Single Phase Pole Mounted Transformer

Additional information

Primary Voltage Ratings: 34.5-19.92/13.8-7.957/13.2-7.62/12.47-7.2 or others

Secondary Voltage Ratings: 120-240/240-480/347/600V or others

H.V. TAP RANGE: ±2×2.5% or others

CONNECTION TYPE: Ii0,Ii6

TYPE: Conventional type/CSP type

BIL: 30-150kV

Standards: IEEE, CSA, DOE, IEC

Application: Utility, Electrical wholesales, Industry

Power Rating: 10-333 kVA

Daelim single phase pole mounted transformer with UL/cUL, CSA, SGS, and CESI certificates. Single phase transformer is an oil-immersed transformer, and there are two types of single-phase transformers: Conventional Type and CSP Type. Rating ranging from 10 kVA to 333 kVA.Daelim Transformer takes pride in its ability to provide customizable and in-stock solutions for single-phase transformers, catering to a spectrum of industry requirements. Daelim Transformer’s commitment to versatility ensures that these transformers can seamlessly adapt to specific needs, including dual-pressure systems and specialized accessories.

    Single Phase Transformer

    Daelim Transformer produces a variety of international standard single-phase pole-mounted transformers. The voltage level can reach up to 35 kV, and the power rating can reach 333 kVA.

    Thousands of Daelim Transformer’s single-phase transformers have been installed and used in the American market, providing support for hundreds of projects. We offer help and support to a large number of utilities and electrical wholesalers in the Americas

    Contact Daelim Transformer

    Single Phase Transformer

    15kVA Single Phase Transformer

    15kVA Single Phase Transformer

    Get Price

    25kVA Single Phase Transformer

    25kVA Single Phase Transformer

    More Detail

    25kVA Single Phase Transformer

    25kVA Single Phase Transformer

    More Detail

    50kVA Single Phase Transformer

    50kVA Single Phase Transformer

    Get Offer

    75kVA Single Phase Transformer

    75kVA Single Phase Transformer

    More Detail

    100kVA Single Phase Transformer

    100kVA Single Phase Transformer

    More Detail

    Single Phase Pole Mounted Transformer

     

    Single Phase Pole Mounted Transformer Certificates

    Daelim single phase pole mounted transformer has a series of certificates such as UL/cUL, CSA, and CESI. In addition, many years of market experience in North America and South America in the United States, Canada, Honduras, and other North America.

    All units meets or exceeds IEC60076, ANSI/IEEE C57.12.20,C57.12.31, CSA C2.1-06, CSA C2.2-06, NEMA, DOE2016 and etc.Pole Transformer’s design is mainly used for electrical applications such as overhead power distribution loads and light industries and lighting. Frequently applied to Electric Utility Power Distribution Systems.

    single phase pole mounted transformerul listed single phase transformer

    You may enjoy: Single Phase Pole Mounted Transformer For Guyana

    Standard Features

    You can choose high-quality mineral oils with economy; you can also choose vegetable oils that are friendly to the environment to increase fire safety and electrical performance;

    Reaching or exceeding ANSI, NEMA, CSA, DOE efficiency values and other industry standards

    –Quality System ISO 9001 certified.

    Paint system meeting or exceeding the performance of the –lEEEC57.12.28 Standard (para. 5.3 to 5.5 included), including the salt spray test.

    Lifting lugs meeting all of the requirements of the CSA C2.1-06 and CSA C2.2-06 Standard (including features to prevent sling slippage).

    Computer aided design for mechanical &electrical calculations(C.A.D.)

    Core and coils designed for an optimum Total Ownership Cost (TOC)

    Low voltage leads with embossed markings on all units with 3 LV bushings for easy reading and permanent identification on selected ratings

    Provision for surge arrester bracket, bracket available as an option

    –“Low-high-low” windings for increased short circuit strength, efficiency, and thermal strength

    Cover or sidewall mounted high voltage bushing(s) as required

    Wound core with step-lap joints for increased efficiency and lower noise levels

    Dual voltage designed to meet BIL and short circuit requirements on both connections.

    –Automatic self-resealing pressure relief valve.

    Low voltage spade or clamp type (basket) terminals as required

    Multiple cover clamps to ensure proper sealing and minimize water retention on the cover edge

    CSP type standards

    Primary protective link

    Surge arrester

    Secondary circuit breaker

    Secondary breaker operating handle with emergency overload reset

    Learn more: CSP VS Conventional Transformer: Which Is Better?

    Optional Accessories

    –Externally-operable multiple voltage switches for safe operation

    –Externally-operable tap changer switches for safe operation

    –Special designs conforming to international specifications

    –Dual voltage primary complete with externally operated voltage switch

    –Extra creep bushing

    –Surge arrester bracket

    –Drain/sampling valve

    –Filter press connections

    –Porcelain low-voltage bushings

    –Nonconductive transformer cover

    –Temperature gauge (tank size limitations apply)

    –Liquid level gauge (tank size limitations apply)

    –Pressure vacuum gauge (tank size limitations apply)

    Learn more: Telephone Pole Transformer

     

    Single Phase Transformer Details

    Single phase pole mounted transformer is a distribution-type transformer. Oil-filled single-phase overhead transformers designed and produced by Daelim are normally used for stepping utility distribution voltages (ranging from 2400 to 34500 volts) down to lower utilization voltages. Although some are used for stepping down to commercial and industrial voltages such as 277, 240/480, 2400, and 4800, most are used for stepping down to the single-phase voltage of 120/240.

    Single Phase Transformer Specifications

    The standard single phase transformer power rating is from 5-167kVA.Daelim can be customized according to your needs, the maximum capacity can reach 333kVA.The following table is the standard of single phase transformer specifications.

    250 kva single transformer333 kva single phase transformer

    If you need single phase pole mounted transformers with other capacities, please send an email to sales@daelimbelefic.com.

    Single-Phase Distribution Transformer
    Rated Power High Voltage Low VoltageW(mm)D(mm)H(mm)Weight(kg)
    5 kVA34.5kV/19.92kV
    13.8kV/7.9kV
    13.2kV/7.6kV
    12.47kV/7.2kV
    or others
    120-240V
    240-480V
    347V
    600V
    400530960115
    10 kVA430530980150
    15 kVA4805801000205
    25 kVA5005801030245
    37.5 kVA5606401080335
    50 kVA5606401130370
    75 kVA7808001170505
    100 kVA7108001230530
    167 kVA7958951335680

    Single Phase Pole Mounted Transformer Drawing

    The figure below is single phase pole mounted transformer drawings designed by Daelim Transformer for Canadian and American customers. These are 25 kVA, 50 kVA, 75 kVA, and 167 kVA pole-mounted transformers. 

    pole mounted transformer drawing

    Single Phase Transformer Types

    single phase pole mounted transformer types
    There are two types of single-phase transformers, one Conventional Type and the other CSP Type. Ratings range from 5 kVA to 167 kVA.

     

    Conventional Type

    The transformer is a cylinder-sealing structure. Each one is fixed with grounding devices, hooks, and supporting lugs that conform to ANSI standards, and or ore two high voltage bushing on the cover, low voltage bushing on the wall of the tank, and eyebolt, connecting terminals. The tap changer should be adjusted based on the instruction after the power is off.

    single phase transformer types

    CSP Type

    This type of sing-phase transformer can protect itself from thunder and lightning, short circuits, and protect the transiting and distribution line from current failure because of self-malfunction.

    Except for some similarities such as cylinder tanks, hooks, lifting lugs, grounding devices, nameplates, core, and winding with the conventional type. This type of sing phase transformer has characteristics and devices as follows:

    One or two high-voltage bushings are on the cover with a fuse.

    One or two arresters are installed on the wall of the tank, whose top end is near the voltage bushing, and connected to the bushing by a copper strip. One secondary breaker switch is above the winding inside the tank, and here are the operating handle, overload reset, and signal light.

    All units are built in accordance with IEC60076, ANSI/IEEEC57.12.20, CSA C2.1-06, CSA C2.2-06 and etc.

    csp single phase transformer

    Catalog Download

    Single Phase Transformer PDF

     

    Single Phase Pole Mounted Transformer Optional Accessory

    Surge arresterLow voltage circuit breaker
    Protective link4a/Circuit breaker emergency control
    Current-limiting fuse4b/Signal light
    Protecto-comboTap changer
    Dual voltage switchTank pressure relief

    single phase transformer optional accessory

     

    Daelim also has single phase pad mounted transformer

    Single Phase Transformer Test

    Each single phase transformer was tested in strict accordance with the latest revision of applicable ANSITM, IEEETMCSA, and NEMA with test reports available by serial number of the transformer

    Routine tests are:

    ·Leak test

    ·Polarity and phase relation

    ·Resistance

    ·No-load losses and excitation current

    ·Load losses and impedance

    ·Applied voltage

    ·Induced voltage

    ·Full wave impulse

    ·Ratio test

    Get it now: How to test a power transformer?

    Single Phase Transformer Test Report

    Single Phase Transformer Test Report
    1、Specification
    Rated Capacity15Product
    Type
    DL-15/19.92/0.24
    (0.12)
    60HZFactory Serial
    No.
    3Voltage CombinationHV(kV)19.92CurrentHV(A)0.753Angular displacementII0
    LV(kV)0.24LV(A)62.5
    2、 Measurement of voltage ratio
    Tapping PositionHV and LVThe Voltage Value of the Test
    The Grade and Accuracy: QJ35 A
    Grade 0.2
    HV(V)LV(V)HV/LV(%)
    A199202400.048
    B194220.031
    C189240.064
    D184260.033
    E179280.067
    3、 Measurement of winding resistance  (Routine)
    Tapping PositionWinding Resistance
    Measurement
    HV (Ω)LV(Ω)
    A92.48X1X2 (Ω)0.01121
    B90.23
    X2X3 (Ω)0.005759
    C87.91
    D85.64
    X1X3 (Ω)0.01653
    E83.26
    The Meter NO. and Grade of AccuracyBZC3395
    Grade 0.2
    Temperature32℃Humidity65%
    4、No-load loss and no-load current test.
    Test ItemsNo-Load Loss at 100% rated voltage WNo-Load Current %
    Measured Value530.41
    5、Load loss and Short circuit test.
    Test ItemsLoad Loss at 85°C and rated voltage WTotal Loss WShort Circuit Impedance at 85°C
    Measured Value128.5181.51.97
    6、 Applied voltage test
    Power Frequency
    withstand Voltage Test
    Test Time60 S
    The Test Voltage(kV)HV50 / LV5
    7、Induced Over Voltage Withstand Test
    Induced Over Voltage
    Withstand Test(kV)
    0.48
    8、 Insulation Resistance test
    locationInsulation Resistance( M  Ω)    at 10℃ R60
    HV-E>1500
    LV-E>1500
    9、 Other Information.
    The Active Parts
    Weight of Lifting
    The Weight of Insulation OilTotal WeightThe Temperature Rise of the
    Oil
    Oil Pressure
    12070230<65K50KV
    10、Leakage test  (Routine)
    Test methodApplied pressure(kPa)Duration(h)Residual pressure(kPa)Result
    The static pressure
    method
    202418No leakage and no
    damage
    11、 Outer inspection
    The nameplate, sign, earthing terminal, and mark of terminal meet the requirement. There is no evidence of leakage.

    Single Phase Transformer Packaging

    single phase pole mounted transformer packaging
    There are two packaging methods of single-phase transformers, one is wooden pallet packaging, and the other is wooden frame packaging.

    If it is transported by the cabinet, it is usually packed with wooden frames, which are more stable and reliable.

     

    In a 40-foot cabinet, a single-phase transformer with a capacity below 50kva can be equipped with 60 units; 75kVA single-phase transformer can be equipped with 48 units; 100 kVA single-phase transformer can be equipped with 36 units; 167 kVA single-phase transformer can be equipped with 21 units.

    100 kVA Single Phase Transformer Diagram

    100kva single phase transformer diagram

    Learn more: Ultimate Guide To Power Transformer Diagrams

    Quote Now

    Please Write your message, ask for price, we will reply you soon, thanks

    Right Sidebar Form

    Get A Quote

    Contact Us