{"id":7350,"date":"2026-01-05T08:29:01","date_gmt":"2026-01-05T08:29:01","guid":{"rendered":"https:\/\/daelimtransformer.com\/?p=7350"},"modified":"2026-03-10T06:57:51","modified_gmt":"2026-03-10T06:57:51","slug":"pad-mounted-transformer-csa-c227-4-national-standard-of-canada","status":"publish","type":"post","link":"https:\/\/www.daelimtransformer.com\/pl\/csa-c2274-national-standard-of-canada.html","title":{"rendered":"Transformator Montowany na P\u0142ycie - Kanadyjska Norma Narodowa CSA C227.4"},"content":{"rendered":"<div id=\"contentMain\" class=\"article-content\">\n<p class=\"p\" style=\"margin-top: 0.0000pt; margin-bottom: 0.0000pt; text-align: justify; margin: 5pt 0pt;\" align=\"justify\"><img decoding=\"async\" style=\"width: 760px; height: 570px;\" title=\"csa c227.4\" src=\"\/media\/115\/CSA-C227.4.webp\" alt=\"csa c227.4\" \/><\/p>\n<p align=\"justify\">Transformatorzy s\u0105 niezb\u0119dni w naszym codziennym \u017cyciu, poniewa\u017c przekszta\u0142caj\u0105 pr\u0105d przemienny na pr\u0105d sta\u0142y i transportuj\u0105 energi\u0119 elektryczn\u0105 do Twoich urz\u0105dze\u0144, sprz\u0119tu i innych, aby zapewni\u0107 ich trwa\u0142o\u015b\u0107 i wydajno\u015b\u0107. W zwi\u0105zku z tym, jako nabywca i producent transformator\u00f3w, powiniene\u015b by\u0107 zaznajomiony z lokalnymi wymaganiami projektowymi i normami transformator\u00f3w. Artyku\u0142 ten przedstawia standardy transformator\u00f3w w Kanadzie. <a href=\"https:\/\/www.csagroup.org\/store\/product\/CSA%20C227.4:21\/\" rel=\"noopener\">CSA C227.4<\/a>, transformator montowany na p\u0142ycie poni\u017cej 3000kVA.<\/p>\n<p class=\"p\" style=\"margin-top: 0.0000pt; margin-bottom: 0.0000pt; text-align: justify; margin: 5pt 0pt;\" align=\"justify\"><a href=\"https:\/\/www.daelimtransformer.com\/pl\/500-kva-pad-mounted-transformer.html\" target=\"_blank\" rel=\"noopener\"><img decoding=\"async\" style=\"width: 300px; height: 300px;\" src=\"\/media\/115\/500kva-transformers.jpg\" \/><\/a><a href=\"https:\/\/www.daelimtransformer.com\/pl\/1000-kva-pad-mounted-transformer.html\" target=\"_blank\" rel=\"noopener\"><img decoding=\"async\" style=\"width: 300px; height: 300px;\" src=\"\/media\/115\/1000kva-transformers.JPG\" \/><\/a><\/p>\n<p class=\"p\" style=\"margin-top: 0.0000pt; margin-bottom: 0.0000pt; text-align: justify; margin: 5pt 0pt;\" align=\"justify\"><a href=\"https:\/\/www.daelimtransformer.com\/pl\/2000-kva-pad-mounted-transformer.html\" target=\"_blank\" rel=\"noopener\"><img decoding=\"async\" style=\"width: 300px; height: 300px;\" src=\"\/media\/115\/2000kva-transformers.jpg\" \/><\/a><a href=\"https:\/\/www.daelimtransformer.com\/pl\/2500-kva-pad-mounted-transformer.html\" target=\"_blank\" rel=\"noopener\"><img decoding=\"async\" style=\"width: 300px; height: 300px;\" src=\"\/media\/115\/2500kva-transformers.jpg\" \/><\/a><\/p>\n<h2 style=\"margin-top: 18.0000pt; margin-bottom: 6.0000pt; text-align: left;\"><span class=\"ez-toc-section\" id=\"What_Is_CSA_C2274\"><\/span><span style=\"font-size: 18pt;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"font-weight: bold;\"><b><span style=\"font-size: 16.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #000000;\"><span style=\"font-weight: bold;\"><span style=\"font-style: normal;\"><a id=\"1\" name=\"1\"><\/a>Czym jest CSA C227.4?<\/span><\/span><\/span><\/span><\/span><\/b><\/span><\/span><\/span><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p class=\"p\" style=\"margin-top: 0.0000pt; margin-bottom: 0.0000pt; text-align: justify; margin: 5pt 0pt;\" align=\"justify\"><span style=\"font-size: 12pt;\"><span style=\"text-justify: inter-ideograph;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #000000;\"><span style=\"font-style: normal;\">Standard CSA C227.4 to standard, kt\u00f3ry wskazuje szczeg\u00f3\u0142owe wymagania dla transformator\u00f3w rozdzielczych zasilanych z trzech faz, <\/span><\/span><\/span><\/span><a href=\"https:\/\/www.daelimtransformer.com\/pl\/three-phase-pad-mounted-transformer-daelim.html\" target=\"_blank\" rel=\"noopener\"><span style=\"color: #9b59b6;\"><b><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"font-weight: bold;\"><span style=\"font-style: normal;\">montowanych na p\u0142ycie.<\/span><\/span><\/span><\/span><\/b><\/span><\/a><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #000000;\"><span style=\"font-style: normal;\">. Te transformatory sk\u0142adaj\u0105 si\u0119 z transformatora i komory wej\u015bciowej z kablem z urz\u0105dzeniami do oddzielnych izolowanych z\u0142\u0105czy wysokiego napi\u0119cia. Transformatory te s\u0105 zaprojektowane do pracy g\u0142\u00f3wnie przez przedsi\u0119biorstwa energetyczne w systemach rozdzia\u0142u podziemnego na trzy fazy.<\/span><\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p class=\"p\" style=\"margin-top: 0.0000pt; margin-bottom: 0.0000pt; text-align: justify; margin: 5pt 0pt;\" align=\"justify\"><img decoding=\"async\" style=\"width: 700px; height: 436px;\" title=\"Transformator montowany na p\u0142ycie CSA C227.4\" src=\"\/media\/115\/CSA-C227-4-pad-mounted-transformer.webp\" alt=\"Transformator montowany na p\u0142ycie CSA C227.4\" \/><\/p>\n<p style=\"text-align: left; margin: 0pt 0pt 0.0001pt;\"><span style=\"color: #27ae60;\"><span style=\"font-size: 18px;\"><strong>Dowiedz si\u0119 wi\u0119cej:\u00a0<\/strong><\/span><\/span><span style=\"font-size: 18px;\"><strong><a href=\"https:\/\/www.daelimtransformer.com\/pl\/3-phase-pad-mounted-transformer.html\" target=\"_blank\" rel=\"noopener\"><span style=\"color: #d35400;\">Transformator pad montowany 3-fazowy - Daelim Belefic<\/span><\/a><\/strong><\/span><\/p>\n<p align=\"justify\">Na przyk\u0142ad, je\u015bli pracujesz w sektorze spawalniczym, wiesz, \u017ce spawanie jest kluczow\u0105 technik\u0105 \u0142\u0105czenia stosowan\u0105 w produkcji transformator\u00f3w rozdzielczych. Konieczne jest przestrzeganie normy CSA C227.4, aby zapewni\u0107 jako\u015b\u0107 spaw\u00f3w i bezpiecze\u0144stwo u\u017cytkownik\u00f3w transformator\u00f3w rozdzielczych. Norma ta okre\u015bla pewne wymagania dotycz\u0105ce projektowania i budowy transformator\u00f3w rozdzielczych, maj\u0105c na uwadze, \u017ce ludzie korzystaj\u0105 z tych transformator\u00f3w.<\/p>\n<h2 style=\"margin-top: 18.0000pt; margin-bottom: 6.0000pt; text-align: left;\"><span class=\"ez-toc-section\" id=\"What_Is_A_Pad_Mounted_Transformer_And_Its_Features\"><\/span><span style=\"font-size: 18pt;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"font-weight: bold;\"><b><span style=\"font-size: 16.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #000000;\"><span style=\"font-weight: bold;\"><span style=\"font-style: normal;\"><a id=\"2\" name=\"2\"><\/a>Czym jest transformator zamontowany na podstawie i jakie ma cechy?\u00a0<\/span><\/span><\/span><\/span><\/span><\/b><\/span><\/span><\/span><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p align=\"justify\">Transformatorzy montowani na p\u0142ycie lub pad-mounted to stalowe szafy stosowane do dystrybucji energii elektrycznej. S\u0105 one r\u00f3wnie\u017c w pe\u0142ni na\u0142adowane, a punkty s\u0105 bezpiecznie zamkni\u0119te w uziemionej metalowej obudowie. Linia dystrybucji energii elektrycznej wprowadza istotne transformatory w miejscach odbioru us\u0142ug, aby zmniejszy\u0107 napi\u0119cie pierwotne w linii i napi\u0119cie wt\u00f3rne dla dostawcy energii.<\/p>\n<p align=\"justify\">Transformatory zaprojektowane do umieszczania na p\u0142ycie mog\u0105 mie\u0107 moc od 15 do 5000 kVA i zazwyczaj zawieraj\u0105 wbudowane bezpieczniki oraz wy\u0142\u0105czniki. Aby u\u0142atwi\u0107 naprawy i konserwacj\u0119, linie zasilaj\u0105ce mog\u0105 by\u0107 po\u0142\u0105czone z z\u0142\u0105czami \u0142okciowymi, kt\u00f3re mo\u017cna aktywowa\u0107 za pomoc\u0105 gor\u0105cego narz\u0119dzia.<\/p>\n<p align=\"justify\"><strong>Przeczytaj wi\u0119cej:\u00a0<a href=\"https:\/\/www.daelimtransformer.com\/pl\/5000kva-transformer-daelim.html\" target=\"_blank\" rel=\"noopener\">Ostateczny przewodnik FAQ 5000kVA Transformatory-Daelim<\/a><\/strong><\/p>\n<p align=\"justify\">Transformatory montowane na p\u0142ycie maj\u0105 wiele zalet w por\u00f3wnaniu do transformator\u00f3w stacyjnych pod wzgl\u0119dem funkcjonalno\u015bci.<\/p>\n<p align=\"justify\"><strong>Oto niekt\u00f3re z nich:<\/strong><\/p>\n<p align=\"justify\">\u2022 Zmniejszona potrzeba powierzchni i koszt\u00f3w instalacji<\/p>\n<p align=\"justify\">\u2022 Zmniejszona potrzeba powierzchni i koszt\u00f3w instalacji<\/p>\n<p align=\"justify\">\u2022 Poprawa estetyki i bezpiecze\u0144stwa<\/p>\n<p align=\"justify\">\u2022 Poprawiona efektywno\u015b\u0107 wykorzystania ziemi<\/p>\n<p align=\"justify\">Transformatory montowane na p\u0142ycie maj\u0105 mniejsze wymagania co do przestrzeni i koszt\u00f3w ni\u017c stacje transformatorowe przy tej samej ilo\u015bci dostarczanej energii. Poniewa\u017c transformatory montowane na p\u0142ycie s\u0105 autonomiczne i odporne na manipulacje, mo\u017cna je zainstalowa\u0107 w niezabezpieczonych obszarach bez konieczno\u015bci budowy kosztownego ogrodzenia lub obudowy. \u0141atwy dost\u0119p u\u0142atwia tak\u017ce konserwacj\u0119.<\/p>\n<p><span style=\"font-size: 18px;\"><span class=\"p\" style=\"margin-bottom: 0.0000pt; margin-top: 0.0000pt; margin: 5pt 0pt; text-align: justify;\"><span style=\"color: #27ae60;\"><span style=\"font-family: Calibri;\"><span style=\"font-style: normal;\"><strong>Dowiedz si\u0119 wi\u0119cej: <\/strong><\/span><\/span><\/span><span style=\"font-family: Calibri;\"><span style=\"font-style: normal;\"><strong><a href=\"https:\/\/www.daelimtransformer.com\/pl\/2500-kva-pad-mounted-transformer.html\" target=\"_blank\" rel=\"noopener\"><span style=\"color: #d35400;\">Transformator na pod\u0142o\u017cu 2500 kVA<\/span><\/a><\/strong><\/span><\/span><\/span><\/span><\/p>\n<h2 style=\"margin-top: 0.0000pt; margin-bottom: 6.0000pt; text-align: justify;\" align=\"justify\"><span class=\"ez-toc-section\" id=\"What_Are_Various_Version_Of_CSA_C2274_Scope_Or_Standard\"><\/span><span style=\"font-size: 18pt;\"><span style=\"text-justify: inter-ideograph;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"font-weight: bold;\"><b><span style=\"font-size: 16.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #000000;\"><span style=\"font-weight: bold;\"><span style=\"font-style: normal;\"><a id=\"3\" name=\"3\"><\/a>Jakie s\u0105 r\u00f3\u017cne wersje zakresu lub normy CSA C227.4?<\/span><\/span><\/span><\/span><\/span><\/b><\/span><\/span><\/span><\/span><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Tempo w jakim standardy ewoluuj\u0105 jest znacznie wi\u0119ksze, ni\u017c mo\u017cesz si\u0119 spodziewa\u0107.<\/p>\n<p>Ponadto, aby okre\u015bli\u0107 r\u00f3\u017cnice pomi\u0119dzy wersjami z ka\u017cdego roku oraz ewolucj\u0119 normy CSA C227.4 na przestrzeni czasu. Oto zakres i wymagania dla ka\u017cdej wersji, zaczynaj\u0105c od CSA C277.4-06.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"CSA-C2274-06\"><\/span><a id=\"3.1\" name=\"3.1\"><\/a>CSA-C227.4-06<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p><strong>Zakres<\/strong>:<\/p>\n<p align=\"justify\">Niniejszy standard okre\u015bla kryteria dla 3-fazowego, montowanego na p\u0142ycie transformatora rozdzielczego, kt\u00f3ry sk\u0142ada si\u0119 z transformatora i komory wej\u015bciowej kablowej z przewidzianym oddzielnymi izolowanymi z\u0142\u0105czami wysokiego napi\u0119cia, i jest g\u0142\u00f3wnie zaprojektowany do u\u017cytku przez firmy energetyczne na wielu systemach rozdzia\u0142u podziemnego o napi\u0119ciach pierwotnych.<\/p>\n<p align=\"justify\"><strong>Standard<\/strong>:<\/p>\n<p class=\"p\" style=\"margin-top: 0.0000pt; margin-bottom: 0.0000pt; text-align: justify; margin: 5pt 0pt;\" align=\"justify\"><span style=\"font-size: 12pt;\"><span style=\"text-justify: inter-ideograph;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #000000;\"><span style=\"font-style: normal;\">Jego zastosowania to trzy-fazowe, montowane na p\u0142ycie, 60Hz, transformator\u00f3w rozdzielczych nape\u0142nionych ciecz\u0105 o mocy do 3000 kVA. Ponadto, jego izolacja wynosi 18kV lub mniej, a z\u0142\u0105cza wysokiego napi\u0119cia s\u0105 oddzielnie izolowane. Transformatory mog\u0105 by\u0107 montowane na zewn\u0105trz na \u0142awach bez konieczno\u015bci dodatkowych zabezpiecze\u0144.<\/span><\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p style=\"text-align: left; margin: 0pt 0pt 0.0001pt;\"><span style=\"color: #27ae60;\"><span style=\"font-size: 18px;\"><strong>Wypr\u00f3buj za darmo:\u00a0<\/strong><\/span><\/span><span style=\"font-size: 18px;\"><strong><a href=\"https:\/\/www.daelimtransformer.com\/pl\/3000kva-transformer.html\" target=\"_blank\" rel=\"noopener\"><span style=\"color: #c0392b;\">Jak zakupi\u0107 transformator 3000kVA w USA i Kanadzie?<\/span><\/a><\/strong><\/span><\/p>\n<p class=\"p\" style=\"margin-top: 0.0000pt; margin-bottom: 0.0000pt; text-align: justify; margin: 5pt 0pt;\" align=\"justify\"><span style=\"font-size: 12pt;\"><span style=\"text-justify: inter-ideograph;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #000000;\"><span style=\"font-style: normal;\">Zawiera warto\u015bci napi\u0119cia wyra\u017cone w kVA, protoko\u0142y testowe oraz w\u0142a\u015bciwo\u015bci mechaniczne. Wzrost temperatury, pojemno\u015b\u0107 obci\u0105\u017ceniowa, poziom czystego ha\u0142asu, napi\u0119cie efektu radiowego oraz efektywno\u015b\u0107 energetyczna stanowi\u0105 jego parametry eksploatacyjne.<\/span><\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p class=\"p\" style=\"margin-top: 0.0000pt; margin-bottom: 0.0000pt; text-align: justify; margin: 5pt 0pt;\" align=\"justify\"><span style=\"font-size: 12pt;\"><span style=\"text-justify: inter-ideograph;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #000000;\"><span style=\"font-style: normal;\">Kiedy ten sprz\u0119t jest zaprojektowany do u\u017cycia przez podmiot inny ni\u017c dostawca energii elektrycznej, nabywca musi zapewni\u0107, \u017ce jednostka spe\u0142nia standardy w\u0142a\u015bciwego organu inspekcji elektrycznej.<\/span><\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p class=\"p\" style=\"margin-top: 0.0000pt; margin-bottom: 0.0000pt; text-align: justify; margin: 5pt 0pt;\" align=\"justify\"><span style=\"font-size: 12pt;\"><span style=\"text-justify: inter-ideograph;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #000000;\"><span style=\"font-style: normal;\">Ten standard pozwala na wymian\u0119 jednostki zamontowanej na p\u0142ycie, z frontem martwym, na jednostk\u0119 o tych samych podstawowych wymiarach fizycznych od r\u00f3\u017cnych producent\u00f3w bez modyfikacji przewod\u00f3w lub p\u0142yty. Standard okre\u015bla wymagane minimalne i maksymalne wymiary dla konfiguracji zacisk\u00f3w u\u017cywanych w systemach promieniowych i p\u0119tlowych.<\/span><\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p class=\"p\" style=\"margin-top: 0.0000pt; margin-bottom: 0.0000pt; text-align: justify; margin: 5pt 0pt;\" align=\"justify\"><span style=\"color: #27ae60;\"><span style=\"font-size: 18px;\"><strong><span style=\"font-family: Calibri;\"><span style=\"font-family: Arial;\"><span style=\"font-style: normal;\">Wypr\u00f3buj za darmo: <\/span><\/span><\/span><\/strong><\/span><\/span><span style=\"font-size: 18px;\"><strong><span style=\"font-family: Calibri;\"><span style=\"font-family: Arial;\"><span style=\"font-style: normal;\"><a href=\"https:\/\/www.daelimtransformer.com\/pl\/live-front-pad-mounted-transformers-under-csa-c227.5.html\"><span style=\"color: #c0392b;\">Norma CSA C227.5<\/span><\/a><\/span><\/span><\/span><\/strong><\/span><\/p>\n<h3 style=\"margin-top: 0.0000pt; margin-bottom: 0.0000pt; padding: 0pt 0pt 0pt 0pt; text-align: left;\"><span class=\"ez-toc-section\" id=\"CSA-C2274-06_2nd_Update\"><\/span><span style=\"font-size: 13.5pt;\"><span style=\"background: #ffffff;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"font-weight: bold;\"><b><span style=\"font-size: 14.0000pt;\"><span style=\"background: #ffffff;\"><span style=\"font-family: Arial;\"><span style=\"color: #434343;\"><span style=\"font-weight: bold;\"><span style=\"font-style: normal;\"><a id=\"3.2\" name=\"3.2\"><\/a>CSA-C227.4-06 2. aktualizacja<\/span><\/span><\/span><\/span><\/span><\/span><\/b><\/span><\/span><\/span><\/span><span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p class=\"p\" style=\"margin-top: 0.0000pt; margin-bottom: 0.0000pt; margin: 5pt 0pt; text-align: left;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><b><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #000000;\"><span style=\"font-weight: bold;\"><span style=\"font-style: normal;\">Zakres:<\/span><\/span><\/span><\/span><\/span><\/b><\/span><\/span><\/p>\n<p class=\"p\" style=\"margin-top: 0.0000pt; margin-bottom: 0.0000pt; margin: 5pt 0pt; text-align: left;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #000000;\"><span style=\"font-style: normal;\">Transformatory dystrybucyjne tr\u00f3jfazowe zamontowane na p\u0142ycie, przeznaczone g\u0142\u00f3wnie dla dostawc\u00f3w energii elektrycznej w systemach dystrybucji podziemnej tr\u00f3jfazowej z napi\u0119ciami pierwotnymi okre\u015blonymi w tym standardzie. Tego typu transformator sk\u0142ada si\u0119 z kom\u00f3r wej\u015bciowych kablowych wykorzystuj\u0105cych oddzielne izolowane \u0142\u0105cza wysokiego napi\u0119cia.\u00a0<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p class=\"p\" style=\"margin-top: 0.0000pt; margin-bottom: 0.0000pt; margin: 5pt 0pt; text-align: left;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><b><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #000000;\"><span style=\"font-weight: bold;\"><span style=\"font-style: normal;\">Standard:<\/span><\/span><\/span><\/span><\/span><\/b><\/span><\/span><\/p>\n<p class=\"p\" style=\"margin-top: 0.0000pt; margin-bottom: 0.0000pt; margin: 5pt 0pt; text-align: left;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #000000;\"><span style=\"font-style: normal;\">Dotyczy transformator\u00f3w dystrybucyjnych tr\u00f3jfazowych, nape\u0142nionych ciecz\u0105, montowanych na p\u0142ycie, o mocy 3000 kVA lub mniejszej, z klasyfikacj\u0105 izolacyjn\u0105 18kV lub mniejsz\u0105 oraz oddzielnymi izolowanymi \u0142\u0105czami wysokiego napi\u0119cia. Transformatory mog\u0105 by\u0107 montowane na zewn\u0105trz na p\u0142ytach bez potrzeby dodatkowych os\u0142on ochronnych.<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p class=\"p\" style=\"margin-top: 0.0000pt; margin-bottom: 0.0000pt; text-align: justify; margin: 5pt 0pt;\" align=\"justify\"><span style=\"font-size: 12pt;\"><span style=\"text-justify: inter-ideograph;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #000000;\"><span style=\"font-style: normal;\">W tej Normie zawarte s\u0105 konkretne cechy mechaniczne, a tak\u017ce techniki testowe oraz napi\u0119cie i oceny w kV\u2022A. Efektywno\u015b\u0107 energetyczna (mierzone w odniesieniu do CAN\/CSA-C802.1), wzrost temperatury, zdolno\u015bci obci\u0105\u017ceniowe, poziom ha\u0142asu oraz napi\u0119cie efektu radiowego s\u0105 zawarte w parametrach wydajno\u015bci Normy (RIV).<\/span><\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p class=\"p\" style=\"margin-top: 0.0000pt; margin-bottom: 0.0000pt; margin: 5pt 0pt; text-align: left;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #000000;\"><span style=\"font-style: normal;\">Dzi\u0119ki temu standardowi mo\u017cna wymieni\u0107 jednostk\u0119 zamontowan\u0105 na p\u0142ycie, z frontem martwym, na jednostk\u0119 wyprodukowan\u0105 przez innego producenta, niezale\u017cnie od tego, czy przewody lub p\u0142yta zosta\u0142y w jakikolwiek spos\u00f3b zmienione. Uk\u0142ady zacisk\u00f3w, w tym minimalne i szczeg\u00f3lne wymiary, s\u0105 obj\u0119te tym standardem dla system\u00f3w promieniowych i p\u0119tlowych.<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p class=\"p\" style=\"margin-top: 0.0000pt; margin-bottom: 0.0000pt; margin: 5pt 0pt; text-align: left;\"><span style=\"color: #27ae60;\"><span style=\"font-size: 18px;\"><strong><span style=\"font-family: Calibri;\"><span style=\"font-family: Arial;\"><span style=\"font-style: normal;\">Zdob\u0105d\u017a to teraz: <\/span><\/span><\/span><\/strong><\/span><\/span><span style=\"font-size: 18px;\"><strong><span style=\"font-family: Calibri;\"><span style=\"font-family: Arial;\"><span style=\"font-style: normal;\"><a href=\"https:\/\/www.daelimtransformer.com\/pl\/dead-front-transformer.html\" target=\"_blank\" rel=\"noopener\"><span style=\"color: #c0392b;\">Ostateczny przewodnik po transformatorach z frontem martwym<\/span><\/a><\/span><\/span><\/span><\/strong><\/span><\/p>\n<h3 style=\"margin-top: 0.0000pt; margin-bottom: 0.0000pt; padding: 0pt 0pt 0pt 0pt; text-align: left;\"><\/h3>\n<h3 style=\"margin-top: 0.0000pt; margin-bottom: 0.0000pt; padding: 0pt 0pt 0pt 0pt; text-align: left;\"><span class=\"ez-toc-section\" id=\"CSA_C2274-21_The_Newest_Update\"><\/span><span style=\"font-size: 13.5pt;\"><span style=\"background: #ffffff;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"font-weight: bold;\"><b><span style=\"font-size: 14.0000pt;\"><span style=\"background: #ffffff;\"><span style=\"font-family: Arial;\"><span style=\"color: #434343;\"><span style=\"font-weight: bold;\"><span style=\"font-style: normal;\"><a id=\"3.3\" name=\"3.3\"><\/a>CSA C227.4-21 (naj\u015bwie\u017csza aktualizacja)<\/span><\/span><\/span><\/span><\/span><\/span><\/b><\/span><\/span><\/span><\/span><span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p class=\"p\" style=\"margin-top: 0.0000pt; margin-bottom: 0.0000pt; margin: 5pt 0pt; text-align: left;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><b><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #000000;\"><span style=\"font-weight: bold;\"><span style=\"font-style: normal;\">Zakres:\u00a0<\/span><\/span><\/span><\/span><\/span><\/b><\/span><\/span><\/p>\n<p class=\"p\" style=\"margin-top: 0.0000pt; margin-bottom: 0.0000pt; text-align: justify; margin: 5pt 0pt;\" align=\"justify\"><span style=\"font-size: 12pt;\"><span style=\"text-justify: inter-ideograph;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #000000;\"><span style=\"font-style: normal;\">Celem tego standardu jest zdefiniowanie specyfikacji dla tr\u00f3jfazowych, zamontowanych na p\u0142ycie transformator\u00f3w dystrybucyjnych. Te transformatory sk\u0142adaj\u0105 si\u0119 z transformatora i komory wej\u015bciowej kablowej z wymaganiem oddzielnych i wyra\u017anych izolowanych \u0142\u0105czy wysokiego napi\u0119cia. Te transformatory s\u0105 zaprojektowane do korzystania z u\u017cyteczno\u015bci pyroelectric z operacj\u0105 na wielu sieciach dystrybucji podziemnej o napi\u0119ciach pierwotnych.<\/span><\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p class=\"p\" style=\"margin-top: 0.0000pt; margin-bottom: 0.0000pt; text-align: justify; margin: 5pt 0pt;\" align=\"justify\"><span style=\"font-size: 12pt;\"><span style=\"background: #ffffff;\"><span style=\"text-justify: inter-ideograph;\"><span style=\"font-family: Calibri;\">\u00a0<span style=\"color: #27ae60;\"><span style=\"font-size: 18px;\"><strong>Mo\u017cesz by\u0107 zainteresowany: <a href=\"https:\/\/www.daelimtransformer.com\/pl\/csa-c227-3-for-single-phase-pad-mounted-transformer.html\">Norma CSA C227.3<\/a><\/strong><\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p class=\"p\" style=\"margin-top: 0.0000pt; margin-bottom: 0.0000pt; text-align: justify; margin: 5pt 0pt;\" align=\"justify\"><span style=\"font-size: 12pt;\"><span style=\"background: #ffffff;\"><span style=\"text-justify: inter-ideograph;\"><span style=\"font-family: Calibri;\"><b><span style=\"font-size: 11.0000pt;\"><span style=\"background: #ffffff;\"><span style=\"font-family: Arial;\"><span style=\"color: #000000;\"><span style=\"font-weight: bold;\"><span style=\"font-style: normal;\">Standard:\u00a0<\/span><\/span><\/span><\/span><\/span><\/span><\/b><\/span><\/span><\/span><\/span><\/p>\n<p class=\"p\" style=\"margin-top: 0.0000pt; margin-bottom: 0.0000pt; text-align: justify; margin: 5pt 0pt;\" align=\"justify\"><span style=\"font-size: 12pt;\"><span style=\"background: #ffffff;\"><span style=\"text-justify: inter-ideograph;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"background: #ffffff;\"><span style=\"font-family: Arial;\"><span style=\"color: #000000;\"><span style=\"font-style: normal;\">Ten standard dotyczy tr\u00f3jfazowych transformator\u00f3w dystrybucyjnych, kt\u00f3re dzia\u0142aj\u0105 przy 60 hercach, maj\u0105 monta\u017c na p\u0142ycie, s\u0105 nape\u0142nione ciecz\u0105, maj\u0105 klasyfikacj\u0119 3000 kVA lub mniejsz\u0105, pracuj\u0105 w systemach o nominalnym napi\u0119ciu do 34,5 kV oraz maj\u0105 oddzielne izolowane \u0142\u0105cza wysokiego napi\u0119cia. Transformatory mog\u0105 by\u0107 montowane na zewn\u0105trz na p\u0142ytach bez potrzeby dodatkowych os\u0142on ochronnych, poniewa\u017c s\u0105 odporne na dzia\u0142anie warunk\u00f3w atmosferycznych.<\/span><\/span><\/span><\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p style=\"text-align: left; margin: 0pt 0pt 0.0001pt;\"><span style=\"color: #27ae60;\"><span style=\"font-size: 18px;\"><strong>Mo\u017cesz by\u0107 zainteresowany: <\/strong><\/span><\/span><span style=\"font-size: 18px;\"><strong><a href=\"https:\/\/www.daelimtransformer.com\/pl\/34.5-kv-transformer.html\" target=\"_blank\" rel=\"noopener\"><span style=\"color: #d35400;\">Czy chcesz dowiedzie\u0107 si\u0119 wi\u0119cej o transformatorze 34,5 kV?<\/span><\/a><\/strong><\/span><\/p>\n<p class=\"p\" style=\"margin-top: 0.0000pt; margin-bottom: 0.0000pt; text-align: justify; margin: 5pt 0pt;\" align=\"justify\"><span style=\"font-size: 12pt;\"><span style=\"text-justify: inter-ideograph;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #000000;\"><span style=\"font-style: normal;\">Ten standard zapewnia specyficzne cechy mechaniczne, protoko\u0142y testowe, napi\u0119cie i klasyfikacj\u0119 kVA. Standard ten zawiera tak\u017ce nast\u0119puj\u0105ce cechy: efektywno\u015b\u0107 energetyczna (zgodnie z <a href=\"https:\/\/www.daelimtransformer.com\/pl\/csa-c802:-minimum-efficiency-values-for-power-transformers.html\">CAN\/CSA-C802.1<\/a>), wzrost temperatury, zdolno\u015b\u0107 \u0142adowania, poziom ha\u0142asu akustycznego oraz napi\u0119cie wp\u0142ywu bezprzewodowego (RIV).<\/span><\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p class=\"p\" style=\"margin-top: 0.0000pt; margin-bottom: 0.0000pt; text-align: justify; margin: 5pt 0pt;\" align=\"justify\"><span style=\"font-size: 12pt;\"><span style=\"text-justify: inter-ideograph;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #000000;\"><span style=\"font-style: normal;\">Ponadto, odpowiedzialno\u015bci\u0105 nabywcy jest sprawdzenie, czy jednostka spe\u0142nia normy odpowiedniego organu inspekcji elektrycznej, je\u015bli jest u\u017cywana przez kogokolwiek innego ni\u017c publiczny dostawca.<\/span><\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p class=\"p\" style=\"margin-top: 0.0000pt; margin-bottom: 0.0000pt; text-align: justify; margin: 5pt 0pt;\" align=\"justify\"><span style=\"font-size: 12pt;\"><span style=\"text-justify: inter-ideograph;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #000000;\"><span style=\"font-style: normal;\">Norma przewiduje wymian\u0119 jednostki montowanej na p\u0142ycie, jednostki z zamkni\u0119t\u0105 przedni\u0105 cz\u0119\u015bci\u0105 na inn\u0105 o tym samym podstawowym rozmiarze fizycznym od r\u00f3\u017cnych producent\u00f3w dla transformator\u00f3w o klasie mniejszej ni\u017c 125 kV BIL, bez modyfikacji przewod\u00f3w pad\u00f3w. Dotyczy to tak\u017ce uk\u0142ad\u00f3w przy\u0142\u0105czy dla system\u00f3w zasilania w p\u0119tli i promieniowych oraz innych minimalnych wymiar\u00f3w i specyfikacji.<\/span><\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<h2 style=\"margin-top: 18.0000pt; margin-bottom: 6.0000pt; text-align: justify;\" align=\"justify\"><span class=\"ez-toc-section\" id=\"Major_Changes_In_The_New_CSA_C2274_Standard\"><\/span><span style=\"font-size: 18pt;\"><span style=\"text-justify: inter-ideograph;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"font-weight: bold;\"><b><span style=\"font-size: 16.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #000000;\"><span style=\"font-weight: bold;\"><span style=\"font-style: normal;\"><a id=\"4\" name=\"4\"><\/a>G\u0142\u00f3wne zmiany w nowej normie CSA C227.4<\/span><\/span><\/span><\/span><\/span><\/b><\/span><\/span><\/span><\/span><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p class=\"p\" style=\"margin-top: 0.0000pt; margin-bottom: 0.0000pt; text-align: justify; margin: 5pt 0pt;\" align=\"justify\"><span style=\"font-size: 12pt;\"><span style=\"text-justify: inter-ideograph;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #000000;\"><span style=\"font-style: normal;\">Poni\u017cej znajduje si\u0119 lista istotnych dodatk\u00f3w i zmian wprowadzonych w tej edycji:<\/span><\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<ul>\n<li style=\"margin-top: 5.0000pt; margin-bottom: 5.0000pt; margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 12pt;\"><span style=\"text-justify: inter-ideograph;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #000000;\"><span style=\"font-style: normal;\">Poszerzono zakres, aby uwzgl\u0119dni\u0107 systemy o nominalnych napi\u0119ciach 34,5 kV, a tak\u017ce zrezygnowano z termin\u00f3w kategoria izolacyjna i preferowane napi\u0119cia.;<\/span><\/span><\/span><\/span><\/span><\/span><\/span><\/li>\n<li style=\"margin-top: 5.0000pt; margin-bottom: 5.0000pt; margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 12pt;\"><span style=\"text-justify: inter-ideograph;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #000000;\"><span style=\"font-style: normal;\">Referencje, kt\u00f3re zosta\u0142y zaktualizowane w zgodno\u015bci z innymi standardami bran\u017cowymi;<\/span><\/span><\/span><\/span><\/span><\/span><\/span><\/li>\n<li style=\"margin-top: 5.0000pt; margin-bottom: 5.0000pt; margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 12pt;\"><span style=\"text-justify: inter-ideograph;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #000000;\"><span style=\"font-style: normal;\">Wyja\u015bnione wymagania dotycz\u0105ce odczep\u00f3w napi\u0119cia bez obci\u0105\u017cenia oraz dodano uwagi wyja\u015bniaj\u0105ce dotycz\u0105ce transformator\u00f3w dwunapi\u0119ciowych, kt\u00f3re posiadaj\u0105 odczepy;<\/span><\/span><\/span><\/span><\/span><\/span><\/span><\/li>\n<li style=\"margin-top: 5.0000pt; margin-bottom: 5.0000pt; margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 12pt;\"><span style=\"text-justify: inter-ideograph;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #000000;\"><span style=\"font-style: normal;\">Dodatkowe wymagania dotycz\u0105ce oznacze\u0144 ca\u0142kowicie dobrowolnego w\u0142\u0105cznika obci\u0105\u017cenia, poniewa\u017c stare referencje IEEE nie s\u0105 ju\u017c wa\u017cne;<\/span><\/span><\/span><\/span><\/span><\/span><\/span><\/li>\n<li style=\"margin-top: 5.0000pt; margin-bottom: 5.0000pt; margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 12pt;\"><span style=\"text-justify: inter-ideograph;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #000000;\"><span style=\"font-style: normal;\">Warunki zosta\u0142y zmienione i wyja\u015bnione w odniesieniu do systemu z dwoma bezpiecznikami, a tabele zawieraj\u0105ce numery cz\u0119\u015bci specyficzne dla producenta zosta\u0142y usuni\u0119te;<\/span><\/span><\/span><\/span><\/span><\/span><\/span><\/li>\n<li style=\"margin-top: 5.0000pt; margin-bottom: 5.0000pt; margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 12pt;\"><span style=\"text-justify: inter-ideograph;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #000000;\"><span style=\"font-style: normal;\">Wymagania dotycz\u0105ce poprawy test\u00f3w rutynowych, aby lepiej odpowiada\u0142y standardom IEEE. Na przyk\u0142ad, straty przy braku obci\u0105\u017cenia i pr\u0105d stymuluj\u0105cy b\u0119d\u0105 obliczane na podstawie nominalnego napi\u0119cia 100%, a nie 105%;<\/span><\/span><\/span><\/span><\/span><\/span><\/span><\/li>\n<li style=\"margin-top: 5.0000pt; margin-bottom: 5.0000pt; margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 12pt;\"><span style=\"text-justify: inter-ideograph;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #000000;\"><span style=\"font-style: normal;\">Oznaczenia ostro\u017cno\u015bci nie zosta\u0142y umieszczone na wewn\u0119trznych bezpiecznikach;<\/span><\/span><\/span><\/span><\/span><\/span><\/span><\/li>\n<\/ul>\n<p class=\"p\" style=\"margin-top: 0.0000pt; margin-bottom: 0.0000pt; margin-left: 36.0000pt; text-align: justify; margin: 5pt 0pt;\" align=\"justify\"><span style=\"font-size: 12pt;\"><span style=\"text-justify: inter-ideograph;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #000000;\"><span style=\"font-style: normal;\">Jego j\u0119zyk zosta\u0142 wyja\u015bniony i rozszerzony, a teraz zawiera nowe opcje. Na przyk\u0142ad, na podstawie wiedzy i praktyk u\u017cytkownik\u00f3w, regularne testy szczelno\u015bci zosta\u0142y w\u0142\u0105czone;<\/span><\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p style=\"margin-top: 5.0000pt; margin-bottom: 5.0000pt; margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"font-size: 12pt;\"><span style=\"text-justify: inter-ideograph;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #000000;\"><span style=\"font-style: normal;\">Kontynuacja dostarczania parametr\u00f3w elektrycznych dotycz\u0105cych transformator\u00f3w, kt\u00f3re s\u0105 obj\u0119te tak\u0105 norm\u0105 i kt\u00f3re pierwotnie podano w CAN\/CSA-C2;\u00a0<\/span><\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p style=\"margin-top: 5.0000pt; margin-bottom: 5.0000pt; margin: 0pt 0pt 0.0001pt; text-align: justify;\"><span style=\"color: #27ae60;\"><span style=\"font-size: 18px;\"><strong>Czytaj dalej: <\/strong><\/span><\/span><span style=\"font-size: 18px;\"><strong><a href=\"https:\/\/www.daelimtransformer.com\/pl\/2000-kva-transformer.html\" target=\"_blank\" rel=\"noopener\"><span style=\"color: #c0392b;\">Odkrywaj\u0105c wszystko o transformatorze 2000 kVA<\/span><\/a><\/strong><\/span><\/p>\n<h2 style=\"margin-top: 18.0000pt; margin-bottom: 6.0000pt; text-align: left;\"><span class=\"ez-toc-section\" id=\"What_Are_The_Electrical_And_Mechanical_Features_Of_CSA_C2274\"><\/span><span style=\"font-size: 18pt;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"font-weight: bold;\"><b><span style=\"font-size: 16.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #000000;\"><span style=\"font-weight: bold;\"><span style=\"font-style: normal;\"><a id=\"5\" name=\"5\"><\/a>Jakie s\u0105 cechy elektryczne i mechaniczne CSA <\/span><\/span><\/span><\/span><\/span><\/b><b><span style=\"font-size: 16.0000pt;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"color: #000000;\"><span style=\"font-weight: bold;\"><span style=\"font-style: normal;\"><span style=\"font-family: Arial;\">C<\/span><\/span><\/span><\/span><\/span><\/span><\/b><b><span style=\"font-size: 16.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #000000;\"><span style=\"font-weight: bold;\"><span style=\"font-style: normal;\">227.4?<\/span><\/span><\/span><\/span><\/span><\/b><\/span><\/span><\/span><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p class=\"p\" style=\"margin-top: 0.0000pt; margin-bottom: 0.0000pt; margin: 5pt 0pt; text-align: left;\"><span style=\"font-size: 12pt;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #000000;\"><span style=\"font-style: normal;\">Transformatory powinny mie\u0107 wymiary, a ich konstrukcja powinna by\u0107 jak najbardziej minimalistyczna, aby wskazywa\u0107 akcesoria, cechy, pojemno\u015b\u0107 i szczeg\u00f3lne w\u0142a\u015bciwo\u015bci kupuj\u0105cemu.<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<h3 style=\"margin-top: 16.0000pt; margin-bottom: 4.0000pt; text-align: left;\"><span class=\"ez-toc-section\" id=\"Cable_Entry_Compartment\"><\/span><span style=\"font-size: 13.5pt;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"font-weight: bold;\"><b><span style=\"font-size: 14.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #434343;\"><span style=\"font-weight: bold;\"><span style=\"font-style: normal;\"><a id=\"5.1\" name=\"5.1\"><\/a>Komora wej\u015bciowa kablowego<\/span><\/span><\/span><\/span><\/span><\/b><\/span><\/span><\/span><span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Transformator i konfiguracja komory wej\u015bcia kablowego musz\u0105 by\u0107 zaprojektowane tak, aby urz\u0105dzenia wysokiego i niskiego napi\u0119cia by\u0142y umieszczone obok siebie na zbiorniku transformatora. Wymagana b\u0119dzie pokrywa na zawiasach, aby zapewni\u0107 dost\u0119p do komory wej\u015bcia kablowego.<\/p>\n<p align=\"justify\">Os\u0142ona i parapet musz\u0105 by\u0107 skonfigurowane tak, aby mo\u017cna by\u0142o u\u017cy\u0107 prostego zamka szyfrowego do zabezpieczenia jednostki. Nale\u017cy przestrzega\u0107 normy ANSI C57.12.28 dotycz\u0105cej funkcji blokuj\u0105cych w komorze.<\/p>\n<p align=\"justify\">Ze wzgl\u0119du na ryzyko zapiekania, \u015bruby wykonane ze stali nierdzewnej nie mog\u0105 by\u0107 u\u017cywane w gniazdach wykonanych z tego samego materia\u0142u. Niemniej jednak, \u015bruba i jej wsp\u00f3\u0142dzia\u0142aj\u0105cy mechanizm gwintowany powinny by\u0107 zamontowane w spos\u00f3b umo\u017cliwiaj\u0105cy funkcjonowanie gwint\u00f3w, mimo niewielkiego przesuni\u0119cia mi\u0119dzy osiami poszczeg\u00f3lnych cz\u0119\u015bci.<\/p>\n<p style=\"text-align: left; margin: 0pt 0pt 0.0001pt;\"><span style=\"color: #27ae60;\"><span style=\"font-size: 18px;\"><strong>Mo\u017cesz by\u0107 zainteresowany: <\/strong><\/span><\/span><span style=\"font-size: 18px;\"><strong><a href=\"https:\/\/www.daelimtransformer.com\/pl\/pad-mounted-transformer.html\"><span style=\"color: #c0392b;\">Transformator montowany na pod\u0142o\u017cu<\/span><\/a><\/strong><\/span><\/p>\n<p align=\"justify\">Ze wzgl\u0119du na ryzyko zapiekania, nie wolno mocowa\u0107 \u015brub ze stali nierdzewnej w stalowych gwintowanych gniazdach. Instalacja jednak\u017ce \u015bruby i jej gwintowanego mechanizmu wsp\u00f3\u0142dzia\u0142aj\u0105cego powinna by\u0107 zaprojektowana tak, aby uwzgl\u0119dnia\u0142a niewielkie przesuni\u0119cie mi\u0119dzy osiami poszczeg\u00f3lnych element\u00f3w, jednocze\u015bnie umo\u017cliwiaj\u0105c dzia\u0142anie gwint\u00f3w i wymagaj\u0105c ich odpowiedniego przymocowania. W szczeg\u00f3lno\u015bci, \u015bruba z pi\u0119cioma g\u0142\u00f3wkami musi by\u0107 zamkni\u0119ta, aby zapobiec zgubieniu i uszkodzeniu gwintu podczas operacji pokrywy, kt\u00f3ra polega na opuszczaniu pokrywy z ca\u0142kowicie otwartej pozycji. Minimalna odleg\u0142o\u015b\u0107 80 mm musi dzieli\u0107 \u015brodek zatrzasku od dolnej cz\u0119\u015bci progu. Maksymalna dopuszczalna wysoko\u015b\u0107 progu wynosi 150 mm.<\/p>\n<p align=\"justify\">Pokrywa musi by\u0107 w stanie otworzy\u0107 si\u0119 na minimalny k\u0105t 160 stopni. Zawiasy musz\u0105 by\u0107 wykonane z materia\u0142\u00f3w odpornych na korozj\u0119 i by\u0107 wystarczaj\u0105co solidne, aby przetrwa\u0107 trudne warunki pracy. Nale\u017cy dostarczy\u0107 urz\u0105dzenie zapobiegaj\u0105ce przypadkowemu usuni\u0119ciu pokrywy.<\/p>\n<p class=\"p\" style=\"margin-top: 0.0000pt; margin-bottom: 0.0000pt; text-align: justify; margin: 5pt 0pt;\" align=\"justify\"><span style=\"color: #27ae60;\"><span style=\"font-size: 18px;\"><strong><span style=\"font-family: Calibri;\"><span style=\"font-family: Arial;\"><span style=\"font-style: normal;\">Czytaj dalej: <\/span><\/span><\/span><\/strong><\/span><\/span><span style=\"font-size: 18px;\"><strong><span style=\"font-family: Calibri;\"><span style=\"font-family: Arial;\"><span style=\"font-style: normal;\"><a href=\"https:\/\/www.daelimtransformer.com\/pl\/13.8kv-transformer.html\" target=\"_blank\" rel=\"noopener\"><span style=\"color: #c0392b;\">Ostateczny przewodnik z najcz\u0119\u015bciej zadawanymi pytaniami na temat transformatora 13.8kV<\/span><\/a><\/span><\/span><\/span><\/strong><\/span><\/p>\n<h3 align=\"justify\"><span class=\"ez-toc-section\" id=\"Pad_Mounted_Transformer_Tank\"><\/span><a id=\"5.2\" name=\"5.2\"><\/a>Transformator montowany na p\u0142ycie<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p align=\"justify\">Podstawa transformatora musi by\u0107 skonfigurowana tak, aby dolna cz\u0119\u015b\u0107 zbiornika nie dotyka\u0142a p\u0142yty. Co najmniej jeden z trzech przecinaj\u0105cych si\u0119 g\u00f3rnych naro\u017cnik\u00f3w transformatora musi by\u0107 zaokr\u0105glony z minimalnym promieniem 25 mm. Jakiekolwiek wystaj\u0105ce kraw\u0119dzie na pokrywach, kt\u00f3re s\u0105 mechanicznie przymocowane, musz\u0105 by\u0107 zaokr\u0105glone.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Drain_Plugs_And_A_Pressure-Relief_Valve\"><\/span><a id=\"5.3\" name=\"5.3\"><\/a>Wtyki odp\u0142ywowe i zaw\u00f3r bezpiecze\u0144stwa<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p align=\"justify\">Transformator musi mie\u0107 odpowiedni\u0105 wytrzyma\u0142o\u015b\u0107 i wytrzyma\u0107 ci\u015bnienie 50 kPa bez przeciekania lub nieodwracalnej deformacji zbiornik\u00f3w, kt\u00f3re przekracza 0.5% przek\u0105tnej wymiar\u00f3w dotkni\u0119tych powierzchni. Nale\u017cy r\u00f3wnie\u017c zapewni\u0107 mechanizm uwalniaj\u0105cy ci\u015bnienie typu pull-ring.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Removing_Restrictions\"><\/span><a id=\"5.4\" name=\"5.4\"><\/a>Usuwanie ogranicze\u0144<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p align=\"justify\">Struktura jednostki musi by\u0107 przesuwana lub slide na pod\u0142o\u017cu monta\u017cowym i podnoszona na miejsce bez zak\u0142\u00f3cania wysokich lub niskich linii napi\u0119cia. Wyposa\u017cenie do podnoszenia b\u0119dzie zainstalowane na zbiorniku, podobnie jak podnoszenie transformatora zapobiega przewr\u00f3ceniu.<\/p>\n<p align=\"justify\">Wsp\u00f3\u0142czynnik bezpiecze\u0144stwa 5 zgodnie z ANSI\/IEEE C57.12.25 zosta\u0142 uwzgl\u0119dniony w wkl\u0119s\u0142ych uchwytach do podnoszenia. Minimalna g\u0142\u0119boko\u015b\u0107 uchwyt\u00f3w wynosi 0,625 cala, a ich wymiary to gwint 5\/8-11 NC. Te cztery uchwyty powinny by\u0107 zainstalowane w odleg\u0142o\u015bci 100 mm od kraw\u0119dzi zbiornika. W zestawie znajduj\u0105 si\u0119 \u015bruby 5\/8-11 NC o d\u0142ugo\u015bci 64 mm (2,50 cala).<\/p>\n<p class=\"p\" style=\"margin-top: 0.0000pt; margin-bottom: 0.0000pt; text-align: justify; margin: 5pt 0pt;\" align=\"justify\"><span style=\"color: #27ae60;\"><span style=\"font-size: 18px;\"><strong>Czytanie wi\u0119cej o <\/strong><\/span><\/span><span style=\"font-size: 18px;\"><strong><a href=\"https:\/\/www.daelimtransformer.com\/pl\/ieee-c57-standard.html\"><span style=\"color: #c0392b;\">Standard IEEE CS7<\/span><\/a><\/strong><\/span><\/p>\n<h3 align=\"justify\"><span class=\"ez-toc-section\" id=\"Insulating_liquid\"><\/span><a id=\"5.5\" name=\"5.5\"><\/a>Ciecz izolacyjna<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p align=\"justify\">Nale\u017cy stosowa\u0107 olej mineralny lub alternatywny \u015brodek izolacyjny spe\u0142niaj\u0105cy wymagania normy CAN\/CSA-C50, chyba \u017ce wskazano inaczej zgodnie z klauzul\u0105 11(q). Olej mineralny musi by\u0107 co najmniej klasy B i typu I; klasy I lub typu II s\u0105 akceptowalnymi alternatywami. Gdy transformator jest sprzedawany, jego wytrzyma\u0142o\u015b\u0107 dielektryczna musi wynosi\u0107 co najmniej 40 kV podczas testu zgodnie z ASTM D 1816 przy rozstawie elektrod 2 mm.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Transformer_Construction_And_Cooling\"><\/span><a id=\"5.6\" name=\"5.6\"><\/a>Budowa i ch\u0142odzenie transformatora<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p align=\"justify\">Wszystkie transformatory musz\u0105 by\u0107 zaprojektowane tak, aby ch\u0142odzenie odbywa\u0142o si\u0119 wy\u0142\u0105cznie przez powierzchnie zbiornika; zewn\u0119trzne urz\u0105dzenia ch\u0142odz\u0105ce, takie jak \u017cebra, ch\u0142odnice itp., s\u0105 zabronione. Ca\u0142a konstrukcja transformatora musi by\u0107 uszczelniona i pozostawa\u0107 skutecznie zamkni\u0119ta w zakresie temperatury oleju od -40 \u00b0C do +105 \u00b0C.<\/p>\n<p class=\"p\" style=\"margin-top: 0.0000pt; margin-bottom: 0.0000pt; text-align: justify; margin: 5pt 0pt;\" align=\"justify\"><span style=\"color: #27ae60;\"><span style=\"font-size: 18px;\"><strong><span style=\"font-family: Calibri;\"><span style=\"font-family: Arial;\"><span style=\"font-style: normal;\">Przeczytaj m\u00f3j artyku\u0142 na temat <\/span><\/span><\/span><\/strong><\/span><\/span><span style=\"font-size: 18px;\"><strong><span style=\"font-family: Calibri;\"><span style=\"font-family: Arial;\"><span style=\"font-style: normal;\"><a href=\"https:\/\/www.daelimtransformer.com\/pl\/onan-transformers.html\" target=\"_blank\" rel=\"noopener\"><span style=\"color: #c0392b;\">Ostateczny przewodnik po transformatorach ONAN<\/span><\/a><\/span><\/span><\/span><\/strong><\/span><\/p>\n<h2 style=\"margin-top: 18.0000pt; margin-bottom: 6.0000pt; text-align: left;\"><span class=\"ez-toc-section\" id=\"What_Are_The_Various_Accessories_Of_CSA_2274\"><\/span>Jakie s\u0105 r\u00f3\u017cne akcesoria CSA 227.4?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Transformatory mog\u0105 by\u0107 dostarczane z r\u00f3\u017cnymi opcjonalnymi akcesoriami, je\u015bli nabywca sobie \u017cyczy:<\/p>\n<ul>\n<li>odporne na korozj\u0119 do stosowania w mocno zanieczyszczonych regionach;<\/li>\n<li>odporne na korozj\u0119 w silnie zanieczyszczonych \u015brodowiskach;<\/li>\n<li>nieck\u0105 drena\u017cow\u0105 i korkiem nape\u0142niaj\u0105cym; oraz<\/li>\n<li>wy\u0142\u0105cznikami obci\u0105\u017ceniowymi.<\/li>\n<li>Numer nadrukowany na przedniej cz\u0119\u015bci os\u0142ony to kod magazynowy klienta.<\/li>\n<li>Klemy do mocowania szcz\u0119k do studni przelotowych<\/li>\n<li>\u00a0otw\u00f3r o \u015brednicy 25 mm zakryty wyjmowan\u0105 p\u0142ytk\u0105 ze stali nierdzewnej umieszczon\u0105 na dnie cylindra;<\/li>\n<li>U\u017cyj jako wska\u017anika awarii zdalnej;<\/li>\n<li>\u00a0dwie podstawowe klamry skonfigurowane inaczej z przy\u0142\u0105czami wysokiego napi\u0119cia;<\/li>\n<li>Zabezpieczenia blokuj\u0105ce dla wy\u0142\u0105cznik\u00f3w obci\u0105\u017ceniowych;<\/li>\n<li>przelotki niskonapi\u0119ciowe typu \u015brubowego lub widelcowego;<\/li>\n<li>wk\u0142adki wy\u0142\u0105cznikowe obci\u0105\u017ceniowe z do\u0142\u0105czon\u0105 os\u0142on\u0105 przeciwpy\u0142ow\u0105;<\/li>\n<li>dwie podstawowe klamry s\u0105 zorganizowane inaczej<\/li>\n<li>po\u0142\u0105czenia wysokiego napi\u0119cia;<\/li>\n<li>test impulsowy: Test ten jest uwa\u017cany za test rutynowy, mo\u017ce by\u0107 za\u017c\u0105dany przez nabywc\u0119 i musi by\u0107 przeprowadzony.<\/li>\n<li>Na podstawie normy ANSI\/IEEE C57.12.90<\/li>\n<li>Sta\u0142a lub tymczasowa etykieta kodu kreskowego zgodnie z ANSI\/IEEE C57.12.35;<\/li>\n<li>minimalna impedancja w celu ograniczenia pr\u0105du zwarcia w urz\u0105dzeniu serwisowym:<\/li>\n<\/ul>\n<p style=\"margin-top: 18pt; margin-bottom: 6pt; text-align: left;\"><span style=\"color: #27ae60;\"><strong><span style=\"font-size: 18px;\">Dowiedz si\u0119 wi\u0119cej: <\/span><\/strong><\/span><strong><span style=\"font-size: 18px;\"><a href=\"https:\/\/www.daelimtransformer.com\/pl\/transformer-impedance.html\" target=\"_blank\" rel=\"noopener\"><span style=\"color: #c0392b;\">Wp\u0142yw impedancji na projektowanie transformator\u00f3w<\/span><\/a><\/span><\/strong><\/p>\n<h2><span class=\"ez-toc-section\" id=\"CSA_2274_Quality_Of_Work_And_Finish\"><\/span><a id=\"7\" name=\"7\"><\/a>Jako\u015b\u0107 pracy i wyko\u0144czenia CSA 227.4<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p align=\"justify\">ANSI C57.12.28 to norma, kt\u00f3r\u0105 musi spe\u0142nia\u0107 zewn\u0119trzne wyko\u0144czenie. Kolor musi by\u0107 albo zielony sprz\u0119towy, o warto\u015bci Munsella 9GY1.5\/2.6, albo zielony morski, o warto\u015bci Munsella 4.82 G 4.07\/3.35. Dostawa b\u0119dzie w odcieniu zielonym morskim, je\u015bli nie wybrano koloru. Norma CSA W59 musi by\u0107 przestrzegana we wszystkich spawaniach. Wytw\u00f3rca musi spe\u0142nia\u0107 wszystkie kwalifikacje i uzyska\u0107 zatwierdzenie od Kanadyjskiego Biura Spawalniczego, aby dostosowa\u0107 si\u0119 do CSA W47.1.<\/p>\n<p align=\"justify\">O ile nie zaznaczone inaczej, tolerancje wymiarowe b\u0119d\u0105 nast\u0119puj\u0105ce:<\/p>\n<ul>\n<li>dla wszystkich wymiar\u00f3w poni\u017cej 300 mm, 5 mm;<\/li>\n<li>\u00a0dla wszystkich wymiar\u00f3w 300 mm i wy\u017cszych, 10 mm; oraz<\/li>\n<li>\u00a0wszystkie otwory mia\u0142y nominalne wymiary.<\/li>\n<\/ul>\n<h2><span class=\"ez-toc-section\" id=\"Pad_Mounted_Transformer_Markings_And_Exterior_Information\"><\/span><a id=\"8\" name=\"8\"><\/a>Oznaczenia i informacje zewn\u0119trzne transformatora montowanego na p\u0142ycie<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Je\u015bli wykorzystuje si\u0119 naklejki, musz\u0105 one spe\u0142nia\u0107 kryteria etykiety typu A zgodnie z CSA C22.2 Nr 0.15 i zachowa\u0107 swoj\u0105 integralno\u015b\u0107 w temperaturze \u201340 \u00b0C. W odniesieniu do naklejek, musisz spe\u0142nia\u0107 standardy etykiety typu A CSA C22.2 z Nr 0.15 i zachowa\u0107 ich integralno\u015b\u0107 w temperaturach tak niskich jak \u201340 \u00b0C.<\/p>\n<p align=\"justify\">Ponadto, transformatory musz\u0105 by\u0107 wyposa\u017cone w po\u0142\u0105czenie tabliczki znamionowej i schematu okablowania. Tabliczka znamionowa musi zawiera\u0107 wszystkie informacje wymagane w punkcie 10.2.3 i musi pozostawa\u0107 widoczna przez ca\u0142y okres u\u017cytkowania transformator\u00f3w w normalnych warunkach pracy.<\/p>\n<p align=\"justify\">To\u017csamo\u015b\u0107 po\u0142\u0105cze\u0144 terminalowych musi by\u0107 podana na samym zbiorniku oraz na tabliczce znamionowej, kt\u00f3ra \u0142\u0105czy swoje funkcje jako schemat po\u0142\u0105cze\u0144 i schemat po\u0142\u0105cze\u0144 terminalowych.<\/p>\n<p class=\"p\" style=\"margin-top: 0.0000pt; margin-bottom: 0.0000pt; text-align: justify; margin: 5pt 0pt;\" align=\"justify\"><span style=\"color: #27ae60;\"><span style=\"font-size: 18px;\"><strong><span style=\"font-family: Calibri;\"><span style=\"font-family: Arial;\"><span style=\"font-style: normal;\">Przeczytaj wi\u0119cej: <\/span><\/span><\/span><\/strong><\/span><\/span><span style=\"font-size: 18px;\"><strong><span style=\"font-family: Calibri;\"><span style=\"font-family: Arial;\"><span style=\"font-style: normal;\"><a href=\"https:\/\/www.daelimtransformer.com\/pl\/transformer-connection.html\" target=\"_blank\" rel=\"noopener\"><span style=\"color: #c0392b;\">Ostateczny przewodnik po najcz\u0119\u015bciej zadawanych pytaniach dotycz\u0105cych po\u0142\u0105cze\u0144 transformator\u00f3w<\/span><\/a><\/span><\/span><\/span><\/strong><\/span><\/p>\n<h3 align=\"justify\"><span class=\"ez-toc-section\" id=\"Details_About_The_Interior_Of_The_Transformer_Compartment\"><\/span><a id=\"8.1\" name=\"8.1\"><\/a>Szczeg\u00f3\u0142y dotycz\u0105ce wn\u0119trza przedzia\u0142u transformatora<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p align=\"justify\">Nast\u0119puj\u0105ce informacje znajduj\u0105 si\u0119 w komorze transformatora. Te formacje powinny by\u0107 namalowane na powierzchni komory zbiornika za pomoc\u0105 15 do 25 mm:<\/p>\n<ul>\n<li>Wysokie oznaczenia terminali napi\u0119cia<\/li>\n<li>Niskie oznaczenia terminali napi\u0119cia<\/li>\n<li>prze\u0142\u0105cznik podw\u00f3jnego napi\u0119cia (je\u015bli jest obecny); oraz TC (prze\u0142\u0105cznik zmiany odczep\u00f3w), je\u015bli jest obecny.<\/li>\n<li>wskazania napi\u0119cia lokalizacji prze\u0142\u0105cznika selektora napi\u0119cia;<\/li>\n<li>numeryczna pozycja odczepu prze\u0142\u0105cznika zmiany odczep\u00f3w (je\u015bli dostarczona jest tablica z oznaczeniem). Cyfry musz\u0105 mie\u0107 co najmniej 8 mm wysoko\u015bci. Wy\u0142\u0105czniki roz\u0142\u0105czaj\u0105ce<\/li>\n<\/ul>\n<p align=\"justify\">Etykiety ostrzegawcze spe\u0142niaj\u0105ce kryteria musz\u0105 by\u0107 umieszczone w obszarze s\u0105siaduj\u0105cym z uchwytami transformator\u00f3w, kt\u00f3re maj\u0105 wy\u0142\u0105czniki obwodowe, kt\u00f3re mog\u0105 by\u0107 obs\u0142ugiwane zewn\u0119trznie. Przed uruchomieniem prze\u0142\u0105cznika etykieta musi wskazywa\u0107 niezb\u0119dne \u015brodki ostro\u017cno\u015bci, kt\u00f3re musz\u0105 by\u0107 wykonane. Ponadto, opr\u00f3cz zagro\u017ce\u0144 elektrycznych, etykiety ostrzegawcze musz\u0105 by\u0107 zainstalowane odpowiednio, a powinny by\u0107 identyczne oznaczenia, kt\u00f3re nabywca z\u0142o\u017cy producentowi do monta\u017cu.<\/p>\n<p class=\"p\" style=\"margin-top: 0.0000pt; margin-bottom: 0.0000pt; text-align: justify; margin: 5pt 0pt;\" align=\"justify\"><span style=\"color: #27ae60;\"><span style=\"font-size: 18px;\"><strong>Wypr\u00f3buj za darmo: <\/strong><\/span><\/span><span style=\"font-size: 18px;\"><strong><a href=\"https:\/\/daelimbelefic.com\/the-ultimate-guide-to-renewable-power-plants\/\" target=\"_blank\" rel=\"noopener\"><span style=\"color: #c0392b;\">Ostateczny przewodnik po odnawialnych elektrowniach<\/span><\/a><\/strong><\/span><\/p>\n<p style=\"text-align: left; margin: 0pt 0pt 0.0001pt;\"><span style=\"font-size: 18pt;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"font-weight: bold;\"><b><span style=\"font-size: 16.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #000000;\"><span style=\"font-weight: bold;\"><span style=\"font-style: normal;\"><a id=\"9\" name=\"9\"><\/a>Producent transformator\u00f3w CSA C227.4 do instalacji tr\u00f3jfazowych<\/span><\/span><\/span><\/span><\/span><\/b><\/span><\/span><\/span><\/p>\n<p><iframe title=\"odtwarzacz wideo YouTube\" src=\"https:\/\/www.youtube.com\/embed\/Of1IBanQEVs\" width=\"100%\" height=\"315\" frameborder=\"0\" allowfullscreen=\"allowfullscreen\"><\/iframe><\/p>\n<p align=\"justify\">Daelim od wielu lat rozwija rynek kanadyjski i posiada certyfikat cUL transformatora. Zesp\u00f3\u0142 DAELIM zna r\u00f3\u017cne wymagania techniczne i eksperymentalne standard\u00f3w CSA dotycz\u0105cych transformator\u00f3w. Ka\u017cdego roku do Kanady eksportowane s\u0105 tysi\u0105ce transformator\u00f3w. Ponadto Daelim ma zespo\u0142y monta\u017cowe i posprzeda\u017cowe w Kanadzie, aby szybko rozwi\u0105za\u0107 wszelkie problemy, kt\u00f3re napotka\u0142e\u015b na miejscu.<\/p>\n<p class=\"p\" style=\"margin-top: 0.0000pt; margin-bottom: 0.0000pt; text-align: justify; margin: 5pt 0pt;\" align=\"justify\"><span style=\"font-size: 12pt;\"><span style=\"text-justify: inter-ideograph;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"font-style: normal;\">Bez wzgl\u0119du na to, czy jeste\u015b dystrybutorem transformator\u00f3w, instytucj\u0105 u\u017cyteczno\u015bci publicznej, czy ko\u0144cowym u\u017cytkownikiem, mo\u017cesz <strong><a href=\"https:\/\/www.daelimtransformer.com\/pl\/contact.html\" target=\"_blank\" rel=\"noopener\">kontakt z Daelim.<\/a><\/strong> przez skrzynk\u0119 pocztow\u0105 <span style=\"color: #27ae60;\"><strong>service@daelim-<\/strong><\/span><\/span><\/span><\/span><span style=\"color: #27ae60;\"><strong><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"font-style: normal;\"><span style=\"font-family: Arial;\">elektryczny<\/span><\/span><\/span><\/span><\/strong><\/span><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"font-style: normal;\"><span style=\"color: #27ae60;\"><strong>.com<\/strong><\/span> i telefonicznie: <strong><span style=\"color: #27ae60;\">+86-15801656761.<\/span><\/strong><\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<h2 style=\"margin-top: 18.0000pt; margin-bottom: 6.0000pt; text-align: left;\"><span class=\"ez-toc-section\" id=\"In_Conclusion\"><\/span><span style=\"font-size: 18pt;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"font-weight: bold;\"><b><span style=\"font-size: 16.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"color: #000000;\"><span style=\"font-weight: bold;\"><span style=\"font-style: normal;\"><a id=\"10\" name=\"10\"><\/a>Podsumowuj\u0105c<\/span><\/span><\/span><\/span><\/span><\/b><\/span><\/span><\/span><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p class=\"p\" style=\"margin-top: 0.0000pt; margin-bottom: 0.0000pt; text-align: justify; margin: 5pt 0pt;\" align=\"justify\"><span style=\"font-size: 12pt;\"><span style=\"text-justify: inter-ideograph;\"><span style=\"font-family: Calibri;\"><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"font-style: normal;\">Powy\u017csza tre\u015b\u0107 g\u0142\u00f3wnie dotyczy standardu projektowania CSA C227.4: 21. W odniesieniu do specyfikacji i wymaga\u0144 projektowych dotycz\u0105cych 3 P<\/span><\/span><\/span><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"font-style: normal;\"><span style=\"font-family: Arial;\">hase<\/span><\/span><\/span><\/span><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"font-style: normal;\">\u00a0P<\/span><\/span><\/span><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"font-style: normal;\"><span style=\"font-family: Arial;\">ad<\/span><\/span><\/span><\/span><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"font-style: normal;\">\u00a0M<\/span><\/span><\/span><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: \u5b8b\u4f53;\"><span style=\"font-style: normal;\"><span style=\"font-family: Arial;\">mounted distribution<\/span><\/span><\/span><\/span><span style=\"font-size: 11.0000pt;\"><span style=\"font-family: Arial;\"><span style=\"font-style: normal;\">\u00a0Charakterystyki elektryczne transformator\u00f3w w celu zapewnienia standardu i bezpiecze\u0144stwa transformatora. Aby osi\u0105gn\u0105\u0107 bezpiecze\u0144stwo i oszcz\u0119dno\u015b\u0107 energii transformator\u00f3w w zastosowaniach.<\/span><\/span><\/span><\/span><\/span><\/span><\/p>\n<p><!-- \u5de6\u53f3\u56fe\u6587--><\/p>\n<p><!-- \u8c46\u8150\u5757\u56fe\u6587\u4e0a\u4e0b--><\/p>\n<p><!--\u6587\u5b57\u6a21\u5757--><\/p>\n<p><!-- \u5de6\u53f3\u56fe\u6587--><\/p>\n<p><!--\u6587\u5b57\u6a21\u5757--><\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Transformers are vital in our daily lives since they convert alternating current to direct current and transport electricity to your devices, equipment, and others to ensure their durability and efficient performance. Therefore, as a transformer buyer and manufacturer, you should be familiar with the local transformer design requirements and standards. This article tells the Canadian [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":7351,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[279],"tags":[],"class_list":["post-7350","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articles-news"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.daelimtransformer.com\/pl\/wp-json\/wp\/v2\/posts\/7350","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.daelimtransformer.com\/pl\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.daelimtransformer.com\/pl\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.daelimtransformer.com\/pl\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.daelimtransformer.com\/pl\/wp-json\/wp\/v2\/comments?post=7350"}],"version-history":[{"count":0,"href":"https:\/\/www.daelimtransformer.com\/pl\/wp-json\/wp\/v2\/posts\/7350\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.daelimtransformer.com\/pl\/wp-json\/wp\/v2\/media\/7351"}],"wp:attachment":[{"href":"https:\/\/www.daelimtransformer.com\/pl\/wp-json\/wp\/v2\/media?parent=7350"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.daelimtransformer.com\/pl\/wp-json\/wp\/v2\/categories?post=7350"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.daelimtransformer.com\/pl\/wp-json\/wp\/v2\/tags?post=7350"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}