1,000+ Electrical Transformers (7.2–34.5 kV, 25–3000 kVA) — UL Evaluated, Certificate of Compliance Available — In Stock & Ready to Ship from Houston, CA & Florida. Contact Us Today!  

2500 kVA Substation Transformer

Additional information

Primary Voltage Ratings: 24.94kV( other you need)

Secondary Voltage Ratings: 480GrdY/277V( other you need)

CONNECTION TYPE: Dyn1( other you need)

TYPE: Substation

BIL: 30-125kV

Standards: CSA C88-16, IEEE C57

Application: Distribution system, EV charging, BESS,Industry, Renewable energy

Power Rating: 2500 kVA, 2.5 MVA

Certificate: UL, cUL, CSA

Customizable with cover-mounted or side-mounted bushings. Complies with UL/cUL, CSA standards, and third-party test reports. At Daelim Transformer, we understand that every project comes with unique requirements. That’s why we offer customizable transformers, allowing you to adjust voltage, capacity, and parameters to perfectly align with your needs.The 2500 kVA substation transformer is specifically designed for the Canadian distribution system and is compliant with the CSA C88-16 standard, which is the applicable standard in Canada for distribution transformers. This transformer utilizes a vegetable oil-based insulating liquid with a low ignition point, which offers improved fire safety compared to traditional mineral oil. The use of vegetable oil as the insulating liquid is environmentally friendly and helps reduce the overall environmental impact of the transformer. The transformer employs the KNAN (K) cooling method, which stands for “Natural cooling with Air Natural.” This means that the transformer relies on natural convection and ambient air circulation for cooling, without the use of any forced cooling mechanisms such as fans.

Daelim Transformer is a professional manufacturer of transformers with extensive project experience in North America. Our team is proficient in IEEE, CSA, DOE, NEMA, and other standards, as well as local laws and regulations. We export thousands of transformers to North America every year. Daelim’s UL-listed transformers are up to 44kV, making us the transformer manufacturer with the most UL certificates in China.

2500 kVA (2.5 MVA) Substation Transformer Specifications
HV24,940DELTAWidth(mm)2400
LV480GrdY/277VLength(mm)2200
Applied Standard CSA C88-16Height(mm)2060
MethodKNANOil weight1350L
Power rating2500 kVA (2.5 MVA)Total weight5450kg
Vector GroupDyn1Impedance5.75%
Winding materialALUMINIUMEfficiency99.37%
No. OF TAP POSITION5ColorANSI Grey 61

You may enjoy:  2500 kVA Pad Mounted Transformer

Contact Daelim Transformer for special requirements

Daelim Transformer has designed the 2500 kVA substation for a Canadian customer. The transformer is equipped with instruments such as a pressure relief device, liquid level indicator, thermometer, and more. These instruments are conveniently installed within a gauge that features a door, allowing easy access for monitoring and maintenance purposes.

 

2500 kVA Transformer Accessories

2500 kVA Transformer Accessories

The SL-2500-24.94-0.48 transformer is designed with a primary voltage of 24.94 kV in a delta configuration and a secondary voltage of 480 GrdY/277. It has a capacity of 2500 kVA. This transformer utilizes an environmentally friendly insulating liquid, specifically a degradable vegetable oil with a low flash point. It is classified as a KNAN transformer.

The main fittings of the SL-2500-24.94-0.48 transformer are the following:

HV BUSHING (25kV 4 Hole )3PRESSURE RELIEF DEVICE1
LV BUSHING 8 Hole4NAME PLATE(STAINLESS STEEL)1
RADIATORS4LIQUID LEVEL INDICATOR1
HANDHOLE2LIFTING HOOK FOR COMPLETE TRANSFORMER4
THERMOMETER1THROAT FLANGE,HV1
POCKET1THROAT FLANGE,L.V1
1”UPPER FILL VALVE1BASE WELDED TO TANK1
EXTERNAL 1DRAIN VALVE1LIFTING EYE FOR ACTIVE PART WITH TANK COVER4
DRAIN VALVE GUARD1GROUND PAD ON TANK WALL4
VACUUM PRESSURE GAUGE1TAP CHANGER1
TERMINAL BLOCK1INSTRUMENT BOX1

Contact Daelim Transformer

2500 kVA (2.5 MVA) Substation Transformer Drawing

The SL-2500-24.94-0.48 transformer is specifically designed for the Canadian market and follows the standards set by the CSA (Canadian Standards Association). It features a side mount design for both the high voltage and low pressure components. The low voltage ground configuration is utilized.

For the connections, the transformer uses the Dyn1 configuration, which refers to a Delta (Δ) primary winding and a Wye (Y) secondary winding connection with neutral brought out. This configuration is commonly used for three-phase transformers and offers a balanced power distribution.

The instrumentation of the transformer is located inside a sealed enclosure, ensuring the protection and safety of the internal components.

Get Price

2500 kVA (2.5 MVA) Substation Transformer Drawing

2500kVA Transformer

2500kVA-Transformer-Workshop

2500kVA-Transformer-Workshop

2000 kVA Transformer Package

2000 kVA Transformer Package

2500 kVA Substation Transformer

2500 kVA Substation Transformer

Other 2500 kVA Substation Transformer

34.5kV 2500 kVA Transformer

34.5kV 2500 kVA Transformer

The SL-2500(3000)kVA/34.5/0.48 transformer is designed in compliance with the CSA C88 standard. It employs the KNAN/KNAF cooling method, providing two different power ratings based on the cooling configuration.

Under normal operating conditions with natural cooling (KNAN), the transformer has a capacity of 2500kVA. However, when the fan is activated, enabling forced air cooling (KNAF), the power rating increases to 3000kVA.

The main technical parameters of the SL-2500(3000)kVA/34.5/0.48 transformer are following:

HV 34500VWidth(mm)86.6 inch
LV480GrdY/277VLength(mm)104.4 inch
Applied Standard CSA C88-16Height(mm)85 inch
MethodKNAN/KNAFOil weight1750KG
Power rating2500/3000 kVATotal weight6600KG
Winding materialALUMINIUMRated Frequency60Hz
Vector GroupDyn1No. OF TAP POSITION5

Learn more about Substation Transformer

Send Inquiry Now

13.8 kV 2500 kVA Transformer

The SL-2500(2800)kVA/13.8/0.24 transformer is designed in compliance with the IEEE standard. It operates with a primary voltage of 13800V and a secondary voltage of 240V. The transformer has a K-factor value of 13, indicating its ability to handle non-linear loads effectively.

In terms of design, both the high and low voltage sides of the transformer adopt a side-mount layout. Additionally, the transformer is equipped with a sealed cover, ensuring protection and containment of the internal components.

  • Phase: 3Ø
  • Capacity: 2500kVA/2800kVA
  • Rated Primary Voltage: 13800V
  • Rated Secondary Voltage: 240V
  • Rated Primary Current: 104.6A
  • Rated Secondary Current: 6014.1A
  • Core Type: Wound
  • Vector Group: Dyn 11
  • Oil Volume: 2328L
  • Total Weight: 6927 kg
  • Insulation Primary Level: LI/AC: 95/34 kV
  • Insulation Secondary Level: LI/AC: 30/10 kV
  • Applied Standard: “IEEE Std C57.12.00, IEEE Std C57.12.36”

You may enjoy: Pad Mounted Transformer
Get Price

13.8 kV 2500 kVA Transformer

Quote Now

Please Write your message, ask for price, we will reply you soon, thanks

Right Sidebar Form

Get A Quote

Contact Us