Primary Voltage Ratings: 115kV
Secondary Voltage Ratings: 13.8kV
H.V. TAP RANGE: 115kV ± 8 × 0.625%
CONNECTION TYPE: YNd1
TYPE: On load tap changer power transformer
BIL: 450/110kV
Standards: IEEE
Application: New Energy
Power Rating: 20,500/27,200/35,000kVA
Cooling Method: ONAN/ONAF1/ONAF2
The 35MVA 115kV 3 Phase Power Transformer, manufactured in December 2024, is a state-of-the-art electrical device designed to serve critical applications in renewable energy projects. Delivered to a key client in California, USA, this transformer is a key component in advancing clean energy solutions. It is built to meet the highest standards of performance, reliability, and energy efficiency, ensuring optimal operation in both conventional and renewable energy systems.
Contact Daelim Transformer for special requirements
| 115kV 35MVA Transformer Technical Specifications | |
| RATED POWER | 20.5/27.2/35 MVA |
| RATINGPRIMARY VOLTAGE | 115 kV |
| SECONDARY VOLTAGE | 13.8 kV |
| FREQUENCY | 60Hz |
| VECTOR GROUP | YNd1 |
| WINDING MATERIAL | COPPER |
| LOAD LOSS | 166.9KW |
| NO LOAD LOSSES | 19.86KW |
| IMPEDANCE VOLTAGE | 15.01% |
| ALTITUDE | ≤1260m |
| SERVICE LOCATION | OUTDOOR |
| INSULATING OIL WEIGHT | 1670 GAL |
| TOTAL WEIGHT | 102977 LBS |
| 115kV 35MVA Transformer Accessories | |
| Dissolved gas anaylzer | Nameplate |
| Oil level indicator for OLTC | Conservator for OLTC |
| Pressure sensor | HV neutral bushing |
| Sudden pressure relay | HV Surge arrester |
| LV CT box | HV Bushing |
| Oil level indicator for main tank | NEMA 4 Control Cabinet |
| HV CT box | OLTC motor drive |
| HV Neutral CT box | Manhole |
| Mercury thermometer | LV Surge arrester |
| Core grounding bushing | LV Bushing |
| Radiator | Oil temperature indicator |
| Cooling fan | Winding temperature indicator |
| On-load tap changer | Tank cover |
| Pressure relief valve | HV regulation winding |
| copper draining valve | LV winding |
| Oil sample valve | HV winding |


In the event of rapid internal gas buildup due to fault conditions, the transformer is equipped with a pressure relief valve. This system discharges excess gas, preventing excessive pressure and allowing the control room to take immediate action by triggering an automatic trip.
Both the transformer’s main body and tap changer conservator are equipped with a self-regenerating breather (Qualitrol brand). The breather uses a built-in desiccant (silica gel) that absorbs moisture and regenerates through heating, preventing moisture and air from entering the transformer. This ensures the insulation remains dry, supporting the transformer’s long-term operational stability.
Applications
The 35MVA 115kV Three-Phase Power Transformer is a cutting-edge, high-performance solution for modern power distribution systems, particularly in renewable energy sectors. With advanced materials, superior safety features, and energy-saving design, it offers high efficiency, reliability, and long service life. This product exemplifies Daelim Transformer’s commitment to delivering innovative, quality solutions to meet the demands of a sustainable energy future.
Contact us today to learn more about how the 35MVA 115kV Three-Phase Power Transformer can enhance your renewable energy projects and ensure reliable, efficient power distribution.
Please Write your message, ask for price, we will reply you soon, thanks