{"id":7614,"date":"2026-01-05T09:28:25","date_gmt":"2026-01-05T09:28:25","guid":{"rendered":"https:\/\/daelimtransformer.com\/?p=7614"},"modified":"2026-01-22T07:41:59","modified_gmt":"2026-01-22T07:41:59","slug":"prevention-and-treatment-measures-for-transformer-core-grounding-faults","status":"publish","type":"post","link":"https:\/\/www.daelimtransformer.com\/pl\/prevention-and-treatment-measures-for-transformer-core-grounding-faults.html","title":{"rendered":"\u015arodki zapobiegawcze i leczenia usterki uziemienia rdzenia transformatora"},"content":{"rendered":"<div id=\"contentMain\" class=\"article-content\"><!-- \u5de6\u53f3\u56fe\u6587--><!--\u6587\u5b57\u6a21\u5757--><\/p>\n<p><!-- \u8c46\u8150\u5757\u56fe\u6587\u4e0a\u4e0b--><\/p>\n<p><!-- \u5de6\u53f3\u56fe\u6587--><\/p>\n<p><!--\u6587\u5b57\u6a21\u5757--><\/p>\n<p><!-- \u8c46\u8150\u5757\u56fe\u6587\u4e0a\u4e0b--><\/p>\n<p><!-- \u5de6\u53f3\u56fe\u6587--><\/p>\n<p><!--\u6587\u5b57\u6a21\u5757--><\/p>\n<p><!-- \u8c46\u8150\u5757\u56fe\u6587\u4e0a\u4e0b--><\/p>\n<p><!-- \u5de6\u53f3\u56fe\u6587--><\/p>\n<p><!--\u6587\u5b57\u6a21\u5757--><\/p>\n<p><!-- \u8c46\u8150\u5757\u56fe\u6587\u4e0a\u4e0b--><\/p>\n<p><!-- \u5de6\u53f3\u56fe\u6587--><\/p>\n<p><!--\u6587\u5b57\u6a21\u5757--><\/p>\n<p><!-- \u8c46\u8150\u5757\u56fe\u6587\u4e0a\u4e0b--><\/p>\n<div class=\"row\">\n<div class=\"col-lg-12 article-content\">\n<h2><span class=\"ez-toc-section\" id=\"During_Transformer_Installation_and_Maintenance\"><\/span><strong><span style=\"font-size: 20px;\">Podczas instalacji i konserwacji transformatora<\/span><\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<ul>\n<li><span style=\"font-size: 18px;\">Zmierzy\u0107 op\u00f3r izolacji rdzenia i zacisk\u00f3w.<\/span><\/li>\n<li><span style=\"font-size: 18px;\">Izolowa\u0107 i owin\u0105\u0107 wszelkie elementy lub przewody uziemiaj\u0105ce rdzenia, kt\u00f3re nie s\u0105 izolowane.<\/span><\/li>\n<li><span style=\"font-size: 18px;\">Poprowad\u017a przew\u00f3d uziemiaj\u0105cy do dost\u0119pnej lokalizacji do pomiaru podczas pracy, i regularnie sprawdzaj pr\u0105d uziemienia rdzenia, kt\u00f3ry powinien og\u00f3lnie wynosi\u0107 oko\u0142o 0,5 A lub mniej.<\/span><\/li>\n<\/ul>\n<h2><span class=\"ez-toc-section\" id=\"Strengthen_Transformer_Operation_Supervision\"><\/span><span style=\"font-size: 20px;\"><strong>Wzmocnienie nadzoru nad prac\u0105 transformatora<\/strong><\/span><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<ul>\n<li><span style=\"font-size: 18px;\">Regularnie mierz pr\u0105d uziemienia rdzenia podczas inspekcji operacyjnych.<\/span><\/li>\n<li><span style=\"font-size: 18px;\">\u015aci\u015ble przestrzega\u0107 cyklu analizy chromatografii oleju transformatorowego. Uwaga: Podczas u\u017cywania metody trzech stosunk\u00f3w do diagnozowania wad uziemienia rdzenia, upewnij si\u0119, \u017ce zawarto\u015b\u0107 gazu w oleju jest wystarczaj\u0105co wysoka (og\u00f3lnie przekraczaj\u0105ca warto\u015b\u0107 uwagi), aby unikn\u0105\u0107 b\u0142\u0119dnej oceny i niepotrzebnych strat ekonomicznych.<\/span><\/li>\n<\/ul>\n<h2><span class=\"ez-toc-section\" id=\"Temporary_Measures_for_Core_Grounding_Faults\"><\/span><strong><span style=\"font-size: 20px;\">Tymczasowe \u015brodki w przypadku wad uziemienia rdzenia<\/span><\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<ul>\n<li><span style=\"font-size: 18px;\">Je\u015bli nie mo\u017cna od razu wy\u0142\u0105czy\u0107, po\u0142\u0105cz opornik szeregowo z p\u0119tl\u0105 uziemiaj\u0105c\u0105 dla du\u017cych pr\u0105d\u00f3w uziemienia. Rozwa\u017c dodanie odgromnik\u00f3w niskonapi\u0119ciowych 220V-380V po obu stronach opornika, aby zapobiec jego otwarciu. Ogranicz pr\u0105d uziemienia do 100 mA i otw\u00f3rz normalny punkt uziemienia rdzenia. To redukuje pr\u0105d przez blachy stalowe krzemowe i ogrzewanie rdzenia, zapobiegaj\u0105c eskalacji wad. Wzmocnij analiz\u0119 chromatograficzn\u0105 i pomiar pr\u0105du uziemienia w tym okresie.<\/span><\/li>\n<\/ul>\n<h2><span class=\"ez-toc-section\" id=\"Handling_Multi-point_Grounding_Faults\"><\/span><span style=\"font-size: 20px;\"><strong>Zarz\u0105dzanie wadami uziemienia w wielu punktach<\/strong><\/span><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<ul>\n<li><span style=\"font-size: 18px;\">Unikaj po\u015bpiesznego zakrywania pokrywy w celu znalezienia i naprawienia zb\u0119dnych punkt\u00f3w uziemienia. Je\u015bli op\u00f3r izolacji jest niski, u\u017cyj impulsowego wy\u0142adowania AC lub DC przez normalny punkt uziemienia, aby przepali\u0107 zb\u0119dne punkty uziemienia. Oszcz\u0119dza to zasoby i unika d\u0142ugoterminowych przerw w zasilaniu. Je\u015bli op\u00f3r izolacji nie jest niski, odprowad\u017a niewielk\u0105 ilo\u015b\u0107 oleju, otw\u00f3rz r\u0119kaw uziemiaj\u0105cy i sprawd\u017a oraz napraw przew\u00f3d uziemiaj\u0105cy. Wspieraj dane analizy chromatograficznej przed i po leczeniu.<\/span><\/li>\n<\/ul>\n<h2><span class=\"ez-toc-section\" id=\"Inspection_After_Cover_Lifting\"><\/span><strong><span style=\"font-size: 20px;\">Inspekcja po podniesieniu pokrywy<\/span><\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<ul>\n<li><span style=\"font-size: 18px;\">Sprawd\u017a wygl\u0105d rdzenia pod k\u0105tem wad. Je\u015bli nie znaleziono, stosuj nast\u0119puj\u0105ce metody:<\/span>\n<ul>\n<li><span style=\"font-size: 18px;\">Zmierz op\u00f3r izolacji \u015brub przechodz\u0105cych przez rdze\u0144 i izoluj\u0105cych element\u00f3w mocuj\u0105cych, aby sprawdzi\u0107, czy zaciski stykaj\u0105 si\u0119 z rdzeniem.<\/span><\/li>\n<li><span style=\"font-size: 18px;\">Pod\u0142\u0105cz multimetr mi\u0119dzy rdzeniem a ziemi\u0105, aby znale\u017a\u0107 wad\u0119 poprzez zmiany oporu. Przesu\u0144 po mo\u017cliwych punktach uziemienia za pomoc\u0105 izoluj\u0105cej tektury, aby obserwowa\u0107 zmiany wskaz\u00f3wki multimetru i okre\u015bli\u0107 lokalizacj\u0119.<\/span><\/li>\n<li><span style=\"font-size: 18px;\">Zastosuj napi\u0119cie AC lub DC, obserwuj d\u017awi\u0119ki wy\u0142adowania lub dym topniej\u0105cy i podejmij dzia\u0142ania w celu wzmocnienia izolacji. W razie potrzeby podnie\u015b obiekt lub zwr\u00f3\u0107 go do fabryki w celu naprawy.<\/span><\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<h2><span class=\"ez-toc-section\" id=\"Design_and_Manufacturing_Considerations\"><\/span><span style=\"font-size: 20px;\"><strong>Rozwa\u017cania projektowe i produkcyjne<\/strong><\/span><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<ul>\n<li><span style=\"font-size: 18px;\">Dok\u0142adnie rozwa\u017c margines izolacji rdzenia w stosunku do ziemi i zacisk\u00f3w oraz racjonalnie zorganizuj przestrze\u0144. Izoluj cz\u0119\u015bci lub komponenty metalowe, kt\u00f3re mog\u0105 wp\u0142ywa\u0107 na izolacj\u0119.<\/span><\/li>\n<\/ul>\n<p><span style=\"font-size: 18px;\">Bior\u0105c pod uwag\u0119 cechy konstrukcyjne rdzenia transformatora, wady uziemienia w wielu punktach mog\u0105 wynika\u0107 z r\u00f3\u017cnych czynnik\u00f3w i form, wp\u0142ywaj\u0105c na bezpieczn\u0105 prac\u0119. Nale\u017cy podj\u0105\u0107 \u015brodki zapobiegawcze w zakresie projektowania, produkcji, instalacji, eksploatacji i konserwacji. Wzmocnij nadz\u00f3r nad testami chromatograficznymi i elektrycznymi, wykonaj wczesn\u0105 diagnoz\u0119 oraz przeprowad\u017a kompleksow\u0105 analiz\u0119 i ocen\u0119. Dostosuj konkretne metody przetwarzania do r\u00f3\u017cnych sytuacji, aby zminimalizowa\u0107 straty zwi\u0105zane z wadami, oszcz\u0119dzaj\u0105c czas i pieni\u0105dze.<\/span><\/p>\n<\/div>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>During Transformer Installation and Maintenance Measure the insulation resistance of the core and clamps. Insulate and wrap any core grounding connection pieces or wires that are not insulated. Lead the grounding wire to an accessible location for measurement during operation, and regularly check the core grounding current, which should generally be around 0.5A or less. [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[279],"tags":[],"class_list":["post-7614","post","type-post","status-publish","format-standard","hentry","category-articles-news"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.daelimtransformer.com\/pl\/wp-json\/wp\/v2\/posts\/7614","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.daelimtransformer.com\/pl\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.daelimtransformer.com\/pl\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.daelimtransformer.com\/pl\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.daelimtransformer.com\/pl\/wp-json\/wp\/v2\/comments?post=7614"}],"version-history":[{"count":0,"href":"https:\/\/www.daelimtransformer.com\/pl\/wp-json\/wp\/v2\/posts\/7614\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.daelimtransformer.com\/pl\/wp-json\/wp\/v2\/media?parent=7614"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.daelimtransformer.com\/pl\/wp-json\/wp\/v2\/categories?post=7614"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.daelimtransformer.com\/pl\/wp-json\/wp\/v2\/tags?post=7614"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}