150 kva Pad Mounted Transformer


  • Primary Voltage Ratings: 34.5-19.92/13.8-7.957/13.2-7.62/12.47-7.2 or others
  • Secondary Voltage Ratings: 208GrdY/120;416GrdY/240,480GrdY/277,/600GrdY/347,220y/127,480V,415v,600v or others
  • H.V. TAP RANGE: ±2×2.5% or others
  • CONNECTION TYPE: Dyn11/YNyn0 or others
  • TYPE: Loop feed/Radial feed
  • BIL: 30-125 kV
  • Standards: IEEE/ANSI, DOE, CSA
  • Application: Industry, Renewable energy, EV charging, Utility
  • Power Rating: 150 kVA
  • Certificate: UL cUL CSA

150kva pad-mounted transformer design and production meet various international standards, such as ANSI, CSA, DOE, NEMA, IEEE, etc. Daelim's 150 kVA pad mounted transformer with UL, CSA, and IEEE certificates.


Quote Now
None

150 kVA pad-mounted transformer Certificate

Daelim has 20 years of experience in designing and producing transformers. At the same time, it also has 20 years of experience in international transformer projects. The 150kVA Pad Mounted Transformer with Ul/Cul, CSA certificate.

150kva transformer ul listed


150kVA Pad Mounted Transformer types


Daelim designs and produces: 150kVA loop feed pad mounted transformer, 150 kVA radial feed pad mounted transformer. Can meet U.S. DOE efficiency value.

 

150 kVA Pad Mounted Transformer HV and LV150 kva pad mount transformer

150kva pad-mounted transformer can be designed as single voltage or dual voltage. BIL from 40 to 150.

150 kVA pad mounted single voltage:

2400V, 4160V, 4800V, 7200V, 7620V, 12000V, 12470V, 13200V, 13800V, 16340V;

 

 

150kVA pad mounted transformer dual voltage:

4160GrdY/2400,12470GrdY/7200, 13200GrdY/7620, 13800GrdY/7970, 22860GrdY/13200, 23900GrdY/13800, 24940GrdY/14400, 34500GrdY/19920.

 

Learn more about pad transformers:3 Phase Pad Mounted Transformer-Daelim Belefic

 

150 kVA Pad Mounted Transformer Specification

Three Phase Transformer, Pad Mount 150 kVA 14400Delta:120GrdY/208V
DATA UNIT Offered
Supplier …. Beijing Daelim
Model …. ZGS11-H-150/14.4
Country of origin …. CHINA
Standard manufacturing and testing …. IEEE Std C57.12.00 IEEE Std. C57.91                                                             CAN/CSA C227.4
Features 
Type   Loop feed pad mount
Installation   Outdoor
HV V 14,400Delta
LV V 120GrdY/208V
Rated Frequency Hz 60
Cooling System   ONAN
Number of winding   2
Number of phase   3
Losses
No load losses at rated voltage and rated frequency on the principal tap W 337
Load loss at rated voltage W 875
Vector Group   Dyn11
High voltage electrical characteristics of transformers and assembled load break terminals
Insulation class kV 15
BIL kV 95
Low voltage
Insulation class kV 1.2
BIL kV 30
Total Dimensions
Height mm 1750
Depth mm 1250
Width mm 1480

 

150 kVA Pad Mounted Transformer Weight

150kva pad mounted transformer with a total weight of about 2500kg. The table below is the specific weight of a 14.4kV 150 kVA pad mount transformer. Depending on the voltage, the weight of the 150kva transformer will be somewhat different.

Weight
Oil L 750
Total kg 2400

Learn more about Pad Mounted Transformer

150 kVA Pad Mounted Transformer Accessories

150kva pad mounted transformer accessories

Accessories Including
Lifting lug
Hinged door
Parking stand bracket
Flip top cover
Removable tamper-proof channel
LV plate
LV bushing
Pressure relief valve
Drain Valve
Ground Strap cooper
15KV insulation class HV bushing
Ground bar
Nameplate
Brass plug
ELSP fuse
LB Switch ON/OFF
Tap changer
15KV Insert with dust cap
CEA ground bracket assy
Thermometer
Oil level gauge
Grounding pads
ELSP fuse

 

150 kVA Pad Mounted Transformer Package

150kva pad mounted transformer package
Daelim 150kva pad mount transformers use the packaging method of wooden cases and wooden pallets.


150 kVA Pad Mounted Transformer Quality and Tech Control

The DAELIM factory has strict technical and quality control to ensure each transformer's reliable, safe, and electrical performance.

Down load: Daelim Tech Control

 

Click here to check Daelim international pad-mounted transformer projects!

Related Article


Pad Mounted Transformer Project Cases

3750kVA Primary 13.8kV, Secondary:0.415kV Loop-feed Pad-mounted Transformer, 12 sets for US market;

Daelim Transformer Custom 1500 kVA Pad Mounted Transformer for Canada

As a professional pad mounted transformer manufacturer & supplier, Daelim Transformer is committed to meeting standards such as ANSI/IEEE, CSA, DOE, and NEMA, offering customized solutions. Here, we present a case of a 1500 kVA pad mounted transformer tailored for the Canadian market.

1000 kVA Pad Mounted Transformers For Jamaica Market

In October 2023, Daelim Transformer successfully manufactured two units of 6 kV 1000 kVA pad mounted transformers, meeting 100% compliance with IEEE C57.12.34 and IEEE 693-2005 standards. These transformers, one step up and the other step down, were tailored for a valued customer in Jamaica. Let's delve into the details of this exceptional project.

Single Phase Pad Mounted Transformer For USA Utility

Introducing a utility transformer project tailored for the USA, located in Virginia. This utility initiative requires 215 units of single-phase pad-mounted transformers, all UL listed, including 175 units of 25 kVA and 40 units of 50 kVA. The end user's project timeline is 90 days. Adherence to IEEE standards is imperative for single-phase transformers. Additionally, the design of transformer components and markings must be customized to meet project specifications.

Pad Mounted Transformer for BESS System 4.0 MVA in Riverside County, California

Today, Daelim Transformer is proud to introduce a pad-mounted transformer for a 4.0 MVA Battery Energy Storage System (BESS) project located in Riverside County, California. The transformer is meticulously crafted to comply with the specifications outlined in the California Electrical Code Article 450.

Single Phase Pad Mounted Transformer For USA Utility

Introducing a utility transformer project tailored for the USA, located in Virginia. This utility initiative requires 215 units of single-phase pad-mounted transformers, all UL listed, including 175 units of 25 kVA and 40 units of 50 kVA. The end user's project timeline is 90 days. Adherence to IEEE standards is imperative for single-phase transformers. Additionally, the design of transformer components and markings must be customized to meet project specifications.

The Ultimate FAQ Guide to Wind Transformers-Daelim

As one of the main equipment of wind power plants, transformers have high requirements for energy saving due to the unstable output power of wind power generation, high no-load and load losses of transformers and high requirements for energy-saving of transformers

Skid Mount Transformer Solution With 3 Phase Pad Mounted Transformer Inside

Daelim Transformer's skid mount solutions with 3-phase pad mounted transformers represent a pinnacle of modern power distribution technology, catering to the stringent demands of various industries including renewable energy, mining, data centers, and transportation sectors. Their innovative design, coupled with robust performance and ease of deployment, makes them indispensable in today's rapidly evolving energy landscape. Whether for large-scale utility projects or specialized applications like electric vehicle charging infrastructure, these solutions exemplify efficiency, reliability, and adaptability in power distribution solutions.

What is a Live Front 25kv Pad Mounted and Substation Transformer Specification ?

"Live" and "Dead" are terms commonly applied to oil-filled pad-mounted transformers. "Live front" refers to the exposed end of the cable and terminals. For example, the cable can be stripped at the end and inserted into the eyebolt terminal of the porcelain bushing.

DOE
AS
GOST