center\">24.94<\/p>\n<p align=\"center\">34.5<\/p>\n<p align=\"center\">34.8                   44                        lub inne<\/p>\n<\/td>\n<td rowspan=\"10\" valign=\"center\" width=\"8.2800%\">\n<p align=\"justify\">208\/120<\/p>\n<p align=\"center\">415\/240<\/p>\n<p align=\"center\">480\/277<\/p>\n<p align=\"center\">400<\/p>\n<p align=\"center\">600<\/p>\n<p align=\"center\">12000<\/p>\n<p align=\"center\">12470<\/p>\n<p align=\"center\">13200<\/p>\n<p align=\"center\">13800<\/p>\n<p align=\"center\">lub inne<\/p>\n<\/td>\n<td rowspan=\"10\" valign=\"center\" width=\"12.2200%\">\n<p align=\"center\">Dyn1<\/p>\n<p align=\"center\">Ynyn0<\/p>\n<p align=\"center\">Dyn11<\/p>\n<p align=\"center\">Dd0<\/p>\n<p align=\"center\">Ynd11<\/p>\n<p align=\"center\">czy<\/p>\n<p align=\"center\">inne<\/p>\n<\/td>\n<td rowspan=\"10\" valign=\"center\" width=\"13.0400%\">\n<p align=\"center\">2.7<\/p>\n<p align=\"center\">3.1<\/p>\n<p align=\"center\">4.35<\/p>\n<p align=\"center\">5.75<\/p>\n<p align=\"center\">6.0<\/p>\n<\/td>\n<td valign=\"center\" width=\"8.5400%\">\n<p align=\"center\">980<\/p>\n<\/td>\n<td valign=\"center\" width=\"8.8200%\">\n<p align=\"center\">9350<\/p>\n<\/td>\n<td valign=\"center\" width=\"17.5400%\">\n<p align=\"center\">1060*1500*1780<\/p>\n<\/td>\n<td valign=\"center\" width=\"16.4000%\">\n<p align=\"center\">2050<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"7.0000%\">\n<p align=\"center\">1000<\/p>\n<\/td>\n<td valign=\"center\" width=\"8.5400%\">\n<p align=\"center\">1160<\/p>\n<\/td>\n<td valign=\"center\" width=\"8.8200%\">\n<p align=\"center\">11500<\/p>\n<\/td>\n<td valign=\"center\" width=\"17.5400%\">\n<p align=\"center\">1085*1570*1800<\/p>\n<\/td>\n<td valign=\"center\" width=\"16.4000%\">\n<p align=\"center\">2450<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"7.0000%\">\n<p align=\"center\">1250<\/p>\n<\/td>\n<td valign=\"center\" width=\"8.5400%\">\n<p align=\"center\">1380<\/p>\n<\/td>\n<td valign=\"center\" width=\"8.8200%\">\n<p align=\"center\">13900<\/p>\n<\/td>\n<td valign=\"center\" width=\"17.5400%\">\n<p align=\"center\">1160*1610*1890<\/p>\n<\/td>\n<td valign=\"center\" width=\"16.4000%\">\n<p align=\"center\">2900<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"7.0000%\">\n<p align=\"center\">1600<\/p>\n<\/td>\n<td valign=\"center\" width=\"8.5400%\">\n<p align=\"center\">1660<\/p>\n<\/td>\n<td valign=\"center\" width=\"8.8200%\">\n<p align=\"center\">16600<\/p>\n<\/td>\n<td valign=\"center\" width=\"17.5400%\">\n<p align=\"center\">1190*1630*1950<\/p>\n<\/td>\n<td valign=\"center\" width=\"16.4000%\">\n<p align=\"center\">3400<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"7.0000%\">\n<p align=\"center\">2000<\/p>\n<\/td>\n<td valign=\"center\" width=\"8.5400%\">\n<p align=\"center\">2030<\/p>\n<\/td>\n<td valign=\"center\" width=\"8.8200%\">\n<p align=\"center\">18300<\/p>\n<\/td>\n<td valign=\"center\" width=\"17.5400%\">\n<p align=\"center\">1260*1700*2090<\/p>\n<\/td>\n<td valign=\"center\" width=\"16.4000%\">\n<p align=\"center\">4100<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"7.0000%\">\n<p align=\"center\">2500<\/p>\n<\/td>\n<td valign=\"center\" width=\"8.5400%\">\n<p align=\"center\">2450<\/p>\n<\/td>\n<td valign=\"center\" width=\"8.8200%\">\n<p align=\"center\">19600<\/p>\n<\/td>\n<td valign=\"center\" width=\"17.5400%\">\n<p align=\"center\">1150*2150*2250<\/p>\n<\/td>\n<td valign=\"center\" width=\"16.4000%\">\n<p align=\"center\">4750<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"7.0000%\">\n<p align=\"center\">3000<\/p>\n<\/td>\n<td valign=\"center\" width=\"8.5400%\">\n<p align=\"center\">3240<\/p>\n<\/td>\n<td valign=\"center\" width=\"8.8200%\">\n<p align=\"center\">26500<\/p>\n<\/td>\n<td valign=\"center\" width=\"17.5400%\">\n<p align=\"center\">1900*2600*2150<\/p>\n<\/td>\n<td valign=\"center\" width=\"16.4000%\">\n<p align=\"center\">6500<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"7.0000%\">\n<p align=\"center\">5000<\/p>\n<\/td>\n<td valign=\"center\" width=\"8.5400%\">\n<p align=\"center\">4500<\/p>\n<\/td>\n<td valign=\"center\" width=\"8.8200%\">\n<p align=\"center\">27000<\/p>\n<\/td>\n<td valign=\"center\" width=\"17.5400%\">\n<p align=\"center\">2500*2210*3180<\/p>\n<\/td>\n<td valign=\"center\" width=\"16.4000%\">\n<p align=\"center\">9500<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"7.0000%\">\n<p align=\"center\">7500<\/p>\n<\/td>\n<td valign=\"center\" width=\"8.5400%\">\n<p align=\"center\">7200<\/p>\n<\/td>\n<td valign=\"center\" width=\"8.8200%\">\n<p align=\"center\">32000<\/p>\n<\/td>\n<td valign=\"center\" width=\"17.5400%\">\n<p align=\"center\">3660*3100*5100<\/p>\n<\/td>\n<td valign=\"center\" width=\"16.4000%\">\n<p align=\"center\">13600<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"center\" width=\"7.0000%\">\n<p align=\"center\">10000<\/p>\n<\/td>\n<td valign=\"center\" width=\"8.5400%\">\n<p align=\"center\">8500<\/p>\n<\/td>\n<td valign=\"center\" width=\"8.8200%\">\n<p align=\"center\">35500<\/p>\n<\/td>\n<td valign=\"center\" width=\"17.5400%\">\n<p align=\"center\">3830*2640*2216<\/p>\n<\/td>\n<td valign=\"center\" width=\"16.4000%\">\n<p align=\"center\">15800<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>* Wymiary, waga i straty s\u0105 podane dla odniesienia. Zostan\u0105 dostosowane na podstawie rzeczywistego projektu, projektu i norm.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"5Substation_transformer_testing\"><\/span>5. Testowanie transformatora stacji rozdzielczej?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><img decoding=\"async\" class=\"alignright\" style=\"width: 339px; height: 314px; float: right;\" src=\"\/media\/115\/power-transformer-routine-tests.webp\" \/><span style=\"font-size: 10.5pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 10.5000pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-weight: normal;\">Testowanie transformator\u00f3w ewoluowa\u0142o przez d\u0142ugi czas i wci\u0105\u017c ewoluuje od momentu powstania transformatora. Od pocz\u0105tku, gdy dane testowe by\u0142y niezadowalaj\u0105ce, do danych testowych, kt\u00f3re mog\u0105 pokaza\u0107 z\u0142o\u017cone dane i struktur\u0119 transformatora od zewn\u0105trz do wewn\u0105trz, co niew\u0105tpliwie dowodzi, \u017ce transformator odegra\u0142 bezpieczn\u0105 i niezawodn\u0105 rol\u0119 profesjonaln\u0105 w ca\u0142ym rozwoju energetycznym. Mo\u017cemy teraz om\u00f3wi\u0107 te same i r\u00f3\u017cne tre\u015bci testowe wed\u0142ug najszerzej stosowanych standard\u00f3w IEC i IEEE.<\/span><\/span><\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 10.5pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 10.5000pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-weight: normal;\">\u00a0Pod norm\u0105 IEC istniej\u0105 tre\u015bci testowe:<\/span><\/span><\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 10.5pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 10.5000pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-weight: normal;\">\u2013 Test dielektryczny<\/span><\/span><\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 10.5pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 10.5000pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-weight: normal;\">\u2013 Test impulsowy<\/span><\/span><\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 10.5pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 10.5000pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-weight: normal;\">\u2013 Test impulsu piorunowego<\/span><\/span><\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 10.5pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 10.5000pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-weight: normal;\">\u2013 Test ci\u015bnienia<\/span><\/span><\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 10.5pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 10.5000pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-weight: normal;\">\u2013 Pomiar wy\u0142adowania cz\u0119\u015bciowego, test wy\u0142adowania pe\u0142nego, test wy\u0142adowania harmonicznego<\/span><\/span><\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 10.5pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 10.5000pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-weight: normal;\">\u2013 Test wymuszonego napi\u0119cia AC,<\/span><\/span><\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 10.5pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 10.5000pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-weight: normal;\">- Test strat bezobci\u0105\u017ceniowych, test strat obci\u0105\u017ceniowych<\/span><\/span><\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 10.5pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 10.5000pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-weight: normal;\">- Test wzrostu temperatury<\/span><\/span><\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 10.5pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 10.5000pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-weight: normal;\">Te testy mog\u0105 by\u0107 obowi\u0105zkowe lub nieobowi\u0105zkowe, ale mog\u0105 by\u0107 negocjowane w zale\u017cno\u015bci od rzeczywistych warunk\u00f3w eksperymentalnych producenta i potrzeb klienta.<\/span><\/span><\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"color: #27ae60;\"><strong><span style=\"font-size: 18px;\"><span style=\"font-family: Calibri;\">Czytanie wi\u0119cej o <\/span><\/span><\/strong><\/span><strong><span style=\"font-size: 18px;\"><span style=\"font-family: Calibri;\"><a href=\"https:\/\/www.daelimtransformer.com\/pl\/test-of-power-transformer.html\"><span style=\"color: #c0392b;\">Test transformatora<\/span><\/a><\/span><\/span><\/strong><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><img decoding=\"async\" src=\"\/media\/115\/furnace%20transformer%20drawings.jpg\" \/><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 10.5pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 10.5000pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-weight: normal;\">Tre\u015b\u0107 testu zgodnie z normami IEEE<\/span><\/span><\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 10.5pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 10.5000pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-weight: normal;\">Najpierw powinni\u015bmy rozwa\u017cy\u0107 test oporu, test polaryzacji, test relacji fazowej, test stosunku, test strat bezobci\u0105\u017ceniowych, test strat obci\u0105\u017ceniowych oraz odpowiedni test wzrostu temperatury, test dielektryczny. Jednocze\u015bnie, aby zapewni\u0107 bezpiecze\u0144stwo testu i minimalizowa\u0107 uszkodzenia transformatora, cz\u0119\u015b\u0107 napi\u0119ciowa zwi\u0105zana z pr\u0105dem powinna by\u0107 testowana jako pierwsza.<\/span><\/span><\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 10.5pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 10.5000pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-weight: normal;\">Ponadto test piorunowy nie jest testem obowi\u0105zkowym, szczeg\u00f3lnie w warunkach ma\u0142ej pojemno\u015bci i napi\u0119cia, test piorunowy mo\u017ce spowodowa\u0107 katastrofalne straty dla transformatora, mo\u017cemy rozwa\u017cy\u0107 test pr\u00f3bny w tych warunkach.<\/span><\/span><\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 10.5pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 10.5000pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-weight: normal;\">Jednocze\u015bnie istniej\u0105 testy niskocz\u0119stotliwo\u015bciowe, testy napi\u0119cia indukowanego itp.<\/span><\/span><\/span><\/span><\/span><\/p>\n<h2><span class=\"ez-toc-section\" id=\"Substation_Transformer_Manufacturer\"><\/span>Producent transformator\u00f3w stacji rozdzielczej<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><a href=\"https:\/\/www.daelimtransformer.com\/pl\/substation-transformer.html\"><img decoding=\"async\" src=\"\/media\/115\/daelim-substation-transformer-skid-mounted-transformer.webp\" \/><\/a><\/p>\n<p><span style=\"font-size: 10.5pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 10.5000pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-weight: normal;\">Daelim Transformer jest Twoim pierwszym wyborem na wysokiej jako\u015bci transformatory stacji transformatorowych. Jako wiod\u0105cy producent i dostawca, oferujemy transformatory, kt\u00f3re spe\u0142niaj\u0105 najnowsze mi\u0119dzynarodowe standardy, w tym IEEE, ANSI, CSA, IEC oraz AS. Nasze produkty s\u0105 certyfikowane przez <span style=\"font-size: 16px;\"><strong><a href=\"https:\/\/www.daelimtransformer.com\/pl\/certificate.html\"><span style=\"color: #c0392b;\">UL, cUL, CSA, CE<\/span><\/a><\/strong><\/span>, oraz FM, zapewniaj\u0105c niezr\u00f3wnan\u0105 niezawodno\u015b\u0107 i wydajno\u015b\u0107.<\/span><\/span><\/span><\/span><\/span><\/p>\n<p><span style=\"font-size: 10.5pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 10.5000pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-weight: normal;\">Daelim Transformer mo\u017ce poszczyci\u0107 si\u0119 du\u017cym do\u015bwiadczeniem w projektach transformator\u00f3w stacji transformatorowych w Ameryce P\u00f3\u0142nocnej, Ameryce \u0141aci\u0144skiej i Australii. Oferujemy spersonalizowane rozwi\u0105zania dostosowane do Twoich specyficznych potrzeb technicznych. Nasza wiedza wykracza poza produkcj\u0119 i obejmuje kompleksowy zakres us\u0142ug, takich jak profesjonalna instalacja, sta\u0142a konserwacja oraz szybka pomoc w terenie, wszystko zaprojektowane, aby zapewni\u0107 p\u0142ynno\u015b\u0107 dzia\u0142alno\u015bci.<\/span><\/span><\/span><\/span><\/span><\/p>\n<p><span style=\"font-size: 10.5pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 10.5000pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-weight: normal;\">Z stacjami serwisowymi w Stanach Zjednoczonych, Kanadzie, Hiszpanii i innych krajach, Daelim Transformer zobowi\u0105zuje si\u0119 do dostarczania najlepszych rozwi\u0105za\u0144 transformatorowych na ca\u0142ym \u015bwiecie. Wybierz Daelim Transformer do swojego nast\u0119pnego projektu i do\u015bwiadcz r\u00f3\u017cnicy, jak\u0105 mog\u0105 przynie\u015b\u0107 wydajno\u015b\u0107 i ekspertyza.<\/span><\/span><\/span><\/span><\/span><\/p>\n<p style=\"margin: 0pt 0pt 0.0001pt; text-align: justify;\"><a href=\"https:\/\/www.daelimtransformer.com\/pl\/contact.html\" target=\"_blank\" rel=\"noopener\"><u><em><strong><span style=\"font-size: 10.5pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 10.5000pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-weight: normal;\">Serdecznie zapraszamy do sk\u0142adania zapyta\u0144 i kliknij tutaj, aby dowiedzie\u0107 si\u0119 wi\u0119cej!<\/span><\/span><\/span><\/span><\/span><\/strong><\/em><\/u><\/a><\/p>\n<p><!-- \u5de6\u53f3\u56fe\u6587--><\/p>\n<p><!-- \u8c46\u8150\u5757\u56fe\u6587\u4e0a\u4e0b--><\/p>\n<p><!--\u6587\u5b57\u6a21\u5757--><\/p>\n<p><!-- \u5de6\u53f3\u56fe\u6587--><\/p>\n<p><!--\u6587\u5b57\u6a21\u5757--><\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>1.What is substation transformer? Substation transformers are designed for installation in large or small three-phase transmission and distribution power systems. The installation location is common and must be on the indoor or outdoor concrete base, which needs to be designed by the power engineer in the early stage of project planning. At the same time, [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":7015,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[277],"tags":[],"class_list":["post-7014","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.daelimtransformer.com\/pl\/wp-json\/wp\/v2\/posts\/7014","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.daelimtransformer.com\/pl\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.daelimtransformer.com\/pl\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.daelimtransformer.com\/pl\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.daelimtransformer.com\/pl\/wp-json\/wp\/v2\/comments?post=7014"}],"version-history":[{"count":0,"href":"https:\/\/www.daelimtransformer.com\/pl\/wp-json\/wp\/v2\/posts\/7014\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.daelimtransformer.com\/pl\/wp-json\/wp\/v2\/media\/7015"}],"wp:attachment":[{"href":"https:\/\/www.daelimtransformer.com\/pl\/wp-json\/wp\/v2\/media?parent=7014"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.daelimtransformer.com\/pl\/wp-json\/wp\/v2\/categories?post=7014"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.daelimtransformer.com\/pl\/wp-json\/wp\/v2\/tags?post=7014"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}