{"id":7622,"date":"2026-01-05T09:29:39","date_gmt":"2026-01-05T09:29:39","guid":{"rendered":"https:\/\/daelimtransformer.com\/?p=7622"},"modified":"2026-10-25T00:41:11","modified_gmt":"2026-10-24T16:41:11","slug":"comprehensive-analysis-of-large-transformer-faults-by-gas-chromatography","status":"publish","type":"post","link":"https:\/\/www.daelimtransformer.com\/pl\/comprehensive-analysis-of-large-transformer-faults-by-gas-chromatography.html","title":{"rendered":"Kompleksowa analiza du\u017cych usterek transformator\u00f3w za pomoc\u0105 chromatografii gazowej"},"content":{"rendered":"<figure class=\"wp-block-image size-full\"><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone wp-image-13777 size-full\" src=\"https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/01\/Comprehensive-Analysis-of-Large-Transformer-Faults-by-Gas-Chromatography.jpg\" alt=\"Kompleksowa analiza du\u017cych usterek transformator\u00f3w za pomoc\u0105 chromatografii gazowej\" width=\"1376\" height=\"768\" srcset=\"https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/01\/Comprehensive-Analysis-of-Large-Transformer-Faults-by-Gas-Chromatography.jpg 1376w, https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/01\/Comprehensive-Analysis-of-Large-Transformer-Faults-by-Gas-Chromatography-768x429.jpg 768w, https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/01\/Comprehensive-Analysis-of-Large-Transformer-Faults-by-Gas-Chromatography-18x10.jpg 18w, https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/01\/Comprehensive-Analysis-of-Large-Transformer-Faults-by-Gas-Chromatography-600x335.jpg 600w\" sizes=\"(max-width: 1376px) 100vw, 1376px\" \/><\/figure>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\">Du\u017ce transformatory elektryczne stanowi\u0105 jeden z najcenniejszych i najbardziej kluczowych element\u00f3w ka\u017cdego systemu dystrybucji energii elektrycznej. System jest od nich tak bardzo zale\u017cny, \u017ce ka\u017cda awaria lub usterka tych du\u017cych transformator\u00f3w mocy mo\u017ce powa\u017cnie wp\u0142yn\u0105\u0107 na stabilno\u015b\u0107 i wydajno\u015b\u0107 systemu.<\/p>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\">W niniejszym artykule przedstawimy bardzo szczeg\u00f3\u0142ow\u0105 analiz\u0119 wykrywania uszkodze\u0144 w du\u017cych transformatorach mocy za pomoc\u0105 chromatografii gazowej. Wyja\u015bnimy, jakie gazy powstaj\u0105 w du\u017cych transformatorach elektrycznych w wyniku r\u00f3\u017cnych rodzaj\u00f3w uszkodze\u0144 oraz w jaki spos\u00f3b chromatografia gazowa pomaga wykrywa\u0107 te gazy w celu zlokalizowania uszkodze\u0144.<\/p>\r\n\r\n\r\n\r\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-block-buttons-is-layout-flex wp-container-core-buttons-is-layout-3e41869c\">\r\n<div class=\"wp-block-button quoteModal\"><a class=\"wp-block-button__link wp-element-button\">Uzyskaj Cen\u0119<\/a><\/div>\r\n<\/div>\r\n\r\n\r\n\r\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"What_Is_Gas_Chromatography\"><\/span>Czym jest chromatografia gazowa?<span class=\"ez-toc-section-end\"><\/span><\/h2>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\">Chromatografia gazowa to laboratoryjna technika analityczna stosowana do rozdzielania i identyfikacji poszczeg\u00f3lnych gaz\u00f3w rozpuszczonych w dowolnym rodzaju oleju izolacyjnego, zw\u0142aszcza w <a href=\"https:\/\/www.daelimtransformer.com\/pl\/the-complete-guide-to-transformer-oil-dissolved-gas-analysis.html\">olej izolacyjny do transformator\u00f3w<\/a>. Proces ten pozwala r\u00f3wnie\u017c w bardzo prosty spos\u00f3b okre\u015bli\u0107 st\u0119\u017cenie poszczeg\u00f3lnych gaz\u00f3w wykrytych w oleju izolacyjnym transformatora.<\/p>\r\n\r\n\r\n\r\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Why_Electrical_Transformers_Need_Gas_Chromatography_Analysis\"><\/span>Dlaczego transformatory elektryczne wymagaj\u0105 analizy metod\u0105 chromatografii gazowej<span class=\"ez-toc-section-end\"><\/span><\/h2>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\">Olej transformatorowy dostarcza wielu informacji na temat stanu technicznego transformatora oraz usterek wyst\u0119puj\u0105cych wewn\u0105trz zbiornika transformatora. Analiza oleju transformatorowego metod\u0105 chromatografii gazowej pozwala nam oceni\u0107 stan techniczny transformatora i zrozumie\u0107 charakter wyst\u0119puj\u0105cych w nim usterek.<\/p>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\">Transformatory elektryczne s\u0105 projektowane i konstruowane w taki spos\u00f3b, \u017ce do izolacji poszczeg\u00f3lnych cz\u0119\u015bci transformatora stosuje si\u0119 r\u00f3\u017cne materia\u0142y izolacyjne. Ka\u017cdy transformator elektryczny mo\u017ce zawiera\u0107 mineralny olej izolacyjny, izolacj\u0119 z papieru celulozowego oraz <a href=\"https:\/\/www.daelimtransformer.com\/pl\/transformer-insulation.html\">materia\u0142 izolacyjny z p\u0142yty prasowanej<\/a> do izolacji uzwojenia transformatora i zespo\u0142u rdzenia.<\/p>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\">Materia\u0142y te mog\u0105 bardzo \u0142atwo ulega\u0107 rozk\u0142adowi pod wp\u0142ywem obci\u0105\u017ce\u0144 elektrycznych lub termicznych wyst\u0119puj\u0105cych w warunkach szczytowego obci\u0105\u017cenia zbiornika transformatora elektrycznego. Zale\u017cy to od rodzaju usterki oraz temperatury, w kt\u00f3rej ta usterka wyst\u0119puje.<\/p>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\">Chromatografia gazowa przeprowadzona na oleju transformatorowym pozwoli na wyodr\u0119bnienie tych gaz\u00f3w z danej pr\u00f3bki oleju transformatorowego. Proces ten pozwoli na pomiar konkretnego st\u0119\u017cenia dowolnego lub wszystkich gaz\u00f3w wykrytych w danej pr\u00f3bce i zapewni wyniki o wysokiej dok\u0142adno\u015bci. Wyniki s\u0105 zazwyczaj przedstawiane w cz\u0119\u015bciach na milion (ppm) lub w mikrolitrach na litr (\u00b5L\/L). St\u0119\u017cenie to stanowi podstaw\u0119 analizy gaz\u00f3w rozpuszczonych (DGA).<\/p>\r\n\r\n\r\n\r\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Why_Gas_Chromatography_Is_Important_for_Large_Transformers\"><\/span>Dlaczego chromatografia gazowa ma znaczenie w przypadku du\u017cych transformator\u00f3w<span class=\"ez-toc-section-end\"><\/span><\/h2>\r\n<p>\r\n\r\n<\/p>\r\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/www.daelimtransformer.com\/pl\/power-transformer.html\"><img decoding=\"async\" class=\"alignnone size-full wp-image-13781\" src=\"https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/01\/Why-Gas-Chromatography-Is-Important-for-Large-Transformers.webp\" alt=\"Dlaczego chromatografia gazowa ma znaczenie w przypadku du\u017cych transformator\u00f3w\" width=\"1200\" height=\"764\" srcset=\"https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/01\/Why-Gas-Chromatography-Is-Important-for-Large-Transformers.webp 1200w, https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/01\/Why-Gas-Chromatography-Is-Important-for-Large-Transformers-768x489.webp 768w, https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/01\/Why-Gas-Chromatography-Is-Important-for-Large-Transformers-18x12.webp 18w, https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/01\/Why-Gas-Chromatography-Is-Important-for-Large-Transformers-600x382.webp 600w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/a><\/p>\r\n<p>Chromatografia gazowa pomaga nam zapobiega\u0107 przedwczesnym i nag\u0142ym awariom du\u017cych transformator\u00f3w elektrycznych, wskazuj\u0105c stan techniczny transformatora oraz usterki wyst\u0119puj\u0105ce wewn\u0105trz jego obudowy.<\/p>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\">Du\u017ce transformatory mocy, wykorzystywane w sieciach energetycznych o zasi\u0119gu krajowym oraz w instalacjach dystrybucyjnych, kosztuj\u0105 zazwyczaj setki tysi\u0119cy dolar\u00f3w. Produkcja tych transformator\u00f3w trwa kilka tygodni, a ich transport i monta\u017c \u2013 kilka miesi\u0119cy.<\/p>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\">Wymiana jednego transformatora mocy nie tylko b\u0119dzie Ci\u0119 kosztowa\u0107 sporo pieni\u0119dzy, ale tak\u017ce zajmie kilka miesi\u0119cy pracy \u2013 i to tylko na sam\u0105 wymian\u0119 transformatora. Jest to jeden z g\u0142\u00f3wnych powod\u00f3w, dla kt\u00f3rych tego typu badania przeprowadza si\u0119 na transformatorze przed jego transportem w celu monta\u017cu, a tak\u017ce przez ca\u0142y okres eksploatacji.<\/p>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\">Chromatografia gazowa ma szereg zalet, kt\u00f3re wymieniono poni\u017cej:<\/p>\r\n\r\n\r\n\r\n<ul class=\"wp-block-list\">\r\n<li>Chromatografia gazowa umo\u017cliwia wczesne wykrycie pogorszenia stanu izolacji wewn\u0105trz transformatora elektrycznego.<\/li>\r\n\r\n\r\n\r\n<li>Analiza i wykrywanie usterek elektrycznych, zanim przerodz\u0105 si\u0119 one w katastrofalne awarie.<\/li>\r\n\r\n\r\n\r\n<li>Testy pomagaj\u0105 nam ograniczy\u0107 <a href=\"https:\/\/www.daelimtransformer.com\/pl\/transformer-maintenance.html\">koszt utrzymania<\/a> transformatora poprzez wczesne wykrywanie niewielkich usterek wyst\u0119puj\u0105cych wewn\u0105trz zbiornika transformatora.<\/li>\r\n\r\n\r\n\r\n<li>Testy pomagaj\u0105 przed\u0142u\u017cy\u0107 <a href=\"https:\/\/www.daelimtransformer.com\/pl\/transformer-lifespan.html\">\u017cywotno\u015b\u0107 transformatora<\/a> poprzez zapobieganie przedwczesnym awariom.<\/li>\r\n\r\n\r\n\r\n<li>Badania metod\u0105 chromatografii gazowej pomagaj\u0105 nam r\u00f3wnie\u017c zapobiega\u0107 nieplanowanym przerwom w pracy transformatora poprzez wczesne wykrywanie drobnych usterek, kt\u00f3re mog\u0105 prowadzi\u0107 do niezamierzonych przestoj\u00f3w transformatora.<\/li>\r\n\r\n\r\n\r\n<li>Test ten pozwala nam r\u00f3wnie\u017c zapewni\u0107 wi\u0119ksz\u0105 niezawodno\u015b\u0107 dzia\u0142ania dzi\u0119ki wprowadzeniu dodatkowych etap\u00f3w w ramach planowej konserwacji, kt\u00f3re umo\u017cliwiaj\u0105 wykrywanie drobnych usterek.<\/li>\r\n<\/ul>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\">Analiz\u0119 gaz\u00f3w rozpuszczonych w du\u017cych transformatorach mocy przeprowadza si\u0119 zazwyczaj co 3 miesi\u0105ce, co 6 miesi\u0119cy lub raz w roku; wszystko zale\u017cy od wieku badanego transformatora elektrycznego oraz charakteru jego zastosowania.<\/p>\r\n\r\n\r\n\r\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" class=\"wp-image-13748\" src=\"https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/10\/dga-photo-substation-1.webp\" alt=\"Du\u017ce transformatory mocy zainstalowane w stacji elektroenergetycznej na wolnym powietrzu, monitorowane za pomoc\u0105 analizy gaz\u00f3w rozpuszczonych\" width=\"1200\" height=\"675\" srcset=\"https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/10\/dga-photo-substation-1.webp 817w, https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/10\/dga-photo-substation-1-768x431.webp 768w, https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/10\/dga-photo-substation-1-18x10.webp 18w, https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/10\/dga-photo-substation-1-600x337.webp 600w\" sizes=\"(max-width: 1200px) 100vw, 1200px\" \/><\/figure>\r\n\r\n\r\n\r\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Dissolved_Gas_Analysis_Operating_Procedure\"><\/span>Procedura operacyjna dotycz\u0105ca analizy gaz\u00f3w rozpuszczonych<span class=\"ez-toc-section-end\"><\/span><\/h2>\r\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-13779\" src=\"https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/01\/Dissolved-Gas-Analysis-Operating-Procedure.webp\" alt=\"Procedura operacyjna dotycz\u0105ca analizy gaz\u00f3w rozpuszczonych\" width=\"1408\" height=\"651\" srcset=\"https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/01\/Dissolved-Gas-Analysis-Operating-Procedure.webp 1408w, https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/01\/Dissolved-Gas-Analysis-Operating-Procedure-768x355.webp 768w, https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/01\/Dissolved-Gas-Analysis-Operating-Procedure-18x8.webp 18w, https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/01\/Dissolved-Gas-Analysis-Operating-Procedure-600x277.webp 600w\" sizes=\"(max-width: 1408px) 100vw, 1408px\" \/><\/p>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\">W transformatorach elektrycznych olej transformatorowy pe\u0142ni funkcj\u0119 zar\u00f3wno materia\u0142u izolacyjnego, jak i ch\u0142odziwa. Gdy w transformatorze elektrycznym wyst\u0105pi stan nieprawid\u0142owy spowodowany usterk\u0105 po\u0142\u0105cze\u0144 elektrycznych, energia powoduje zerwanie wi\u0105za\u0144 chemicznych w oleju oraz w sta\u0142ej izolacji transformatora. W wyniku rozk\u0142adu izolacji powstaj\u0105 gazy, takie jak<\/p>\r\n\r\n\r\n\r\n<ul class=\"wp-block-list\">\r\n<li>Wod\u00f3r<\/li>\r\n\r\n\r\n\r\n<li>Metan<\/li>\r\n\r\n\r\n\r\n<li>Etan<\/li>\r\n\r\n\r\n\r\n<li>Etylen<\/li>\r\n\r\n\r\n\r\n<li>Acetylen<\/li>\r\n\r\n\r\n\r\n<li>Tlenek w\u0119gla<\/li>\r\n\r\n\r\n\r\n<li>Dwutlenek w\u0119gla<\/li>\r\n<\/ul>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\">W celu zbadania tych gaz\u00f3w wykonuje si\u0119 nast\u0119puj\u0105ce czynno\u015bci:<\/p>\r\n\r\n\r\n\r\n<ul class=\"wp-block-list\">\r\n<li>Pobranie pr\u00f3bki oleju z transformatora<\/li>\r\n\r\n\r\n\r\n<li>Przeprowadzenie analizy chromatografii gazowej pr\u00f3bki oleju<\/li>\r\n\r\n\r\n\r\n<li>Opracowano pe\u0142ny raport, w kt\u00f3rym przedstawiono poszczeg\u00f3lne gazy rozpuszczone oraz ich st\u0119\u017cenie w ppm<\/li>\r\n\r\n\r\n\r\n<li>Zesp\u00f3\u0142 in\u017cynier\u00f3w analizuje rozk\u0142ad gazu w celu zidentyfikowania potencjalnych usterek<\/li>\r\n<\/ul>\r\n\r\n\r\n\r\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Fault_Gases_Detected_by_Gas_Chromatography\"><\/span>Gazy uszkodzeniowe wykrywane za pomoc\u0105 chromatografii gazowej<span class=\"ez-toc-section-end\"><\/span><\/h2>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\">Podczas przeprowadzania analizy chromatografii gazowej oleju transformatorowego zazwyczaj wykrywa si\u0119 nast\u0119puj\u0105ce gazy, z kt\u00f3rych ka\u017cdy wskazuje na konkretn\u0105 usterk\u0119.<\/p>\r\n\r\n\r\n\r\n<figure class=\"wp-block-table\">\r\n<table>\r\n<thead>\r\n<tr>\r\n<th>Gaz<\/th>\r\n<th>Wz\u00f3r chemiczny<\/th>\r\n<th>Oznacza<\/th>\r\n<\/tr>\r\n<\/thead>\r\n<tbody>\r\n<tr>\r\n<td>Wod\u00f3r<\/td>\r\n<td>H\u2082<\/td>\r\n<td>Wy\u0142adowania cz\u0119\u015bciowe, wy\u0142adowania koronowe<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>Metan<\/td>\r\n<td>CH\u2084<\/td>\r\n<td>Przegrzanie w niskiej temperaturze<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>Etan<\/td>\r\n<td>C\u2082H\u2086<\/td>\r\n<td>Przegrzewanie oleju<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>Etylen<\/td>\r\n<td>C\u2082H\u2084<\/td>\r\n<td>Przegrzanie w wysokiej temperaturze<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>Acetylen<\/td>\r\n<td>C\u2082H\u2082<\/td>\r\n<td>Wy\u0142adowania \u0142ukowe i powa\u017cne usterki elektryczne<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>Tlenek w\u0119gla<\/td>\r\n<td>CO<\/td>\r\n<td>Degradacja izolacji papierowej<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>Dwutlenek w\u0119gla<\/td>\r\n<td>CO\u2082<\/td>\r\n<td>Starzenie celulozy<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>Tlen<\/td>\r\n<td>O\u2082<\/td>\r\n<td>Ocena wyciek\u00f3w powietrza<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>Azot<\/td>\r\n<td>N\u2082<\/td>\r\n<td>Wnikanie powietrza<\/td>\r\n<\/tr>\r\n<\/tbody>\r\n<\/table>\r\n<\/figure>\r\n\r\n\r\n\r\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Relationship_Between_Fault_Temperature_and_Gas_Generation\"><\/span>Zale\u017cno\u015b\u0107 mi\u0119dzy temperatur\u0105 uskoku a wytwarzaniem gazu<span class=\"ez-toc-section-end\"><\/span><\/h2>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\">Usterki transformatora zazwyczaj powoduj\u0105 powstawanie dodatkowego ciep\u0142a odpadowego wewn\u0105trz zbiornika. W zale\u017cno\u015bci od temperatury materia\u0142 izolacyjny i inne czynniki mog\u0105 powodowa\u0107 wydzielanie si\u0119 r\u00f3\u017cnych gaz\u00f3w.<\/p>\r\n\r\n\r\n\r\n<figure class=\"wp-block-table\">\r\n<table>\r\n<thead>\r\n<tr>\r\n<th>Temperatura uszkodzenia<\/th>\r\n<th>G\u0142\u00f3wne rodzaje wydobywanego gazu<\/th>\r\n<\/tr>\r\n<\/thead>\r\n<tbody>\r\n<tr>\r\n<td>&lt;150 \u00b0C<\/td>\r\n<td>Metan<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>150\u2013300 \u00b0C<\/td>\r\n<td>Metan + etan<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>300\u2013700 \u00b0C<\/td>\r\n<td>Etylen<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>&gt;700 \u00b0C<\/td>\r\n<td>Acetylen<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>Przegrzanie celulozy<\/td>\r\n<td>CO + CO\u2082<\/td>\r\n<\/tr>\r\n<\/tbody>\r\n<\/table>\r\n<\/figure>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\">Istnieje prosta zale\u017cno\u015b\u0107 mi\u0119dzy wzrostem temperatury a rozmiarem uszkodze\u0144: im wy\u017csza temperatura w miejscu uszkodzenia, tym powa\u017cniejsze b\u0119d\u0105 wewn\u0119trzne uszkodzenia transformatora.<\/p>\r\n\r\n\r\n\r\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-13731 size-full\" src=\"https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/10\/dga-diagram-temperature.webp\" alt=\"Tabela przedstawiaj\u0105ca zakresy temperatur uskok\u00f3w oraz gazy rozpuszczone wytwarzane przez ka\u017cdy z nich\" width=\"1400\" height=\"820\" srcset=\"https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/10\/dga-diagram-temperature.webp 1400w, https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/10\/dga-diagram-temperature-768x450.webp 768w, https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/10\/dga-diagram-temperature-18x12.webp 18w, https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/10\/dga-diagram-temperature-600x351.webp 600w\" sizes=\"(max-width: 1400px) 100vw, 1400px\" \/><\/figure>\r\n\r\n\r\n\r\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Types_of_Transformer_Faults_Identified_By_Gas_Chromatography\"><\/span>Rodzaje uszkodze\u0144 transformator\u00f3w wykrywane za pomoc\u0105 chromatografii gazowej<span class=\"ez-toc-section-end\"><\/span><\/h2>\r\n\r\n\r\n\r\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Partial_Discharge\"><\/span>Cz\u0119\u015bciowe wy\u0142adowanie<span class=\"ez-toc-section-end\"><\/span><\/h3>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/www.daelimtransformer.com\/pl\/what-is-iec-60270\/\">Wy\u0142adowanie cz\u0119\u015bciowe<\/a> W transformatorze elektrycznym jest to miejscowy wy\u0142adowanie elektryczne, kt\u00f3re nie powoduje ca\u0142kowitego przerwania izolacji. Tego rodzaju usterka wynika z d\u0142ugotrwa\u0142ego uszkodzenia izolacji o niskiej energii oraz z pogorszenia jej stanu spowodowanego wilgoci\u0105.<\/p>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\">Cztery najcz\u0119stsze przyczyny wy\u0142adowa\u0144 cz\u0119\u015bciowych to obecno\u015b\u0107 wilgoci w oleju transformatorowym, puste przestrzenie w materiale izolacyjnym, starzenie si\u0119 materia\u0142u izolacyjnego oraz, czasami, wady produkcyjne.<\/p>\r\n\r\n\r\n\r\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Corona_Discharge\"><\/span>Wy\u0142adowanie koronowe<span class=\"ez-toc-section-end\"><\/span><\/h3>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\">Wynika to g\u0142\u00f3wnie z wysokiej g\u0119sto\u015bci pola elektrycznego wok\u00f3\u0142 przewod\u00f3w transformatora elektrycznego. W wyniku tego wy\u0142adowania w oleju transformatorowym powstaje g\u0142\u00f3wnie wod\u00f3r oraz niewielka ilo\u015b\u0107 metanu. Usterka ta jest zazwyczaj mniej szkodliwa ni\u017c inne usterki, takie jak wy\u0142adowania \u0142ukowe, ale je\u015bli zostanie zignorowana, mo\u017ce przerodzi\u0107 si\u0119 w powa\u017cniejsze awarie.<\/p>\r\n\r\n\r\n\r\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Low_Temperature_Thermal_Fault\"><\/span>Usterka termiczna przy niskiej temperaturze<span class=\"ez-toc-section-end\"><\/span><\/h3>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\">Je\u015bli temperatura elektryczna spadnie poni\u017cej 300 stopni Celsjusza, uznaje si\u0119 to za tzw. niskotemperaturowe uszkodzenie termiczne w transformatorze elektrycznym. Powoduje to powstawanie metanu i etanu w oleju transformatorowym. Mo\u017cliwymi przyczynami tej usterki termicznej niskotemperaturowej s\u0105 lu\u017ane po\u0142\u0105czenia elektryczne, niewystarczaj\u0105ce ch\u0142odzenie, powstawanie lokalnych punkt\u00f3w przegrzania w transformatorze elektrycznym oraz przeci\u0105\u017cenie transformatora przez pod\u0142\u0105czone obci\u0105\u017cenie.<\/p>\r\n\r\n\r\n\r\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Medium_Temperature_Thermal_Fault\"><\/span>Usterka termiczna w zakresie \u015brednich temperatur<span class=\"ez-toc-section-end\"><\/span><\/h3>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\">Je\u015bli temperatura transformatora elektrycznego utrzymuje si\u0119 w zakresie od 300 stopni do 700 stopni Celsjusza, uznaje si\u0119 to za usterk\u0119 termiczn\u0105 \u015bredniej temperatury. Usterka ta mo\u017ce powodowa\u0107 wydzielanie trzech r\u00f3\u017cnych gaz\u00f3w, a mianowicie etylenu, metanu i etanu. Tego typu usterka wynika zazwyczaj ze z\u0142ego styku mi\u0119dzy cz\u0119\u015bciami przewodz\u0105cymi transformatora, wysokiej rezystancji mi\u0119dzy po\u0142\u0105czeniami elektrycznymi transformatora oraz przegrzania rdzenia transformatora.<\/p>\r\n\r\n\r\n\r\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"High_Temperature_Thermal_Fault\"><\/span>Usterka termiczna spowodowana wysok\u0105 temperatur\u0105<span class=\"ez-toc-section-end\"><\/span><\/h3>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\">Je\u015bli temperatura transformatora elektrycznego przekroczy 700 stopni Celsjusza, mowa jest o usterce termicznej spowodowanej wysok\u0105 temperatur\u0105. Usterka ta powoduje przede wszystkim wysokie st\u0119\u017cenie etylenu oraz znaczn\u0105 ilo\u015b\u0107 acetylenu w oleju transformatorowym. Tego typu usterka wynika g\u0142\u00f3wnie z powa\u017cnego przegrzania transformatora elektrycznego, wad lub uszkodze\u0144 wyst\u0119puj\u0105cych w rdzeniu transformatora, spowodowanych nagrzewaniem si\u0119 g\u0142\u00f3wnych element\u00f3w przewodz\u0105cych transformatora.<\/p>\r\n\r\n\r\n\r\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Arcing\"><\/span>\u0141uk elektryczny<span class=\"ez-toc-section-end\"><\/span><\/h3>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\">Tworzenie si\u0119 \u0142uku elektrycznego jest jedn\u0105 z najcz\u0119stszych, a jednocze\u015bnie najniebezpieczniejszych usterek wyst\u0119puj\u0105cych w transformatorze elektrycznym. Tworzenie si\u0119 \u0142uku elektrycznego w transformatorze mo\u017ce powodowa\u0107 wytwarzanie znacznych ilo\u015bci acetylenu oraz niewielkich ilo\u015bci wodoru i etylenu. Przyczynami powstawania \u0142uku elektrycznego w transformatorze elektrycznym s\u0105: uszkodzenie izolacji uzwojenia transformatora, problemy z prze\u0142\u0105cznikiem odga\u0142\u0119zie\u0144, wewn\u0119trzne przeskoki iskrowe oraz poluzowane przewody transformatora elektrycznego.<\/p>\r\n\r\n\r\n\r\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Cellulose_Insulation_Degradation\"><\/span>Degradacja izolacji celulozowej<span class=\"ez-toc-section-end\"><\/span><\/h3>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\">W transformatorze elektrycznym wyst\u0119puj\u0105 r\u00f3\u017cne rodzaje materia\u0142\u00f3w izolacyjnych, a izolacja papierowa ulega rozk\u0142adowi w inny spos\u00f3b ni\u017c olej mineralny. W wyniku rozk\u0142adu izolacji papierowej w oleju transformatorowym powstaj\u0105 tlenek w\u0119gla i dwutlenek w\u0119gla. Wysokie st\u0119\u017cenie tlenku w\u0119gla zazwyczaj wskazuje na post\u0119puj\u0105ce pogorszenie stanu izolacji wewn\u0105trz transformatora.<\/p>\r\n\r\n\r\n\r\n\r\n\r\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Factors_Affecting_DGA_Accuracy\"><\/span>Czynniki wp\u0142ywaj\u0105ce na dok\u0142adno\u015b\u0107 analizy DGA<span class=\"ez-toc-section-end\"><\/span><\/h2>\r\n\r\n\r\n\r\n<ul class=\"wp-block-list\">\r\n<li>Nieprawid\u0142owe pobranie pr\u00f3bki oleju, z kt\u00f3rej ma zosta\u0107 przeprowadzona analiza gaz\u00f3w rozpuszczonych, mo\u017ce spowodowa\u0107 b\u0142\u0119dy w wynikach. W wi\u0119kszo\u015bci przypadk\u00f3w to w\u0142a\u015bnie zanieczyszczenie atmosferyczne, kt\u00f3re dostaje si\u0119 do pr\u00f3bki oleju podczas pobierania, prowadzi do b\u0142\u0119dnych wynik\u00f3w.<\/li>\r\n\r\n\r\n\r\n<li>Utleniony olej transformatorowy mo\u017ce wp\u0142ywa\u0107 na procesy powstawania gaz\u00f3w, a tym samym zmienia\u0107 wyniki analizy gaz\u00f3w rozpuszczonych.<\/li>\r\n\r\n\r\n\r\n<li>Du\u017ce obci\u0105\u017cenie transformatora mo\u017ce spowodowa\u0107 zwi\u0119kszenie wytwarzania gazu w oleju transformatorowym, co w pierwszej kolejno\u015bci znajduje odzwierciedlenie w wynikach analizy gazowej (DGA).<\/li>\r\n\r\n\r\n\r\n<li>Je\u015bli transformator elektryczny b\u0119dzie nadal pracowa\u0142 w wysokiej temperaturze roboczej, mo\u017ce to przyspieszy\u0107 rozk\u0142ad oleju transformatorowego i materia\u0142u izolacyjnego, co w pierwszej kolejno\u015bci wp\u0142ynie na wyniki analizy gaz\u00f3w rozpuszczonych.<\/li>\r\n\r\n\r\n\r\n<li>Aby w pe\u0142ni wykorzysta\u0107 wyniki analizy gaz\u00f3w rozpuszczonych, badanie nale\u017cy przeprowadza\u0107 w regularnych odst\u0119pach czasu; zbyt d\u0142ugie lub zbyt kr\u00f3tkie odst\u0119py mog\u0105 wp\u0142yn\u0105\u0107 na wiarygodno\u015b\u0107 wynik\u00f3w.<\/li>\r\n<\/ul>\r\n\r\n\r\n\r\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Advantages_of_Gas_Chromatography\"><\/span>Zalety chromatografii gazowej<span class=\"ez-toc-section-end\"><\/span><\/h2>\r\n\r\n\r\n\r\n<ul class=\"wp-block-list\">\r\n<li>Chromatografia gazowa jest badaniem ca\u0142kowicie nieniszcz\u0105cym, co oznacza, \u017ce stan produktu pozostaje niezmieniony zar\u00f3wno przed, jak i po badaniu.<\/li>\r\n\r\n\r\n\r\n<li>Chromatografia gazowa zapewnia bardzo wysok\u0105 dok\u0142adno\u015b\u0107 pomiaru ko\u0144cowej zawarto\u015bci gaz\u00f3w w oleju transformatorowym<\/li>\r\n\r\n\r\n\r\n<li>Chromatografia gazowa umo\u017cliwia bardzo wczesne wykrywanie usterek w transformatorach elektrycznych, co pozwala unikn\u0105\u0107 d\u0142ugich przestoj\u00f3w<\/li>\r\n\r\n\r\n\r\n<li>Chromatografia gazowa pozwala wykrywa\u0107 r\u00f3\u017cne rodzaje usterek w ramach tego samego procesu<\/li>\r\n\r\n\r\n\r\n<li>Proces ten przyczynia si\u0119 do ograniczenia konieczno\u015bci przeprowadzania konserwacji predykcyjnej oraz do zmniejszenia liczby nieoczekiwanych awarii transformator\u00f3w.<\/li>\r\n\r\n\r\n\r\n<li>Chromatografia gazowa przyczynia si\u0119 do wyd\u0142u\u017cenia okresu eksploatacji transformator\u00f3w elektrycznych oraz do zminimalizowania koszt\u00f3w konserwacji.<\/li>\r\n\r\n\r\n\r\n<li>Wszystkie powy\u017csze kwestie sprowadzaj\u0105 si\u0119 do jednego wniosku: chromatografia gazowa przyczynia si\u0119 do zwi\u0119kszenia niezawodno\u015bci systemu.<\/li>\r\n<\/ul>\r\n\r\n\r\n\r\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Limitations_of_Gas_Chromatography\"><\/span>Ograniczenia chromatografii gazowej<span class=\"ez-toc-section-end\"><\/span><\/h2>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\">Chocia\u017c chromatografia gazowa jest skuteczn\u0105 metod\u0105 wykrywania usterek wyst\u0119puj\u0105cych w transformatorze, ma ona swoje ograniczenia.<\/p>\r\n\r\n\r\n\r\n<ul class=\"wp-block-list\">\r\n<li>Proces ten wymaga specjalistycznego sprz\u0119tu oraz laboratorium, aby mo\u017cna by\u0142o wykona\u0107 te prace.<\/li>\r\n\r\n\r\n\r\n<li>Po zako\u0144czeniu procesu potrzebna jest osoba do\u015bwiadczona i posiadaj\u0105ca wysokie kwalifikacje, kt\u00f3ra zinterpretuje wyniki analizy i podejmie ostateczn\u0105 decyzj\u0119.<\/li>\r\n\r\n\r\n\r\n<li>Wzory gazowe mog\u0105 si\u0119 nak\u0142ada\u0107, gdy jednocze\u015bnie wyst\u0119puje wiele uskok\u00f3w.<\/li>\r\n\r\n\r\n\r\n<li>B\u0142\u0119dy pr\u00f3by mog\u0105 z \u0142atwo\u015bci\u0105 wp\u0142yn\u0105\u0107 na wynik.<\/li>\r\n<\/ul>\r\n\r\n\r\n\r\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"FAQ\"><\/span><span id=\"FAQ\" class=\"ez-toc-section\"><\/span><strong>FAQ<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\r\n\r\n\r\n\r\n<div class=\"saswp-faq-block-section\">\r\n<ol style=\"list-style-type: none;\">\r\n<li style=\"list-style-type: none;\">\r\n<h5 class=\"saswp-faq-question-title\"><span class=\"ez-toc-section\" id=\"What_Is_the_IEC_Standard_For_DGA_Analysis\"><\/span><span id=\"What_Is_the_IEC_Standard_For_DGA_Analysis\" class=\"ez-toc-section\"><\/span><strong>Jaka jest norma IEC dotycz\u0105ca analizy gaz\u00f3w rozpuszczonych w oleju (DGA)?<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h5>\r\n<p class=\"saswp-faq-answer-text\">Mi\u0119dzynarodowa norma elektrotechniczna IEC 60599 zawiera niezb\u0119dne informacje dotycz\u0105ce interpretacji wynik\u00f3w analizy DGA oraz standardowych warto\u015bci progowych.<\/p>\r\n<\/li>\r\n<li style=\"list-style-type: none;\">\r\n<h5 class=\"saswp-faq-question-title\"><span class=\"ez-toc-section\" id=\"What_Is_IEEE_Standard_For_Electrical_Transformer_DGA\"><\/span><span id=\"What_Is_IEEE_Standard_For_Electrical_Transformer_DGA\" class=\"ez-toc-section\"><\/span><strong>Czym jest norma IEEE dotycz\u0105ca analizy gazowej (DGA) w transformatorach elektrycznych?<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h5>\r\n<p class=\"saswp-faq-answer-text\">Norma IEEE C57.104 jest norm\u0105 obowi\u0105zkow\u0105, zawieraj\u0105c\u0105 informacje dotycz\u0105ce interpretacji wynik\u00f3w analizy gaz\u00f3w ulatniaj\u0105cych (DGA) w transformatorach elektrycznych.<\/p>\r\n<\/li>\r\n<li style=\"list-style-type: none;\">\r\n<h5 class=\"saswp-faq-question-title\"><span class=\"ez-toc-section\" id=\"How_Do_I_Interpret_DGA_Analysis_Results\"><\/span><span id=\"How_Do_I_Interpret_DGA_Analysis_Results\" class=\"ez-toc-section\"><\/span><strong>Jak zinterpretowa\u0107 wyniki analizy DGA?<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h5>\r\n<p class=\"saswp-faq-answer-text\">Zrozumienie wynik\u00f3w analizy gaz\u00f3w rozpuszczonych w dowolnym transformatorze wymaga du\u017cego do\u015bwiadczenia. Aby zinterpretowa\u0107 wyniki, nale\u017cy uwzgl\u0119dni\u0107 zalecenia producenta dotycz\u0105ce przeprowadzania bada\u0144 oraz normy mi\u0119dzynarodowe.<\/p>\r\n<\/li>\r\n<\/ol>\r\n<\/div>\r\n\r\n\r\n\r\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-block-buttons-is-layout-flex wp-container-core-buttons-is-layout-3e41869c\">\r\n<div class=\"wp-block-button quoteModal\"><a class=\"wp-block-button__link wp-element-button\">Popro\u015b o wycen\u0119 ju\u017c teraz<\/a><\/div>\r\n<\/div>\r\n\r\n\r\n\r\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Conclusion\"><\/span>Wnioski<span class=\"ez-toc-section-end\"><\/span><\/h2>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\">Chromatografi\u0119 gazow\u0105 przeprowadza si\u0119 w celu analizy gaz\u00f3w rozpuszczonych w du\u017cych transformatorach. Proces ten polega na pobraniu pr\u00f3bki oleju transformatorowego z transformatora i poddaniu jej analizie w celu uzyskania pe\u0142nych informacji na temat r\u00f3\u017cnych gaz\u00f3w w nim rozpuszczonych oraz dok\u0142adnej ilo\u015bci ka\u017cdego z nich. Firma Daelim przeprowadza t\u0119 analiz\u0119 dla ka\u017cdego transformatora, aby zapewni\u0107 zgodno\u015b\u0107 z mi\u0119dzynarodowymi normami, takimi jak IEEE, ANSI, CSA, IEC i inne. Je\u015bli maj\u0105 Pa\u0144stwo jakiekolwiek pytania dotycz\u0105ce du\u017cych transformator\u00f3w, <a href=\"https:\/\/www.daelimtransformer.com\/pl\/contact-us\/\">Skontaktuj si\u0119 z nami<\/a>.<\/p>\r\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-12960\" src=\"https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/06\/daelim-transformer-heavy-duty-transformer-factory.webp\" alt=\"daelim transformer ci\u0119\u017cki transformator fabryka\" width=\"1398\" height=\"600\" srcset=\"https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/06\/daelim-transformer-heavy-duty-transformer-factory.webp 1398w, https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/06\/daelim-transformer-heavy-duty-transformer-factory-768x330.webp 768w, https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/06\/daelim-transformer-heavy-duty-transformer-factory-18x8.webp 18w, https:\/\/www.daelimtransformer.com\/wp-content\/uploads\/2026\/06\/daelim-transformer-heavy-duty-transformer-factory-600x258.webp 600w\" sizes=\"(max-width: 1398px) 100vw, 1398px\" \/><\/p>\r\n\r\n<p>&nbsp;<\/p>","protected":false},"excerpt":{"rendered":"<p>The large electrical transformers are one of the most valuable and critical assets in any electricity distribution system. The system relies on them so much that any fault or problem in these large power transformers can seriously affect the stability and efficiency of the system. This article will provide a very comprehensive analysis of large [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":13777,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[279],"tags":[],"class_list":["post-7622","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articles-news"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.daelimtransformer.com\/pl\/wp-json\/wp\/v2\/posts\/7622","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.daelimtransformer.com\/pl\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.daelimtransformer.com\/pl\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.daelimtransformer.com\/pl\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.daelimtransformer.com\/pl\/wp-json\/wp\/v2\/comments?post=7622"}],"version-history":[{"count":6,"href":"https:\/\/www.daelimtransformer.com\/pl\/wp-json\/wp\/v2\/posts\/7622\/revisions"}],"predecessor-version":[{"id":13782,"href":"https:\/\/www.daelimtransformer.com\/pl\/wp-json\/wp\/v2\/posts\/7622\/revisions\/13782"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.daelimtransformer.com\/pl\/wp-json\/wp\/v2\/media\/13777"}],"wp:attachment":[{"href":"https:\/\/www.daelimtransformer.com\/pl\/wp-json\/wp\/v2\/media?parent=7622"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.daelimtransformer.com\/pl\/wp-json\/wp\/v2\/categories?post=7622"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.daelimtransformer.com\/pl\/wp-json\/wp\/v2\/tags?post=7622"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}