Pad Mounted Transformer for BESS System 4.0 MVA in Riverside County, California

Pad Mounted Transformer for BESS System

Today, Daelim Transformer is proud to introduce a pad-mounted transformer for a 4.0 MVA Battery Energy Storage System (BESS) project located in Riverside County, California.

This pad-mounted transformer is specifically designed for deployment at a Battery Energy Storage power generation facility. Its robust design is engineered to withstand harmonic voltages and currents emanating from inverters, transient over-voltages caused by switching surges and faults, and the significant variations in transformer loading commonly encountered in BESS projects. The transformer is meticulously crafted to comply with the specifications outlined in the California Electrical Code Article 450.

Contact Daelim Transformer

In this project, the pad mounted transformer will be employed in a step-down configuration, further enhancing its adaptability and efficiency within the energy storage system. Daelim Transformer remains committed to delivering cutting-edge solutions that meet the unique demands of modern energy storage facilities.

BESS Transformer Gauges
BESS Transformer Gauges
BESS Transformer Package
BESS Transformer Package
BESS Transformer Production
BESS Transformer Production
Key Technical Specifications

Key Technical Specifications

  • Transformer Type: Three Phase Transformer - Pad-Mounted
  • Capacity: 4000 kVA(4 MVA)
  • Cooling Class: ONAN (Oil Natural, Air Natural)
  • Oil Type: Mineral
  • Temperature Rise: 65°C (High thermal capacity paper on all windings)
  • Frequency: 60 Hertz
  • Rated Voltages:
  • Primary Voltage Winding (H): 12.47 kV
  • Secondary Voltage Winding (X): 34.5 kV
  • Impedance at Base Capacity Rating: 5.75%
  • Service Conditions
  1.  Ambient Temperature Range -40°C to 50°C
  2. Altitude above Sea Level <3,300 ft
Get Price

Daelim Transformer Solution

Features and Design Highlights4 mva pad mounted transformer external compartments

  • Electrostatic Shield: Our transformer is engineered to withstand harmonic voltages, transient over-voltages, and dynamic load variations inherent in BESS projects, ensuring uninterrupted power delivery.
  • Versatile Voltage Operation: Capable of operating within a +/- 10% voltage range, our transformer adapts to varying energy demands, providing flexibility and efficiency.
  • Tap Changer: Located on the High Voltage Winding with five taps at 2.5%.
  • External Compartments: Equipped with Nitrogen filling plug, Dial type thermometer, Vacuum/pressure gauge, Liquid level gauge, and accessible Oil Sampler/Drain Valve.
  • Doors: Each compartment features independent auto-latching three-point latching systems, resistant to weather elements.

Learn more about Transformer Solutions For Energy Story

Compartment Details

Compartment Details

12.47 kV Compartment

  • Loop feed bushings for termination with 600 Amp dead break elbows conforming to ANSI C57.12.26 standards.
  • Dead front construction, expulsion type fuses, and NEMA 2-hole tank ground. To address the issue of excessive current, engineers opted for protection by employing six Bay-O-Net fuses.

34.5 kV Compartment

  • Similar specifications to the 12.47 kV compartment conforming to ANSI C57.12.26 standards.

Compartment Location

  • High-voltage and low-voltage compartments are located on one side of the transformer tank, separated by a vertical steel barrier.
Send Inquiry Now

Reading More About 4 MVA Pad Mounted Transformer

Finish and Coating

  • ANSI 61 light gray protective coating, resistant to corrosion. Touch-up paint provided.

Sectionalizing Oil Immersed Load Break Primary Switches

  • Ratings: 38 kV and 300 Amps
  • Design: Two-position, gang-operated, rotary, permanently attached, and hook stick operable on both incoming and outgoing sides.

Factory Tests

  • Daelim Transformer commits to conducting comprehensive factory tests following ANSI/IEEE C57.12.90 standards. These include resistance measurements, polarity and phase relation, ratio, no-load and load losses, impulse tests, dissolved gas in oil analysis, insulation power factor test, and oil test.

You may enjoy: Do You Know How To Do a Transformer Test?

Delivery Commitments

  • Post Factory Acceptance Test (FAT), Daelim Transformer pledges to submit electronic test reports within three days. Within two months of order placement, the company will provide the client with all relevant documents, including Outline Drawings, Nameplate drawing, Schematic and wiring diagrams, and product data sheets.

Daelim Transformer - Elevating BESS Solutions

Choose Daelim Transformer for your energy storage projects. There are professional & experienced engineering team who will provide you with the best transformer solutions and options. Daelim transformer served more than 100+ BESS projects and more than 500MW+ with its qualified & UL listed transformer within lead time below 30 weeks for most projects.

Click Here to Check more of Daelim Transformer's Projects

Quote Now


Please Write your message, ask for price, we will reply you soon, thanks

We use cookies on our website to give you the most relevant experience by remembering yourpreferences and repeat visits. By clicking "Accept All", you consent to the use of ALL the cookies.However. "Privacy Preferences".

Disagree I Agree