{"id":7997,"date":"2026-01-05T11:29:37","date_gmt":"2026-01-05T11:29:37","guid":{"rendered":"https:\/\/daelimtransformer.com\/?p=7997"},"modified":"2026-03-19T08:56:39","modified_gmt":"2026-03-19T08:56:39","slug":"transformers-at-the-heart-of-nvidias-800-v-hvdc-power-architecture","status":"publish","type":"post","link":"https:\/\/www.daelimtransformer.com\/pl\/transformers-at-the-heart-of-800v-hvdc.html","title":{"rendered":"Transformatory w sercu architektury zasilania HVDC 800 V firmy NVIDIA"},"content":{"rendered":"<div id=\"contentMain\" class=\"article-content\">\n<p><!-- \u5de6\u53f3\u56fe\u6587--><\/p>\n<div class=\"row\">\n<div class=\"signleContent col-lg-6 mb-3\">\n<p><img decoding=\"async\" class=\"img-fluid\" src=\"\/media\/115\/Transformers-at-the-Heart-of-NVIDIA-800-V-HVDC.webp\" alt=\"Transformatory w sercu 800 V HVDC\" \/><\/p>\n<\/div>\n<div class=\"signleContent col-lg-6 mb-3\">\n<div class=\"line-height-22 mt-3 fs-16 text-dark\">\n<p>W miar\u0119 jak \u015bwiat przyjmuje sztuczn\u0105 inteligencj\u0119 w codziennych zadaniach, obci\u0105\u017cenie AI ro\u015bnie w dramatycznym tempie. Centra danych zasilaj\u0105ce AI staj\u0105 w obliczu gwa\u0142townie rosn\u0105cego zapotrzebowania na moc, kt\u00f3re przeskakuje z obecnych setek kW do kilku MW w bardzo kr\u00f3tkim czasie.<\/p>\n<p>Zachodzi konieczno\u015b\u0107 zmiany sposobu zasilania tych centr\u00f3w danych AI i ilo\u015bci energii, jak\u0105 konsumuj\u0105, aby rozwi\u0105za\u0107 nawet najprostsze zadania. Nowa architektura 800 V DC (HVDC) firmy NVIDIA to najbardziej widoczny sygna\u0142 tej zmiany w bran\u017cy.<\/p>\n<p>Podczas gdy wi\u0119kszo\u015b\u0107 dyskusji dotyczy p\u00f3\u0142przewodnik\u00f3w o du\u017cej szeroko\u015bci pasma, wysoko g\u0119stych szyn zasilaj\u0105cych i konwerter\u00f3w GaN\/Sic, transformatory elektryczne pozostaj\u0105 kluczowym elementem systemu zasilaj\u0105cego te centra danych AI. Transformator jest kluczow\u0105 cz\u0119\u015bci\u0105 systemu dystrybucji energii elektrycznej, zw\u0142aszcza w pierwszych dw\u00f3ch etapach \u0142a\u0144cucha zasilania sieci do szafy.<\/p>\n<p><a class=\"btn btn-primary mt-1 font-weight-bold fs-16 pageBtn quoteModal\">Skontaktuj si\u0119 z Daelim Transformer<\/a><\/p>\n<\/div>\n<\/div>\n<\/div>\n<p><!--\u6587\u5b57\u6a21\u5757--><\/p>\n<p><!-- \u8c46\u8150\u5757\u56fe\u6587\u4e0a\u4e0b--><\/p>\n<p><!-- \u5de6\u53f3\u56fe\u6587--><\/p>\n<p><!--\u6587\u5b57\u6a21\u5757--><\/p>\n<p><!-- \u8c46\u8150\u5757\u56fe\u6587\u4e0a\u4e0b--><\/p>\n<p><!-- \u5de6\u53f3\u56fe\u6587--><\/p>\n<p><!--\u6587\u5b57\u6a21\u5757--><\/p>\n<p><!-- \u8c46\u8150\u5757\u56fe\u6587\u4e0a\u4e0b--><\/p>\n<p><!-- \u5de6\u53f3\u56fe\u6587--><\/p>\n<p><!--\u6587\u5b57\u6a21\u5757--><\/p>\n<p><!-- \u8c46\u8150\u5757\u56fe\u6587\u4e0a\u4e0b--><\/p>\n<p><!-- \u5de6\u53f3\u56fe\u6587--><\/p>\n<p><!--\u6587\u5b57\u6a21\u5757--><\/p>\n<p><!-- \u8c46\u8150\u5757\u56fe\u6587\u4e0a\u4e0b--><\/p>\n<div class=\"row\">\n<div class=\"col-lg-12 article-content\">\n<p>W tym artykule om\u00f3wimy, w jaki spos\u00f3b tradycyjny transformator pozostaje niezast\u0105piony w operacjach centr\u00f3w danych, jak firma Daelim Transformer oferuje nowoczesne us\u0142ugi zwi\u0105zane z transformatorami elektrycznymi zaprojektowanymi specjalnie dla zasilania centr\u00f3w danych oraz w jaki spos\u00f3b transformatory p\u00f3\u0142przewodnikowe zast\u0105pi\u0105 te tradycyjne transformatory w operacjach centr\u00f3w danych.<\/p>\n<p><a id=\"mdnTags0\" class=\"mdnTags\" name=\"mdn0\" data-index=\"0\"><\/a><\/p>\n<h2><span class=\"ez-toc-section\" id=\"Grid_to_Data_Centre\"><\/span>Sie\u0107 do centrum danych<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Zgodnie z opisan\u0105 architektur\u0105 firmy NVIDIA, system \u0142\u0105czy si\u0119 z transformatorem na dw\u00f3ch g\u0142\u00f3wnych etapach. Pocz\u0105tkowo w centrum obiektu, gdzie nadchodz\u0105ca moc AC jest konwertowana na pr\u0105d sta\u0142y, a nast\u0119pnie w modu\u0142ach mocy szafy do pracy z obni\u017caniem napi\u0119cia.<\/p>\n<p><a id=\"mdnTags1\" name=\"mdn1\" data-index=\"1\"><\/a><\/p>\n<h3><span class=\"ez-toc-section\" id=\"Facility_Level_AC_to_DC_Conversion\"><\/span>Konwersja AC na DC na poziomie obiektu<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>W konwersji AC na DC w obiekcie g\u0142\u00f3wnym celem jest konwersja nadchodz\u0105cego \u015bredniego napi\u0119cia pr\u0105du zmiennego z krajowej dostawy sieciowej lub lokalnego systemu zasilania na stabilny pr\u0105d sta\u0142y o napi\u0119ciu 800 volt\u00f3w. W tym procesie rol\u0105 transformatora jest zapewnienie niezb\u0119dnej konwersji napi\u0119cia oraz kluczowej izolacji galwanicznej mi\u0119dzy sieci\u0105 u\u017cyteczno\u015bci a wewn\u0119trznym systemem dystrybucji mocy 800 VDC centrum danych.<\/p>\n<p><a id=\"mdnTags2\" name=\"mdn2\" data-index=\"2\"><\/a><\/p>\n<h3><span class=\"ez-toc-section\" id=\"In_Rack_DC_to_DC_Conversion\"><\/span>Konwersja DC na DC w szafie serwerowej<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Gdy ju\u017c znajduje si\u0119 w szafie serwerowej, napi\u0119cie 800 VDC jest nadal zbyt wysokie dla indywidualnych komponent\u00f3w i musi zosta\u0107 dalej obni\u017cone do ni\u017cszego napi\u0119cia, kt\u00f3re mo\u017cna bezpiecznie u\u017cywa\u0107 przez <a href=\"https:\/\/www.ibm.com\/think\/topics\/gpu\" rel=\"noopener\">GPU<\/a> i inne komponenty serwera. Aby zrealizowa\u0107 to zadanie, w szafach s\u0105 zintegrowane wysoko kompaktowe, wysoce wydajne konwertery DC na DC, aby przeprowadzi\u0107 ten proces obni\u017cania napi\u0119cia. Konwertery wykorzystuj\u0105 ma\u0142e, wysokocz\u0119stotliwo\u015bciowe transformatory zintegrowane lub p\u0142askie.<\/p>\n<p class=\"p\" style=\"margin-top: 13px; text-align: left;\"><img decoding=\"async\" style=\"width: 1000px; height: 336px;\" title=\"Schemat-architektury-systemu-zasilania-ata-Center-800V-HVDC\" src=\"\/media\/115\/Data-Center-800V-HVDC-Power-Supply-System-Architecture-Diagram.webp\" alt=\"Schemat-architektury-systemu-zasilania-ata-Center-800V-HVDC\" \/><\/p>\n<p class=\"p\" style=\"padding: 0pt 0pt 0pt 0pt; text-align: center;\" align=\"center\"><span style=\"font-size: 12pt;\"><span style=\"background: #ffffff;\"><span style=\"font-family: Calibri;\"><a href=\"https:\/\/developer.nvidia.com\/blog\/nvidia-800-v-hvdc-architecture-will-power-the-next-generation-of-ai-factories\/\" rel=\"noopener\"><i><u><span class=\"15\" style=\"font-size: 11.5000pt;\"><span style=\"background: #ffffff;\"><span style=\"font-family: sans-serif;\"><span style=\"color: #1155cc;\"><span style=\"text-decoration: underline;\"><span style=\"text-underline: single;\"><span style=\"font-style: italic;\">Architektura NVIDIA 800 VDC <\/span><\/span><\/span><\/span><\/span><\/span><\/span><\/u><\/i><\/a><i><span style=\"font-size: 11.5000pt;\"><span style=\"background: #ffffff;\"><span style=\"font-family: sans-serif;\"><span style=\"color: #1a1a1a;\"><span style=\"font-style: italic;\">minimalizuje konwersje energii\u00a0<\/span><\/span><\/span><\/span><\/span><\/i><\/span><\/span><\/span>(\u0179r\u00f3d\u0142o obrazu: NVIDIA)<\/p>\n<p>Te dwa transformatory zaanga\u017cowane w dostarczanie energii do centrum danych zapewniaj\u0105, \u017ce po\u0142\u0105czenie budynku z sieci\u0105 jest bezpieczne i zgodne z wymaganiami centrum danych. Tradycyjny, a jednak specjalnie zaprojektowany transformator dla centr\u00f3w danych wykonuje ci\u0119\u017ck\u0105 prac\u0119 izolacji adaptacji napi\u0119cia i ochrony przed skokami napi\u0119cia, funkcji, kt\u00f3rej \u017caden inny urz\u0105dzenie elektryczne nie mo\u017ce wykona\u0107, zw\u0142aszcza na skal\u0119 dziesi\u0105tek do setek megawat\u00f3w.<\/p>\n<p>Dobrym przyk\u0142adem jest rack zasilaj\u0105cy w bocznej obudowie, o kt\u00f3rym wspomnia\u0142 <a href=\"https:\/\/www.ti.com\/about-ti\/newsroom\/news-releases\/2025\/ti-teams-with-nvidia-to-bring-efficient-power-distribution-to-ai-infrastructure.html?utm_source=chatgpt.com\" rel=\"noopener\">Texas Instruments<\/a>\u00a0kt\u00f3ry napisa\u0142, \u017ce dla racka o mocy 1 MW waga miedzi przy danym napi\u0119ciu 48 V by\u0142aby prawie nie do zniesienia (450 funt\u00f3w miedzi). Dlatego przej\u015bcie NVIDIA na 800 HVDC jest przekonuj\u0105ce.<\/p>\n<p>Inny blog NVIDIA wspomnia\u0142, \u017ce <a href=\"https:\/\/blogs.nvidia.com\/blog\/gigawatt-ai-factories-ocp-vera-rubin\/\" rel=\"noopener\">nowa architektura NVIDIA 800 V DC<\/a> zmniejszy straty konwersji, zmniejszy wymagania przestrzenne oraz zu\u017cycie miedzi zwi\u0105zane z elektronik\u0105.<\/p>\n<p>Te zmniejszone straty konwersji nie oznaczaj\u0105, \u017ce znaczenie tradycyjnych transformator\u00f3w zmniejszy si\u0119. Przeciwnie, u\u017cycie dw\u00f3ch du\u017cych transformator\u00f3w niskocz\u0119stotliwo\u015bciowych pozostaje takie samo w front-endzie, aby zintegrowa\u0107 tradycyjn\u0105 sie\u0107 i zapewni\u0107 bezpieczne zasilanie magistrali wysokiego napi\u0119cia DC.<\/p>\n<p><a id=\"mdnTags3\" class=\"mdnTags\" name=\"mdn3\" data-index=\"3\"><\/a><\/p>\n<h2><span class=\"ez-toc-section\" id=\"Where_Daelim_Transformer_Adds_Current_Value\"><\/span>Gdzie transformator Daelim dodaje warto\u015b\u0107<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Daelim Transformer ma dobrze ugruntowany projekt i zak\u0142ad produkcyjny transformator\u00f3w dystrybucyjnych w USA. Obs\u0142uguj\u0105 sektory u\u017cyteczno\u015bci publicznej, produkcji energii i przemys\u0142u, w tym du\u017cych centr\u00f3w danych, kt\u00f3re zasilaj\u0105 obecne trendy AI. Bior\u0105c pod uwag\u0119 wdro\u017cenie 800 HVDC przez NVIDIA, Daelim Transformer b\u0119dzie odgrywa\u0142 wa\u017cn\u0105 rol\u0119 w warto\u015bci dodanej w projektowaniu i rozwoju niestandardowych transformator\u00f3w elektrycznych.<\/p>\n<p><a id=\"mdnTags4\" name=\"mdn4\" data-index=\"4\"><\/a><\/p>\n<h3 style=\"margin-top: 13px; margin-bottom: 5px; text-align: left;\"><span class=\"ez-toc-section\" id=\"Medium_voltage_step_down_transformers\"><\/span>Transformatory \u015bredniego napi\u0119cia do obni\u017cania napi\u0119cia<img decoding=\"async\" title=\"Transformatory \u015bredniego napi\u0119cia do obni\u017cania napi\u0119cia\" src=\"\/media\/115\/Medium-voltage-step-down-transformers.webp\" alt=\"Transformatory \u015bredniego napi\u0119cia do obni\u017cania napi\u0119cia\" \/><span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Transformator \u015bredniego napi\u0119cia zredukowany, zaprojektowany i opracowany przez Daelim Transformer, zostanie wykorzystany w stacji transformatorowej centrum danych. Ten transformator przekszta\u0142ci sie\u0107 11 do 13 kV na ni\u017csze napi\u0119cie AC, kt\u00f3re b\u0119dzie dostosowane do pomieszcze\u0144 prostownik\u00f3w\/UPS. Te specjalnie zaprojektowane transformatory stanowi\u0105 fundament \u0142a\u0144cucha od sieci do centrum danych i umo\u017cliwiaj\u0105 p\u00f3\u017aniejsze przekszta\u0142cenie do HVDC.<\/p>\n<p><a id=\"mdnTags5\" name=\"mdn5\" data-index=\"5\"><\/a><\/p>\n<h3><span class=\"ez-toc-section\" id=\"Harmonic_mitigation_and_custom_winding_design\"><\/span>Ograniczanie harmonicznych i projektowanie indywidualnych uzwoje\u0144<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>W przypadku du\u017cego i g\u0119sto zaludnionego centrum danych, Daelim Transformers mo\u017ce zaprojektowa\u0107 i zbudowa\u0107 transformator o specjalnej konfiguracji rdzenia i uzwojenia, kt\u00f3ry mo\u017ce obs\u0142u\u017cy\u0107 harmoniczne prostownik\u00f3w. To sprawia, \u017ce bie\u017c\u0105ca praca i wiedza Daelim s\u0105 niezwykle cenne w dostarczaniu transformator\u00f3w istotnych dla etapu konwertera zasilaj\u0105cego magistral\u0119 HVDC.<\/p>\n<p><a id=\"mdnTags6\" name=\"mdn6\" data-index=\"6\"><\/a><\/p>\n<h3><span class=\"ez-toc-section\" id=\"Reliability_and_Serviceability\"><\/span>Niezawodno\u015b\u0107 i mo\u017cliwo\u015b\u0107 serwisowania<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Obecne centra danych, a zw\u0142aszcza te, kt\u00f3re zasilaj\u0105 du\u017ce modele AI, wymagaj\u0105 czasu pracy. Daelim Transformers oferuje projekty, kt\u00f3re zapewniaj\u0105 MTBF, solidne systemy ch\u0142odzenia (ONAF lub KNAF) oraz modu\u0142ow\u0105 infrastruktur\u0119 serwisow\u0105 z minimalnymi zak\u0142\u00f3ceniami.<\/p>\n<p>Zatem, podczas gdy rozmowa dotycz\u0105ca 800 HVDC skupia si\u0119 g\u0142\u00f3wnie na konwerterach, systemach dystrybucji energii na poziomie magistrali i szaf, standardowa infrastruktura transformator\u00f3w elektrycznych pozostaje solidnie na swoim miejscu i to w tym zakresie Daelim Transformers jest ekspertem i odgrywa swoj\u0105 kluczow\u0105 rol\u0119 w najlepszy mo\u017cliwy spos\u00f3b.<\/p>\n<p><a id=\"mdnTags7\" class=\"mdnTags\" name=\"mdn7\" data-index=\"7\"><\/a><\/p>\n<h2><span class=\"ez-toc-section\" id=\"Transition_Toward_Solid-State_Transformers_SSTs\"><\/span>Przej\u015bcie na transformatory p\u00f3\u0142przewodnikowe (SST)<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Architektura NVIDIA jasno pokazuje, \u017ce transformatorzy p\u00f3\u0142przewodnikowi b\u0119d\u0105 kluczowym elementem zasilania centr\u00f3w danych przysz\u0142o\u015bci. Ich publikacja wykaza\u0142a, \u017ce 13,8 kV jest przekszta\u0142cane bezpo\u015brednio do 800 V DC za pomoc\u0105 SST oraz prostownik\u00f3w przemys\u0142owych.<\/p>\n<p>Eliminuj\u0105c tym samym potrzeb\u0119 wielu krok\u00f3w konwersji AC\/DC i DC\/DC. Celem jest uproszczenie \u0142a\u0144cucha konwersji, poprawa wydajno\u015bci o 5 % w stratkach end-to-end oraz zmniejszenie koszt\u00f3w konserwacji o a\u017c 70 %.<\/p>\n<p>SST \u0142\u0105czy elektronik\u0119 do konwersji mocy o wysokiej cz\u0119stotliwo\u015bci z izolacj\u0105 magnetyczn\u0105 przy wy\u017cszej cz\u0119stotliwo\u015bci i oferuje nast\u0119puj\u0105ce zalety.<\/p>\n<ul>\n<li>Dwukierunkowa operacja, kt\u00f3ra pomaga w braku przechowywania magnes\u00f3w na miejscu i poprawia kontrol\u0119 nad systemem oraz procesem.<\/li>\n<li>Wy\u017csza cz\u0119stotliwo\u015b\u0107 prze\u0142\u0105czania, kt\u00f3ra redukuje rozmiar magnes\u00f3w i tak\u017ce poprawia kontrol\u0119 nad systemem oraz procesem.<\/li>\n<li>Te transformatory s\u0105 bardziej zwarty, inteligentne bloki mocy, kt\u00f3re lepiej nadaj\u0105 si\u0119 do system\u00f3w zasilania w mezzaninie lub w szafach danych.<\/li>\n<\/ul>\n<p>Wa\u017cne jest, aby zauwa\u017cy\u0107, \u017ce SST-y jeszcze nie zast\u0105pi\u0142y ani nie wypar\u0142y du\u017cych transformator\u00f3w niskiej cz\u0119stotliwo\u015bci w pierwszym etapie. SST-y zast\u0105pi\u0105 transformator po\u015bredni lub modu\u0142y prostownicze w miar\u0119 rozwoju dojrza\u0142o\u015bci projektu, koszt\u00f3w i skalowalno\u015bci.<\/p>\n<p>Innymi s\u0142owy, dwa pierwsze tradycyjne etapy transformator\u00f3w, kt\u00f3re s\u0105 z sieci do AC i z AC do prostownika, nadal b\u0119d\u0105 funkcjonowa\u0107 w kr\u00f3tkim okresie, szczeg\u00f3lnie w wi\u0119kszych blokach zasilaj\u0105cych centr\u00f3w danych. Tymczasem SST b\u0119d\u0105 coraz cz\u0119\u015bciej wykorzystywane na poziomie szaf.<\/p>\n<p><a id=\"mdnTags8\" class=\"mdnTags\" name=\"mdn8\" data-index=\"8\"><\/a><\/p>\n<h2><span class=\"ez-toc-section\" id=\"Conclusion\"><\/span>Wnioski<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p class=\"p\" style=\"text-align: left;\"><img decoding=\"async\" src=\"\/media\/115\/USA-DAELIM-TRANSFORMER.webp\" \/><br \/>\nDaelim Transformer pozostaje zaufan\u0105 mark\u0105 w bran\u017cy produkcji transformator\u00f3w elektrycznych i b\u0119dzie nadal wiarygodnym \u017ar\u00f3d\u0142em jako\u015bciowych us\u0142ug w tych kluczowych etapach. Z dziesi\u0105tkami wysoko wykwalifikowanych i do\u015bwiadczonych in\u017cynier\u00f3w energetyki, kt\u00f3rzy pracuj\u0105 w dziedzinie produkcji transformator\u00f3w od dziesi\u0119cioleci, Daelim mo\u017ce pom\u00f3c Twojemu centrum danych w sprawnym wdro\u017ceniu i implementacji architektury NVIDIA 800 HVDC.<\/p>\n<p>Mo\u017cesz <a href=\"https:\/\/www.daelimtransformer.com\/pl\/contact.html\">skontaktuj si\u0119 z nami, <\/a>dzisiaj, aby rozpocz\u0105\u0107 dyskusje na temat niestandardowych rozwi\u0105za\u0144 transformatorowych i innego wsparcia in\u017cynieryjnego potrzebnego do pe\u0142nej integracji systemowej system\u00f3w NVIDIA i ich zapotrzebowania na moc.<\/p>\n<\/div>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>As the world adopts AI for its day-to-day tasks, the AI workload scales dramatically. The data centers powering AI are confronted with skyrocketing power demand that moves from the current hundreds of kW to a few MW in very short order. A shift is needed in how these AI data centers are powered and how [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":7998,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[279],"tags":[],"class_list":["post-7997","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articles-news"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.daelimtransformer.com\/pl\/wp-json\/wp\/v2\/posts\/7997","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.daelimtransformer.com\/pl\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.daelimtransformer.com\/pl\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.daelimtransformer.com\/pl\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.daelimtransformer.com\/pl\/wp-json\/wp\/v2\/comments?post=7997"}],"version-history":[{"count":0,"href":"https:\/\/www.daelimtransformer.com\/pl\/wp-json\/wp\/v2\/posts\/7997\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.daelimtransformer.com\/pl\/wp-json\/wp\/v2\/media\/7998"}],"wp:attachment":[{"href":"https:\/\/www.daelimtransformer.com\/pl\/wp-json\/wp\/v2\/media?parent=7997"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.daelimtransformer.com\/pl\/wp-json\/wp\/v2\/categories?post=7997"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.daelimtransformer.com\/pl\/wp-json\/wp\/v2\/tags?post=7997"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}