31.5 MVA 115/34.5kV Power Transformer


  • Primary Voltage Ratings: 115 kV
  • Secondary Voltage Ratings: 34.5 kV
  • H.V. TAP RANGE: 115kV*+/- 16 x 0,625 %
  • CONNECTION TYPE: YNyn0d1
  • Standards: IEC
  • Application: 115lV Substation
  • Power Rating: 31.5MVA/36MVA
  • Cooling Method: ONAN & ONAF

The 31.5 MVA 115/34.5 kV Transformer is an IEC-standard, mineral oil-immersed unit designed for continuous operation. It features a robust ONAN/ONAF cooling system and includes a 32-step on-load tap changer, automatic voltage regulator, and multiple safety accessories like Buchholz relays and thermal imaging. Suitable for outdoor installation, it supports a maximum primary voltage of 123 kV and secondary voltage of 36 kV. This transformer ensures reliable performance with a temperature rise of 55/65 ºC and includes comprehensive monitoring and protection features.


Quote Now
None

Overview

Introducing the high-performance 31.5 MVA Power Transformer, engineered to meet IEC standards and specifically designed for the Philippine substation project. This transformer ensures reliable and efficient power distribution in demanding conditions.

Key Specifications:

  • Rated Power: 31.5 MVA (Continuous) / 36 MVA (Short-Term)
  • Nominal Voltage: 115 kV / 34.5 kV
  • Number of Phases: 3
  • Cooling System: ONAN/ONAF
  • Type: Mineral Oil Immersed Transformer
  • Rated Frequency: 60 Hz
  • Working Regime: Continuous
  • Primary Voltage: 115 kV
  • Maximum Service Primary Voltage: 123 kV
  • Primary Winding: Wye with Neutral
  • Tapping Range: +/- 16 x 0.625%
  • Secondary Voltage: 34.5 kV
  • Maximum Service Secondary Voltage: 36 kV
  • Secondary Winding: Wye with Neutral
  • Compensation Winding Voltage (Tertiary): 15 kV (Compensation Only, Not Accessible)
  • Maximum Service Tertiary Voltage: 17.5 kV
  • Compensation Winding: Delta
  • Connection Group: YNyn0d1
  • BIL: 550/170/95 kV
  • Coil Material (HV/LV): Copper
  • Coil Material (Compensation Winding): Copper
  • Isolation Material: Mineral Oil
  • Conservator Tank: Included
  • Temperature Class: E (120 ºC)
  • Temperature Rise (Oil/Coil): 55/65 ºC
  • Altitude: <3000 feet
  • Ambient Temperature: Max 45 ºC, Min 5 ºC
  • Location: Outdoor
  • Color: Gray, RAL 7035
  • Bushing Location (HV/LV): Top Cover

Accessories:

  • On Load Tap Changer (OLTC): 32 Steps Huaming or Equivalent
  • Tap Position Indicator
  • Automatic Voltage Regulator (AVR)
  • OLTC Conservator
  • HV Condenser Bushing
  • LV Condenser Bushing
  • LV Porcelain Bushing
  • NEMA Connectors
  • Buchholz Relay with Two Contacts
  • Oil Conservator System with Membrane
  • Membrane/Bag Rupture Relay
  • Pressure Relief Valve with Two Contacts
  • Sudden Pressure Relay
  • Thermal Imaging Relay
  • Shutter Valve
  • Dehydrating Breather - Silica Gel (Main Tank)
  • Dehydrating Breather - Silica Gel (OLTC)
  • Magnetic Oil Level Indicator with Two Contacts (Main Tank)
  • Magnetic Oil Level Indicator with Two Contacts (OLTC)
  • Transformer Monitor Temperature and Parallelism (SEL 2414 or Equivalent)
  • Temperature Sensor PT100
  • Protection Type CTs (HV and LV)
  • Metering CTs (HV and LV)
  • Thermal Imaging CTs (HV and LV)
  • OLTC CTs
  • Fans
  • Accessory Connection Box + Forced Ventilation Kit
  • Removable Radiators
  • Bidirectional Wheels
  • Nameplate with Essential Data
  • Oil Filling and Draining Valves (Main and Conservator Tanks)
  • Oil Sampling Device
  • Grounding Terminals
  • Lifting Lugs and Connections for Haulage

Contact Us

For detailed specifications, further inquiries, or to request a quotation, please reach out to Daelim Transformer directly. We are committed to providing you with the highest quality transformers tailored to your needs.

Related Article


230 kV Three Phase Power Transformer For USA Market

In 2023, Daelim Transformer designed and manufactured a cutting-edge 230 kV three-phase power transformer for a client in Nevada, USA. The client recently shared installation and operational photos, showcasing the successful deployment of this remarkable transformer. Let's delve into the specifics of this transformer project!

Canadian 69 kV Substation Transformer Project

Today, we are excited to present a case study on a 69 kV substation transformer project by Daelim Transformer. Our Canadian client required a step-down transformer for their substation to connect with the hydroelectric grid in Quebec.

20MVA Power Transformer for the United States

This project involves the development of a 20 MVA three-phase power transformer tailored for the United States market. The primary voltage is 24.94kV, and the secondary voltage is 4.16kV, indicating it functions as a step-down transformer. The design and production fully comply with IEEE C57.12.00 standards and have passed third-party UL team testing. All accessories also adhere to IEEE standards. FR3 vegetable oil serves as the insulating liquid for the transformers.

13.8 kV 10.5 MVA Substation Transformer for Ecuador

A customer from Ecuador contacted Daelim Transformer for a 10.5MVA substation transformer (13.8kV high voltage, 2.4kV low voltage). Daelim Transformer provided a customized solution, conducted virtual factory tours, ensured rigorous quality control via video inspections, and offered post-delivery online training and ongoing support, fostering a successful partnership.

Pad Mounted Transformer For High Voltage Substation

FWS commissioned Daelim Transformer to design and manufacture a new high voltage substation for the Richardson International Canola Crush facility expansion in Yorkton, SK. The project required two specially designed top-in pad-mounted transformers, one 2 MVA and one 5 MVA. Unable to meet the delivery deadline, local North American suppliers led FWS to choose Daelim Transformer for their capacity and quality. The transformers were successfully produced and delivered within 16 weeks and are now operating safely.

1500 kVA Transformer for Australian Mining Project

Introduce the 1500 kVA transformer tailored for Australian mining projects. The transformer operates in a three-phase configuration, with a total of four units deployed. Notably, its primary voltage stands at 11kV, while the secondary voltage is 1kV. Characterized by its compact size, emphasis on safety, and unwavering reliability, this transformer is meticulously designed and manufactured to meet the stringent requirements outlined in AS 60076 and AS efficiency value standards.Let's delve into the key features and specifications of this essential solution.

DOE
AS
GOST